ECB08/05/2026BC3314.1 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED AT EXP# 3 BALCONY AND INTERIOR PLANKS LOOSE NOT TIED DOWN. SCAFFOLD NOT ANCHORED TO STRUCTURE MISSING CROSS-BRASS AND MUDSILL NO GUARDRAIL SY$5K due
ECB08/05/2026BC 3301.2 INADEQUATE SAFETY MEASURES AT TIME OF INSPECTION OBSERVED WORKER ON UNSAFE SUPPORTED SCAFFOLD AT BALCONIES AND AT INTERIOR WORKER NOT TIES OFF AND NO FALL PROTECTION NO GUARDRAILS. STOP ALL EXTERIOR W$5K due
ECB08/05/2026DURING MY INSPECTION AND UPON REVIEWING DOB NOW AND BIS SYSTEM REVEAL SSM / SSC/ CS MICHAEL SPINELLA USING HIS LICENSE ON DESIGNATED PERMITS B01086106, B00805221 AND INCLUDING B00996246 NOT IN COMPLIANCE WITH C$2K due
ECB02/25/2026GC-625238 AT 5:15AM OBSERVED 5 STORY BUILDING WITH SWS THAT WAS NOT ILLUMINATED AS STIPULATED IN BC3307.6.4.8 CREATES HAZARDOUS CONDITIONS FOR PEDESTRIANS OF SLIPS AND TRIPS DUE TO INADEQUATE LIGHTING IN DARK C$10K due
ECB03/28/2025JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. CORRUGATED GALVANIZED CONSTRUCTION FENCE APPROX. 15 LINEAR FT AND SUPPORTING METAL POST LOOSE AND LEANING OUTWARD., COMPLY WITH CODE$5K due
ECB11/20/2025OBSERVED ACTIVE JOBSITE W/ CONSTRUCTION FENCE ERECTED AT EXPOSURE #1 MISSING 1-1/2 m SCH. 40 PIPE KICKER CLAMPED TO 3m SCH. 40 PIPE CONTRARY TO THE APPRO VED PLANS. CONDITION COULD LEAD TO DISPLACEMENT OF FNothing owed — awaiting certificate of correction
ECB11/20/2025OBSERVD JOBSITE W/DEBRIS CHUTE INSTALLED @ EXPO#3 BALCONIES MISSING TIEBACKS AND ANGLED W/ ADDITIONAL SUPPRTS @1ST FLR CONTRARY TO APPROVED DWGS. CHUTE ACCESS BEYOND PROTECTION. REQUEST FOR WORKERS PROTECTION MNothing owed — awaiting certificate of correction
ECB11/20/2025OBSERVED ACTIVE JOBSITE W/ UNFINISHED FACADE, UNFINISHED ROOF, INCOMPLETE PARAPETS ALL LESS THAN 20FT AWAY FROM UNPROTECTED ADJOINING PROPERTY WINDOWS AT EXPOSURE #2. VISIBLE CONCRETE SPLASH MARKS ON SEVERAL WINothing owed — awaiting certificate of correction
ECB12/22/2021JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. OBSERVED A 10 FT HIGH METAL FENCE IS LOOSE/ OPEN AT REAR, VIEWING PANEL OPEN AND FENCE GATE LEANING AT FRONT OF LOT., COMPLY WITH CODENothing owed — awaiting certificate of correction
ECB11/28/2007JOB SITE FENCE DEFECTIVE PERMIT 302090911-01-EQ-FN A WOOD TYPE CONSTRUCTION FENCE NOTED DEFECTS AT FRONT TWO MAIN ENTRY DOORS ARE IN DANGER OF FALLING HANGING ON A 2"X4" WOOD POST. 3 PANELS NEED TO BE REPLACEDNothing owed — awaiting certificate of correction
ECB02/06/200727-194.FAILURE TO POST PERMITS.JOB SITE HAS NO PERMITS POSTED DEBRIS,SLABS IN PLACE.NO WORK @ TIME OF INSPECTION.REMEDY:POST ALL WORK PERMITNothing owed — awaiting certificate of correction
ECB02/06/2003FENCE EXCEEDS PERMITS HEIGHTS ZONING MAP 28D INDICATES R5 ZONE RESIDENCE FENCE EXCEDD PERMITTED HEIGHT OF 6TH FENCE IS 6FT 8 INCHES APROUND ENTRIRE PREIMTER REMEDY : CONFORM TO FENCE CODENothing owed — awaiting certificate of correction