← Back
Predominantly retail with other uses
296 EAST 149 STREET
BRONX · BIN 2000892
💬 Discuss this project
1931Year Built
4Stories
K4Building Class
C4-4Zoning
1,500 sfGross Floor Area
1Units
Rent Stabilized12 Open Violations 11 unresolved · 1 paperwork only ▸
Predominantly retail with other uses · Owner of record: 296-298 E. 149 STREET LLC · 2,163 sf lot · 0.69 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingGeneral
Permit Issued — active, not yet Signed-off
Roof7p · 3 filings · 17 docs
Floor 4Under Construction6p · 2 filings · 5 docs
Floor 3Under Construction5p · 2 filings · 5 docs
Floor 2Under Construction5p · 2 filings · 5 docs
Floor 1Under Construction4p · 2 filings · 5 docs
Cellar1p · 1 filing · 5 docs
Sub-Cellar5p · 2 filings · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
IRGANG GROUP303/22/2026
296 EAST 149 ST LLC103/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
COMMERCIAL CAPITAL USA403/21/2026
MP DESIGN AND CONSTRUCTION1003/21/2026
BSGNY203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TOTAL BUILDER CONSTRUCTIOGeneral Contractor409/02/2026
GLENNS PLUMBING SVCS INCPlumbing209/03/2026
AI FANG WUElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ROBERT ARTHUR KING, R.A.4042107/25/2023
Building Lifecycle
All (47)Filed (9)Permit Issued (6)Signed Off (3)Violation (25)Inspection (2)Special Inspection (2)
09/02/2026
Permit issued — Plumbing
X01289385-S1-PL
09/01/2026
Permit issued — General Construction
X01289385-I1-GC
10/29/2025
Filed — Alteration CO
PLUMBING SCOPE OF WORK RELATED TO THE CHANGE OF USE OF 2ND TO 4TH FLOORS FROM OFFICE TO RESIDENTIAL. INSTALL (9) NEW SHOWERS, (3) NEW KITCHEN SINKS, (3) NEW DISHWASHERS, (3) NEW WASHERS.
X01289385-I1
02/19/2025
Permit issued — General Construction
X01176491-I1-GC
02/05/2025
Filed — Alteration
FILING FOR EXISTING CONDITIONS IN BUILDING, RENOVATE EXISTING SPACE TO BE A PHARMACY, REPLACEMENT OF HVAC UNITS IN ROOF. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
X01176491-S1
02/05/2025
Filed — Alteration
FILING FOR EXISTING CONDITIONS IN BUILDING, RENOVATE EXISTING SPACE TO BE A PHARMACY, REPLACEMENT OF HVAC UNITS IN ROOF. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
X01176491-I1
11/27/2024
Signed off — Alteration
RENOVATION OF EXISTING OFFICE SPACE. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
X01074802-S1
11/15/2024
Signed off — Alteration
RENOVATION OF EXISTING OFFICE SPACE. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
X01074802-I1
11/08/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/12/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/03/2024
Permit issued — General Construction
X01074802-I1-GC
07/03/2024
Permit issued — Plumbing
X01074802-S1-PL
07/01/2024
Filed — Alteration
RENOVATION OF EXISTING OFFICE SPACE. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
X01074802-S1
07/01/2024
Filed — Alteration
RENOVATION OF EXISTING OFFICE SPACE. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
X01074802-I1
05/28/2024
Signed off — Alteration
Filing to repair structural damages to roof due to fire. Replacement of wood joists and roofing membrane.
X00891199-I1
05/09/2024
Permit issued — Structural
X00891199-I1-ST
07/25/2023
Filed — Alteration
Filing to repair structural damages to roof due to fire. Replacement of wood joists and roofing membrane.
X00891199-I1
06/15/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
ROBERT ARTHUR KING, FAIA
06/15/2023
Special inspection requirement — Final
tarek zeid
09/29/2022
Filed — Alteration CO
X00777608-I1
12/08/2020
Filed — Alteration
X00438219-I1
04/14/2020
Filed — Alteration
HERBERY FILING AN 8'-0" HIGH CONSTRUCTION FENCE IN CONJUNCTION WITH DEMOLITION APPLICATION OF A 4 STORY STRUCTURE ON SITE.
X00153931-I1
08/03/2019
Violation issued (ECB, closed)
Construction
06/01/2019
Violation issued (ECB, closed)
Construction
04/05/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/05/2019
Violation issued (ECB, closed)
Construction
10/11/2018
Violation issued (HPD, closed)
I
11/28/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/13/2017
Violation issued (HPD, closed)
I
10/28/2016
Violation issued (HPD, closed)
I
10/14/2016
Violation issued (HPD, open)
B
10/02/2015
Violation issued (HPD, closed)
I
02/04/2015
Violation issued (HPD, closed)
I
03/06/2013
Violation issued (HPD, open)
B
10/15/2011
Violation issued (HPD, open)
B
10/22/2010
Violation issued (ECB, open)
Plumbing
12/23/1998
Violation issued (HPD, open)
B
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/06/1996
Violation issued (HPD, closed)
A
05/17/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/12/1984
Violation issued (HPD, open)
C
03/12/1984
Violation issued (HPD, open)
B
03/12/1984
Violation issued (HPD, open)
C
05/12/1983
Violation issued (HPD, open)
C
05/12/1983
Violation issued (HPD, open)
C
05/12/1983
Violation issued (HPD, open)
C
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedGLENNS PLUMBING SVCS INC09/02/2026
DOB NOWGeneral ConstructionPermit IssuedTOTAL BUILDER CONSTRUCTIO09/01/2026
DOB NOWGeneral ConstructionPermit IssuedTOTAL BUILDER CONSTRUCTIO02/19/2025
DOB NOWGeneral ConstructionSigned-offTOTAL BUILDER CONSTRUCTIO07/03/2024
DOB NOWPlumbingSigned-offGLENNS PLUMBING SVCS INC07/03/2024
DOB NOWStructuralSigned-offTOTAL BUILDER CONSTRUCTIO05/09/2024
BISOTISSUEDCORAL CROWN CONSTRUCTION CORP.09/17/1997
BISPLISSUEDMAGOR PLUMBING & HEATING06/23/1997
BISMHISSUEDMEI LIN CONSTRUCTION INC.06/19/1997
2 projects · most recent 10/29/2025
Water/Sanitary
FiledStatusContractorScope
10/29/2025Permit IssuedGLENNS PLUMBING SVCS INCWater/Sanitary
02/05/2025——Water/Sanitary
2 projects · most recent 11/15/2021
General Wiring
FiledStatusContractorScope
11/15/2021Permit IssuedKWONG MING ELECTRIC INCGeneral Wiring
11/10/2021Permit IssuedKWONG MING ELECTRIC INC8 meters, 8 new_meters
1 project · most recent 04/14/2020
Fence
FiledStatusContractorScope
04/14/2020——Fence
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
11/08/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/12/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
06/15/2023Structural Stability – Alterations of existing buildingsROBERT ARTHUR KING, FAIAspecial
06/15/2023Finaltarek zeidprogress
▾Documents — 38 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch5
08/22/2026X00891199-I1Request digital key ↗
08/21/2026X01074802-S1Request digital key ↗
08/21/2026X01074802-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Construction Fence1
08/15/2026X00153931-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sidewalk Shed1
08/25/2026X00438219-I1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
04/18/2019220699769Open ↗
06/17/2009220012304Open ↗
▸BISWORK PERMIT APPLICATION1
06/17/2009220012304Open ↗
▸Seals & Professional Certifications13
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/26/2026X00153931-I1Open ↗
08/25/2026X00438219-I1Open ↗
08/22/2026X00891199-I1Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
04/22/2019220012304Open ↗
06/17/2009220012304Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
06/17/2009220012304Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
06/17/2009220012304Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/24/2026X00891199-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026X00891199-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
06/17/2009220012304Open ↗
▸Safety & Tenant Protection4
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
04/18/2019220699769Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X00777608-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026X00777608-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026X00777608-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/22/2026X00891199-I1Open ↗
08/13/2026X01176491-I1Open ↗
08/13/2026X01074802-S1Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
06/17/2009220012304Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
06/17/2009220012304Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
06/17/2009220012304Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
04/18/2019220699769Open ↗
06/17/2009220012304Open ↗
▸Other Documents1
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
08/13/2026X00891199-I1Open ↗