← Back
Three families
299 7 STREET
BROOKLYN · BIN 3021619
💬 Discuss this project
1901Year Built
3Stories
C0Building Class
R6BZoning
2,346 sfGross Floor Area
3Units
Rent Stabilized8 Open Violations ▸FDNY Report ↗
Three families · 1,700 sf lot · 1.38 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalFire ProtectionGeneralOther
Roof1p · 1 filing · 6 docs
Floor 23p · 2 filings · 17 docs
Floor 14p · 2 filings · 17 docs
Cellar5p · 2 filings · 17 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
211 PROSPECT AVE603/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FORMACTIV311/14/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PANTOCRAFT603/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FORMACTIV ARCHITECTURE3024311/14/2025
Building Lifecycle
All (87)Filed (3)Violation (15)Objection (39)Special Inspection (30)
04/30/2026
Violation issued (HPD, open)
A
04/01/2026
Objection resolved — Addressed
02/25/2026
Objection resolved — Addressed
02/08/2026
Objection resolved — Addressed
01/16/2026
Objection resolved — Addressed
01/15/2026
Objection resolved — Addressed
12/17/2025
Objection resolved — Addressed
12/17/2025
Objection resolved — Addressed
12/17/2025
Objection resolved — Addressed
12/17/2025
Objection resolved — Addressed
12/17/2025
Objection resolved — Addressed
12/17/2025
Objection resolved — Addressed
12/17/2025
Objection resolved — Addressed
12/04/2025
Objection raised — Other
12/04/2025
Objection raised — Other
12/01/2025
Objection raised — Other
12/01/2025
Objection raised — Accessibility
12/01/2025
Objection raised — Scope
12/01/2025
Objection raised — Zoning
12/01/2025
Objection raised — Accessibility
12/01/2025
Objection raised — Zoning
12/01/2025
Objection raised — Other
12/01/2025
Objection raised — Scope
12/01/2025
Objection raised — Fire_Protection
12/01/2025
Objection raised — Fire_Protection
11/14/2025
Filed — Alteration
Subsequent plumbing work at 1st floor apartment as per. plans filed herewith. No change to use, egress, or occupancy under this application.
B01316815-I1
11/14/2025
Filed — Alteration
Subsequent plumbing work at 1st floor apartment as per. plans filed herewith. No change to use, egress, or occupancy under this application.
B01316815-S1
11/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ron Eng
11/13/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Ron Eng
11/13/2025
Special inspection requirement — Energy Code Compliance Inspections
Ron Eng
11/13/2025
Special inspection requirement — Tenant Protection Plan Compliance
Ron Eng
11/10/2025
Special inspection requirement — Tenant Protection Plan Compliance
11/10/2025
Special inspection requirement — Mechanical Systems
11/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ron Eng
11/10/2025
Special inspection requirement — Final
11/10/2025
Special inspection requirement — Energy Code Compliance Inspections
11/10/2025
Special inspection requirement — Fire-Resistance Rated Construction
11/10/2025
Special inspection requirement — Air barrier - visual inspection
11/10/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
11/10/2025
Special inspection requirement — Fenestration areas
11/10/2025
Special inspection requirement — Fenestration air leakage
11/10/2025
Special inspection requirement — Lighting controls
11/10/2025
Special inspection requirement — Insulation placement and R values
11/10/2025
Special inspection requirement — Lighting in dwelling units
06/25/2025
Objection resolved — Addressed
06/05/2025
Violation issued (HPD, open)
A
06/02/2025
Objection resolved — Addressed
01/15/2025
Objection raised — Cost
01/15/2025
Objection raised — Other
01/15/2025
Objection raised — Accessibility
01/08/2025
Objection resolved — Resolved
01/08/2025
Objection resolved — Addressed
01/08/2025
Objection resolved — Resolved
11/22/2024
Objection raised — Other
11/22/2024
Objection raised — Other
11/22/2024
Objection raised — Admin
11/22/2024
Objection raised — Scope
11/22/2024
Objection raised — Other
11/22/2024
Objection raised — Zoning
11/22/2024
Objection raised — Zoning
Latest 60 of 87 events.
Nothing on file for this building.
1 project · most recent 11/14/2025
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
11/14/2025——Air Conditioning Systems
1 project · most recent 11/14/2025
Gas Water/Sanitary
FiledStatusContractorScope
11/14/2025——Gas, Water/Sanitary
▾Special Inspection Requirements (DOB NOW) — 30
DateRequirementInspectorRole
11/13/2025Fire-Resistant Penetrations and JointsRon Engspecial
11/13/2025HVAC-R and service water piping design and insulationRon Engenergy_progress
11/13/2025Energy Code Compliance InspectionsRon Engprogress
11/13/2025Tenant Protection Plan ComplianceRon Engspecial
11/10/2025Tenant Protection Plan Compliance—special
11/10/2025Mechanical Systems—special
11/10/2025Fire-Resistant Penetrations and JointsRon Engspecial
11/10/2025Final—progress
11/10/2025Energy Code Compliance Inspections—progress
11/10/2025Fire-Resistance Rated Construction—progress
11/10/2025Air barrier - visual inspection—energy_progress
11/10/2025Fenestration and door U-factor and product ratings—energy_progress
11/10/2025Fenestration areas—energy_progress
11/10/2025Fenestration air leakage—energy_progress
11/10/2025Lighting controls—energy_progress
11/10/2025Insulation placement and R values—energy_progress
11/10/2025Lighting in dwelling units—energy_progress
10/01/2024Air barrier - visual inspectionRon Engenergy_progress
10/01/2024Fenestration and door U-factor and product ratingsRon Engenergy_progress
10/01/2024Fenestration air leakageRon Engenergy_progress
10/01/2024Insulation placement and R valuesRon Engenergy_progress
10/01/2024Lighting controlsRon Engenergy_progress
10/01/2024Fenestration areasRon Engenergy_progress
10/01/2024Lighting in dwelling unitsRon Engenergy_progress
06/26/2024Tenant Protection Plan ComplianceRon Engspecial
Latest 25 of 30.
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/15/2026B01316815-S1Request digital key ↗
08/15/2026B01316815-I1Request digital key ↗
08/14/2026B01072643-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZoning Exhibit form (1-5)1
08/15/2026B01316815-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B01072643-I1Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/19/2026B01316815-S1Open ↗
08/19/2026B01316815-I1Open ↗
08/13/2026B01072643-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/29/2026B01316815-S1Open ↗
09/29/2026B01316815-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/29/2026B01316815-S1Open ↗
09/29/2026B01316815-S1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/15/2026B01316815-S1Open ↗
08/15/2026B01316815-I1Open ↗
08/13/2026B01072643-I1Open ↗
▸Other Documents2
▸DOB NOWPlot Diagram1
08/13/2026B01072643-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B01072643-I1Open ↗