HPD09/17/2026§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT VESTIBULE DOOR
HPD08/26/2026§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT COMPACTOR CLOSET, 3rd STORY
HPD11/12/2023§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 3 SQ FT AT NORTH WALL IN THE BATHROOM LOCATED AT APT F3, 6th STORY, 4th APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 16374341 ISSUED 12-NOV-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
HPD11/12/2023§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT F3, 6th STORY, 4th APARTMENT FROM WEST AT NORTH
DOB12/01/2021FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB04/29/2021FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
HPD02/11/2021§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM WEST AT NORTH WALL, 1st WINDOW FRAME FROM NORTH AT EAST WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 1B, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD02/11/2021§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE FOYER LOCATED AT APT 1B, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST
DOB10/21/2020V-DOB VIOLATION - ACTIVE
DOB08/26/2019V-DOB VIOLATION - ACTIVE
DOB05/26/2015ECB-VIO#35095186J DT.5/19/15.THE FACADE INSPECTION REPORT 7 NOTES THE CONDITION SAFE,THE FACADE WAS OBSERVED TOBE DEFECTIVE & REQUIRES IMMEDIATE REPAIR. IMMEDIATELY BY C.O.B.06/12/15 PROVIDE NYC DOB FISP UNIT WITH A FACADE INSPECTION REPORT PREPARED BY QEWI-NOTE ALL FACADE CONDITIONS COMPARED TO CYCLE 7 REPORT
ECB12/05/2022FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:AT TIME OF INSPECTION OBSERVED ON EXP #1 EAST ELEVATIONS MISSING DAMAGED MORTAR JOINTS AT PARAPET & 5TH FLOOR SPANDREL ALSO AT 3RD FL LINTEL RIGHT OFNothing owed — awaiting certificate of correction
ECB08/18/2021TUBES LKING IN FRNT OF BLR,BOLT MISSING ON BLR DR,CLN COMB.AIR FAN,OIL TO GAS NOT SIGNED OFF,SEAL BASE,CORRECT VIOLATIONS &SEND CERTIFICATE OF CORRECTIONNothing owed — awaiting certificate of correction