← Back
Three families
2947 BAINBRIDGE AVENUE
BRONX · BIN 2016970
💬 Discuss this project
1901Year Built
2.5Stories
C0Building Class
R5AZoning
3,100 sfGross Floor Area
3Units
Rent Stabilized10 Open Violations 7 unresolved · 3 paperwork only ▸
Three families · 5,554 sf lot · 0.56 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 32p · 1 filing · 3 docs
Floor 2
Floor 12p · 1 filing · 3 docs
Cellar3p · 2 filings · 11 docs
1 job · most recent 10/19/2020
FiledStatusContractorScope
10/19/2020CompletePOWER KEY ELECTRIC CORP.4 meters, 4 new_meters
Building Lifecycle
All (38)Filed (4)Signed Off (2)Objection (32)
08/15/2023
Signed off — Alteration
HEREWITH FILING FOR INTERIOR RENOVATION OF 3-FAMILY HOUSE AS PER, PLANS & CORRECT VIOLATIONS # 34696108L, 35507642M. NO CHANGE OF USE, EGRESS OR OCCUPANCY THIS APPLICATION. THIS JOB IS SUPERSEDING JOB# X00541840-I1
X00839852-I1
08/15/2023
Signed off — Alteration
HEREWITH FILING PLUMBING MODIFICATIONS OF 3-FAMILY HOUSE AS PER, PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY THIS APPLICATION.
X08007368-I1
05/17/2023
Filed — Alteration
HEREWITH FILING PLUMBING MODIFICATIONS OF 3-FAMILY HOUSE AS PER, PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY THIS APPLICATION.
X08007368-P1
03/07/2023
Filed — Alteration
HEREWITH FILING FOR INTERIOR RENOVATION OF 3-FAMILY HOUSE AS PER, PLANS & CORRECT VIOLATIONS # 34696108L, 35507642M. NO CHANGE OF USE, EGRESS OR OCCUPANCY THIS APPLICATION. THIS JOB IS SUPERSEDING JOB# X00541840-I1
X00839852-I1
09/26/2022
Filed — Alteration
HEREWITH FILING PLUMBING MODIFICATIONS OF 3-FAMILY HOUSE AS PER, PLANS. NO CHANGE OF USE, EGRESS OR OCCUPANCY THIS APPLICATION.
X08007368-I1
08/09/2022
Objection raised — Other
08/09/2022
Objection resolved — Addressed
01/19/2022
Objection raised — Zoning
01/19/2022
Objection resolved — Addressed
01/19/2022
Objection raised — Scope
01/19/2022
Objection resolved — Addressed
01/19/2022
Objection raised — Cost
01/19/2022
Objection resolved — Addressed
01/19/2022
Objection raised — Fire_Protection
01/19/2022
Objection resolved — Addressed
01/19/2022
Objection raised — Other
01/19/2022
Objection resolved — Addressed
01/19/2022
Objection raised — Structural
01/19/2022
Objection resolved — Addressed
01/19/2022
Objection raised — Fire_Protection
01/19/2022
Objection resolved — Addressed
01/19/2022
Objection raised — Fire_Protection
01/19/2022
Objection resolved — Addressed
01/19/2022
Objection raised — Fire_Protection
01/19/2022
Objection resolved — Addressed
01/19/2022
Objection raised — Scope
01/19/2022
Objection resolved — Addressed
01/19/2022
Objection raised — Admin
01/19/2022
Objection resolved — Addressed
01/19/2022
Objection raised — Admin
01/19/2022
Objection resolved — Addressed
12/01/2021
Objection raised — Admin
12/01/2021
Objection resolved — Addressed
07/27/2021
Objection raised — Structural
07/27/2021
Objection resolved — Addressed
07/27/2021
Objection raised — Inspections
07/27/2021
Objection resolved — Addressed
07/13/2021
Filed — Alteration
X00541840-I1
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARQUITECTURA VARELA305/17/2023
GREEN DESIGN107/13/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ALLCITYEXPEDITING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Z TECH BUILDING SOLUTIONSGeneral Contractor407/08/2026
DPH PLUMBING & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BUTTERFIELD & O'CONNOR4189405/17/2023
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offZ TECH BUILDING SOLUTIONS03/24/2023
DOB NOWPlumbingSigned-offDPH PLUMBING & HTG CORP11/17/2022
DOB NOWGeneral ConstructionPermit IssuedZ TECH BUILDING SOLUTIONS10/24/2022
BISOTISSUEDZALIDAR BROS PT & CON COR12/26/2008
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
05/22/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
05/12/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
05/09/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/23/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/23/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/19/2023Fire-Resistant Penetrations and JointsBRIAN T. O'CONNORspecial
05/17/2023Fire-Resistant Penetrations and JointsBRIAN T. O'CONNORspecial
03/07/2023Fire-Resistant Penetrations and JointsBRIAN T. O'CONNORspecial
03/07/2023Fire-Resistance Rated ConstructionVicente Varelaprogress
03/07/2023FinalVicente Varelaprogress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/23/2026X00839852-I1Request digital key ↗
08/23/2026X08007368-P1Request digital key ↗
08/23/2026X08007368-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
11/18/2008210079332Open ↗
▸BISWORK PERMIT APPLICATION1
12/26/2008210079332Open ↗
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/25/2026X00541840-I1Open ↗
08/23/2026X00839852-I1Open ↗
08/13/2026X08007368-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026X08007368-I1Open ↗
08/26/2026X08007368-P1Open ↗
08/23/2026X00839852-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026X00839852-I1Open ↗
08/23/2026X00839852-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
11/18/2008210079332Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
11/18/2008210079332Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
11/18/2008210079332Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/23/2026X00839852-I1Open ↗
08/15/2026X00541840-I1Open ↗
08/13/2026X08007368-P1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
12/02/2008210079332Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
11/19/2008210079332Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
11/18/2008210079332Open ↗