HPD11/25/2016SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE BATHROOM LOCATED AT APT 12C, 12th STORY, 2nd APARTMENT FROM NORTH AT EAST
HPD11/25/2016SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 12C, 12th STORY, 2nd APARTMENT FROM NORTH AT EAST
ECB04/11/2024Failure to submit an acceptable required cycle 9B report critical of examination documenting condition of exterior wall abd appurtenances required by 28-302.4 for control #910212. Remedy: submit acceptable requNothing owed — awaiting certificate of correction
ECB04/11/2024Failure to submit an acceptable required cycle 9B report critical of examination documenting condition of exterior wall abd appurtenances required by 28-302.4 for control #910211. Remedy: submit acceptable requNothing owed — awaiting certificate of correction
ECB04/11/2024Failure to submit an acceptable required cycle 9B report critical of examination documenting condition of exterior wall abd appurtenances required by 28-302.4 for control #910210. Remedy: submit acceptable requNothing owed — awaiting certificate of correction
ECB11/09/2022Failure to comply with NYC fire code - observed,welding operations at 2ND fl. Hot work permit was not available or provided upon request. Also, no FDNY permit provided for towable diesel generator in operationNothing owed — awaiting certificate of correction
ECB11/09/2022Dropping or throwing prohibited - observed,worker dropping/ throwing material/ debris from elevated 2ND floor to dumpster which was placed at ground level (20 feet distance), above the designated egress/ buildiNothing owed — awaiting certificate of correction
ECB11/09/2022Fire extinguishers - observed, fire extinguishers missing inspection tags, monthly inspection not conducted as per 906.2.1.1 (last inspection was conducted 09.01.22), pressure gauge is not in operable position,Nothing owed — awaiting certificate of correction
ECB04/21/2022Jobsite fence not constructed or maintained pursuant to subsection.at the time of inspection at a 3 story new building at foundation stage active jobsite,observed construction fence#B00397208-I1-fn not maintainNothing owed — awaiting certificate of correction
ECB12/22/2021Failure to institute/maintain safety equipment measures or temporary construction-no guard rails. At time of inspection observed open excavation area with an approximate 8' drop no fall protection/guard rails iNothing owed — awaiting certificate of correction
ECB07/12/2021Project info panel/const sign not provided or not in compliance w/sec noted:atoi i observed proposed 7STYNB w/no work present.it was also observed contractor failed to post/display project info panel of const fNothing owed — awaiting certificate of correction
ECB07/12/2021Failure to maintain onsite/display onsite doc required by BCCH33 (no DOT permit) note:atoi i observed proposed 2STYNB w/no work activity present.it was also observed contractor failed to post DOT permits for doNothing owed — awaiting certificate of correction
ECB07/12/2021Failure to post or properly post permit for work@premises.note:atoi i observed proposed 2STYNB currently@grade level w/no work activity present.it was also observed contractor failed to post any permits defailiNothing owed — awaiting certificate of correction
ECB09/02/2012Sidewalk shed does not conform to code specification: approx 16 ( )ft of shed in state of disrepair knocked off wood supports & leaning. Remedy: conform to code specifications.Nothing owed — awaiting certificate of correction