Five to six families
298 STOCKHOLM STREET
BROOKLYN · Bushwick (West) · BIN 3074229
💬 Discuss this project
1931Year Built
3Stories
C2Building Class
R6Zoning
4,875 sfGross Floor Area
6Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Five to six families · Owner of record: STOCKHOLM EQUITIES NY LLC · 2,500 sf lot · 1.95 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Roof30p · 2 filings · 20 docs
Floor 344p · 2 filings · 20 docs
Floor 242p · 2 filings · 20 docs
Floor 143p · 2 filings · 20 docs
Cellar44p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
65TH PLACE HOLDINGS2204/09/2026
STOCKHOLM EQUITIES303/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/13/2024$620K—PMK MANAGEMENT LLC → STOCKHOLM EQUITIES NY LLC$127/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LESTER KATZ, NCARB208/01/2024
CHOSEN MEP, CORP.407/23/2024
FC CONSULTING ENGINEER, PLLC105/08/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CHS CONTRACTING LLCGeneral Contractor504/09/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
KISHAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616608/01/2024
Building Lifecycle
All (165)Filed (7)Permit Issued (5)Signed Off (4)Violation (60)Inspection (11)Objection (48)Special Inspection (30)
05/06/2026
Violation issued (HPD, closed)
A
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/09/2025
Violation issued (HPD, closed)
B
01/14/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/31/2024
Violation issued (HPD, closed)
C
12/18/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
12/05/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
09/11/2024
Signed off — Alteration CO
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00989009-I1.
B00989009-S2
09/11/2024
Signed off — Alteration CO
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00989009-I1.
B00989009-S3
09/06/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/03/2024
Signed off — Alteration
INTERIOR DEMOLITION OF EXISTING 3 STORY BUILDING IN CONJUNCTION WITH GC/ALT 1 APPLICATION #B00989009-I1.
B01048095-I1
08/27/2024
Signed off — Alteration CO
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00989009-I1.
B00989009-S1
08/26/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/23/2024
Permit issued — Mechanical Systems
B00989009-S1-MS
08/23/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
08/21/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/13/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
08/13/2024
Special inspection requirement — Interior lighting power
FAHAD FATEH
08/13/2024
Special inspection requirement — Air barrier - visual inspection
FAHAD FATEH
08/13/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
08/13/2024
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
08/13/2024
Special inspection requirement — Metering
FAHAD FATEH
08/13/2024
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
08/13/2024
Special inspection requirement — Fenestration areas
FAHAD FATEH
08/13/2024
Special inspection requirement — Permanent certificate
FAHAD FATEH
08/13/2024
Special inspection requirement — Maintenance information
FAHAD FATEH
08/13/2024
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
08/13/2024
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
08/13/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
08/12/2024
Objection resolved — Addressed
08/09/2024
Objection raised — Other
08/01/2024
Filed — Alteration CO
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00989009-I1.
B00989009-P2
07/31/2024
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
FAHAD FATEH
07/31/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
07/31/2024
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
07/31/2024
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
07/31/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
07/31/2024
Special inspection requirement — Maintenance information
FAHAD FATEH
07/30/2024
Special inspection requirement — Metering
FAHAD FATEH
07/30/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
07/30/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
07/30/2024
Special inspection requirement — Maintenance information
FAHAD FATEH
07/30/2024
Special inspection requirement — Fenestration areas
FAHAD FATEH
07/30/2024
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
07/30/2024
Special inspection requirement — Permanent certificate
FAHAD FATEH
07/30/2024
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
07/30/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
07/30/2024
Special inspection requirement — Air barrier - visual inspection
FAHAD FATEH
07/30/2024
Special inspection requirement — Interior lighting power
FAHAD FATEH
07/23/2024
Filed — Alteration CO
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION #B00989009-I1.
B00989009-P1
07/18/2024
Permit issued — Sprinklers
B00989009-S3-EW-SP
07/12/2024
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
07/12/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/01/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/01/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/21/2024
Permit issued — General Construction
B00989009-I1-GC
06/17/2024
Permit issued — Plumbing
B00989009-S2-PL
05/22/2024
Permit issued — General Construction
B01048095-I1-GC
05/21/2024
Objection resolved — Addressed
05/08/2024
Filed — Alteration
INTERIOR DEMOLITION OF EXISTING 3 STORY BUILDING IN CONJUNCTION WITH GC/ALT 1 APPLICATION #B00989009-I1.
B01048095-I1
Latest 60 of 165 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offCHS CONTRACTING08/23/2024
DOB NOWSprinklersSigned-offA M B MECHANICAL INC07/18/2024
DOB NOWGeneral ConstructionPermit IssuedCHS CONTRACTING06/21/2024
DOB NOWPlumbingSigned-offN AND S PLUMBING INC06/17/2024
DOB NOWGeneral ConstructionSigned-offCHS CONTRACTING05/22/2024
1 project · most recent 08/01/2024
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/01/2024Signed-offCHS CONTRACTING LLCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric 4MXS36WMVJU9 36,000 BTU · Condensing Unit ×4
2MXS18NMVJUA 18,900 BTU · Condensing Unit ×3
3MXS24RMVJUA9 24,000 BTU · Condensing Unit ×1
1 project · most recent 08/01/2024
Sprinkler System
FiledStatusContractorScope
08/01/2024Signed-offPRIME PIPING & HEATING INSprinkler System
1 project · most recent 08/01/2024
Storm Water/Sanitary
FiledStatusContractorScope
08/01/2024Signed-offKISHAN PLUMBING INCStorm, Water/Sanitary
3 projects · most recent 01/31/2025
General Wiring
FiledStatusContractorScope
01/31/2025CompleteHIVOLTS ELECTRICAL INCGeneral Wiring
12/02/2024CompleteACCURATE ELEC'L CORP.General Wiring
06/09/2024CompleteACCURATE ELEC'L CORP.General Wiring
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
01/14/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/18/2024Fail-Final CND-Occupancy InspectionFailView ↗
12/05/2024Fail-Final CND-Occupancy InspectionFailView ↗
09/06/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/26/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/23/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/21/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/12/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
07/12/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/01/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/01/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 38
DateRequirementInspectorRole
08/13/2024Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
08/13/2024Interior lighting powerFAHAD FATEHenergy_progress
08/13/2024Air barrier - visual inspectionFAHAD FATEHenergy_progress
08/13/2024Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
08/13/2024Fenestration air leakageFAHAD FATEHenergy_progress
08/13/2024MeteringFAHAD FATEHenergy_progress
08/13/2024Insulation placement and R valuesFAHAD FATEHenergy_progress
08/13/2024Fenestration areasFAHAD FATEHenergy_progress
08/13/2024Permanent certificateFAHAD FATEHenergy_progress
08/13/2024Maintenance informationFAHAD FATEHenergy_progress
08/13/2024Fire-Resistance Rated ConstructionFAHAD FATEHprogress
08/13/2024Energy Code Compliance InspectionsFAHAD FATEHprogress
08/13/2024Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
07/31/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationFAHAD FATEHspecial
07/31/2024Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
07/31/2024HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
07/31/2024HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
07/31/2024HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
07/31/2024Maintenance informationFAHAD FATEHenergy_progress
07/30/2024MeteringFAHAD FATEHenergy_progress
07/30/2024Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
07/30/2024Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
07/30/2024Maintenance informationFAHAD FATEHenergy_progress
07/30/2024Fenestration areasFAHAD FATEHenergy_progress
07/30/2024Fenestration air leakageFAHAD FATEHenergy_progress
Latest 25 of 38.
▾Documents — 36 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/25/2026B01048095-I1Request digital key ↗
08/24/2026B00989009-S3Request digital key ↗
08/24/2026B00989009-P2Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00989009-I1Open ↗
▸Seals & Professional Certifications17
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/13/2026B00989009-S1Open ↗
08/13/2026B00989009-S3Open ↗
08/13/2026B00989009-S2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026B00989009-P2Open ↗
09/01/2026B00989009-P2Open ↗
08/28/2026B00989009-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026B00989009-P2Open ↗
08/28/2026B00989009-I1Open ↗
08/25/2026B00989009-P1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/13/2026B00989009-I1Open ↗
08/13/2026B00989009-P2Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/13/2026B00989009-S2Open ↗
08/13/2026B00989009-I1Open ↗
08/13/2026B00989009-S3Open ↗
Showing 3 of 7 on file for this type
▸Other Documents2
▸DOB NOWProperty Ownership Certification2
08/13/2026B00989009-I1Open ↗
08/13/2026B00989009-P2Open ↗