← Back
One family attached or semi-detached
2940 LURTING AVENUE
BRONX · Pelham Gardens · BIN 2055065
💬 Discuss this project
1950Year Built
2Stories
A5Building Class
R4Zoning
1,782 sfGross Floor Area
1Units
3 Open Violations ▸FDNY Report ↗
One family attached or semi-detached · 1,950 sf lot · 0.91 FAR built · Flood zone X
Locations of Work
Mechanical
Floor 23p · 1 filing · 17 docs
Floor 13p · 1 filing · 17 docs
Basement1p · 1 filing · 17 docs
Sub-Basement3p · 1 filing · 17 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/19/2016$299K—— → —$168/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JDJ ENGINEERING, DPC201/15/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ROBERT KOCAJElectrical103/21/2026
SUPER COOL HVAC, LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JDJ ENGINEERING, D.P.C.6780201/15/2021
Building Lifecycle
All (19)Filed (2)Permit Issued (1)Signed Off (1)Violation (7)Special Inspection (8)
01/21/2021
Signed off — Alteration
FURNISH & INSTALL TWO (2) 3.75 TON MULTI-SPLIT HEAT PUMP SYSTEMS WITH NINE (9) DUCTLESS AHUS WITHIN EXIST. SEMI-ATTACHED HOME TO PROVIDE FULL BUILDING HEATING DEMAND AT 17 DEGREES OUTDOOR TEMPERATURE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00422057-I1
01/20/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jonathan Johrden
01/20/2021
Special inspection requirement — Mechanical Systems
Jonathan Johrden
01/20/2021
Special inspection requirement — Energy Code Compliance Inspections
Jonathan Johrden
01/20/2021
Special inspection requirement — Final
Jonathan Johrden
01/20/2021
Special inspection requirement — HVAC and service water heating system controls
Jonathan Johrden
01/20/2021
Special inspection requirement — Maintenance information
Jonathan Johrden
01/20/2021
Special inspection requirement — HVAC and service water heating equipment
Jonathan Johrden
01/20/2021
Special inspection requirement — HVAC insulation and sealing
Jonathan Johrden
01/15/2021
Filed — Alteration
FURNISH & INSTALL TWO (2) 3.75 TON MULTI-SPLIT HEAT PUMP SYSTEMS WITH NINE (9) DUCTLESS AHUS WITHIN EXIST. SEMI-ATTACHED HOME TO PROVIDE FULL BUILDING HEATING DEMAND AT 17 DEGREES OUTDOOR TEMPERATURE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00422057-P1
11/30/2020
Permit issued — Mechanical Systems
X00422057-I1-MS
11/03/2020
Filed — Alteration
FURNISH & INSTALL TWO (2) 3.75 TON MULTI-SPLIT HEAT PUMP SYSTEMS WITH NINE (9) DUCTLESS AHUS WITHIN EXIST. SEMI-ATTACHED HOME TO PROVIDE FULL BUILDING HEATING DEMAND AT 17 DEGREES OUTDOOR TEMPERATURE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X00422057-I1
07/25/2013
Violation issued (ECB, closed)
Construction
07/25/2013
Violation issued (ECB, closed)
Construction
07/20/2013
Violation issued (ECB, closed)
Unknown
04/19/2013
Violation issued (ECB, closed)
Construction
04/19/2013
Violation issued (HPD, open)
B
04/19/2013
Violation issued (HPD, open)
B
04/19/2013
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offSUPER COOL HVAC, LLC11/30/2020
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
01/20/2021Fire-Resistant Penetrations and JointsJonathan Johrdenspecial
01/20/2021Mechanical SystemsJonathan Johrdenspecial
01/20/2021Energy Code Compliance InspectionsJonathan Johrdenprogress
01/20/2021FinalJonathan Johrdenprogress
01/20/2021HVAC and service water heating system controls Jonathan Johrdenenergy_progress
01/20/2021Maintenance informationJonathan Johrdenenergy_progress
01/20/2021HVAC and service water heating equipment Jonathan Johrdenenergy_progress
01/20/2021HVAC insulation and sealing Jonathan Johrdenenergy_progress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Mechanical Systems2
08/25/2026X00422057-I1Request digital key ↗
08/15/2026X00422057-P1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
05/03/2016220529952Open ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature6
08/28/2026X00422057-I1Open ↗
08/28/2026X00422057-I1Open ↗
08/28/2026X00422057-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026X00422057-I1Open ↗
08/25/2026X00422057-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026X00422057-I1Open ↗
08/28/2026X00422057-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
05/03/2016220529952Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
05/03/2016220529952Open ↗
▸Safety & Tenant Protection3
▸DOB NOWTenant Protection Plan2
08/13/2026X00422057-I1Open ↗
08/13/2026X00422057-P1Open ↗
▸BISSTREET TREE CHECKLIST1
05/03/2016220529952Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/25/2026X00422057-P1Open ↗
08/25/2026X00422057-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
05/03/2016220529952Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
05/03/2016220529952Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026X00422057-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
05/03/2016220529952Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
05/03/2016220529952Open ↗