← Back
Factory, industrial, miscellaneous
3-33 GRANDVIEW AVENUE
QUEENS · Ridgewood · BIN 4080200
💬 Discuss this project
1931Year Built
2Stories
F9Building Class
R5BZoning
2,400 sfGross Floor Area
1Units
13 Open Violations 11 unresolved · 2 paperwork only ▸FDNY Report ↗
Factory, industrial, miscellaneous · 1,696 sf lot · 1.42 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Permit Issued — active, not yet Signed-off
Floor 3Under Construction10p · 2 filings · 20 docs
Floor 2Under Construction12p · 2 filings · 20 docs
Floor 1Under Construction10p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
H BUILDING MANAGEMENT203/22/2026
APASHI LLC103/22/2026
BAPSHI203/21/2026
BENI CONSTRUCTION203/21/2026
BAPASHI203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
A&A CONSULTING ENGINEERS PC402/11/2026
BUILDING ENGINEERING SYSTEMS PLLC102/05/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
H BUILDING MANAGEMENT INCGeneral Contractor409/26/2026
OLIVER CHRISTOPHERElectrical103/21/2026
RISER PLBG & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A&A CONSULTING ENG. PC3252302/11/2026
ALMA ENGINEERING, P.C.7833202/11/2026
Building Lifecycle
All (51)Filed (5)Permit Issued (5)Violation (15)Special Inspection (26)
09/25/2026
Permit issued — General Construction
Q00860766-I1-GC
07/06/2026
Violation issued (ECB, open)
Unknown
02/11/2026
Filed — Alteration CO
Q00860766-P1
02/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SAEED AINECHI
02/10/2026
Special inspection requirement — Lighting in dwelling units
SAEED AINECHI
02/10/2026
Special inspection requirement — Fenestration air leakage
SAEED AINECHI
02/10/2026
Special inspection requirement — Fenestration areas
SAEED AINECHI
02/10/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
SAEED AINECHI
02/10/2026
Special inspection requirement — Air barrier - visual inspection
SAEED AINECHI
02/10/2026
Special inspection requirement — Fire-Resistance Rated Construction
SAEED AINECHI
02/10/2026
Special inspection requirement — Final
SAEED AINECHI
02/10/2026
Special inspection requirement — Energy Code Compliance Inspections
SAEED AINECHI
02/10/2026
Special inspection requirement — Tenant Protection Plan Compliance
02/10/2026
Special inspection requirement — Structural Steel - Details
SAEED AINECHI
02/10/2026
Special inspection requirement — Structural Cold-Formed Steel
SAHAND AINECHI
02/10/2026
Special inspection requirement — Concrete - Cast-In-Place
SAEED AINECHI
02/09/2026
Violation issued (ECB, closed)
Construction
12/02/2025
Permit issued — Plumbing
Q00954421-I1-PL
11/17/2025
Violation issued (ECB, closed)
Construction
11/14/2025
Permit issued — Structural
Q00860766-I1-ST
11/12/2025
Permit issued — Structural
Q00860766-I1-GC
11/10/2025
Permit issued — Construction Fence
Q01310460-I1-FN
10/29/2025
Filed — Alteration
Q01310460-I1
03/25/2025
Filed — Alteration
PROPOSED ONE FAMILY DWELLING, VERTICAL EXTENSION FROM 2 TO PARTIAL 3 STORY RESIDENTIAL BUILDING. PROPOSED PLUMBING FIXTURES AS NOTED ON PLANS. GENERAL CONSTRUCTION WORK TO BE FILED UNDER SEPARATE APPLICATION.
Q00954421-I1
03/25/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SAEED AINECHI
10/27/2023
Special inspection requirement — Concrete - Cast-In-Place
SAEED AINECHI
08/01/2023
Filed — Alteration CO
Q00860766-I1
07/18/2023
Special inspection requirement — Lighting in dwelling units
SAEED AINECHI
07/18/2023
Special inspection requirement — Fenestration air leakage
SAEED AINECHI
07/18/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
SAEED AINECHI
07/18/2023
Special inspection requirement — Air barrier - visual inspection
SAEED AINECHI
07/18/2023
Special inspection requirement — Energy Code Compliance Inspections
SAEED AINECHI
07/18/2023
Special inspection requirement — Fire-Resistance Rated Construction
SAEED AINECHI
07/18/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
SAEED AINECHI
07/18/2023
Special inspection requirement — Fenestration areas
SAEED AINECHI
04/18/2023
Special inspection requirement — Structural Steel - Details
SAEED AINECHI
04/18/2023
Special inspection requirement — Structural Cold-Formed Steel
SAHAND AINECHI
04/17/2023
Special inspection requirement — Final
SAEED AINECHI
02/05/2020
Filed — Alteration
FILING TO PROPOSE HVAC UNIT SYSTEM IN RESIDENTIAL LEVEL LOCATED AT SECOND FLOOR. WORK INCLUDES NEW DUCT INSTALLATION AND NEW CONDENSER UNIT AT REAR OPEN SPACE. WORK FILED IN CONJUNCTION WITH ALTERATION TYPE 1 JOB #421217212.
Q00273231-I1
04/05/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/15/2017
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/01/2016
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/30/2016
Violation issued (ECB, open)
Elevators
10/05/2016
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/01/2016
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/10/2015
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/31/2014
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/31/2014
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/01/2012
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/28/2006
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/19/2004
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedH BUILDING MANAGEMENT INC09/25/2026
DOB NOWPlumbingPermit IssuedRISER PLBG & HTG CORP12/02/2025
DOB NOWStructuralPermit IssuedH BUILDING MANAGEMENT INC11/14/2025
DOB NOWStructuralPermit IssuedH BUILDING MANAGEMENT INC11/12/2025
DOB NOWConstruction FencePermit IssuedH BUILDING MANAGEMENT INC11/10/2025
BISOTISSUEDBENI CONSTRUCTION CO INC09/06/2017
BIS—ISSUEDBENI CONSTRUCTION CO INC08/08/2017
BISEQISSUEDBENI CONSTRUCTION CO INC07/19/2016
BISOTISSUEDBENI CONSTRUCTION CO INC07/19/2016
BISPLISSUEDCATMAN PLUMBING INC06/21/2016
BIS—ISSUEDBENI CONSTRUCTION CO INC03/29/2016
1 project · most recent 02/05/2020
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
02/05/2020——Air Conditioning Systems
Cooling
Heil N9MSE0801716A 80,000 BTU · Furnace ×1
1 project · most recent 03/25/2025
FiledStatusContractorScope
03/25/2025——5 heads
1 project · most recent 03/25/2025
Plumbing-Sprinkler Water/Sanitary
FiledStatusContractorScope
03/25/2025Permit IssuedRISER PLBG & HTG CORPPlumbing-Sprinkler, Water/Sanitary
3 projects · most recent 02/23/2026
General Wiring
FiledStatusContractorScope
02/23/2026Permit IssuedCYBER ELECTRIC LLC1 meters
02/04/2026Permit IssuedCYBER ELECTRIC LLCGeneral Wiring
06/13/2018CompletePOWER ON ELECTRIC CORP2 meters, 2 new_meters
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
02/10/2026Fire-Resistant Penetrations and JointsSAEED AINECHIspecial
02/10/2026Lighting in dwelling unitsSAEED AINECHIenergy_progress
02/10/2026Fenestration air leakageSAEED AINECHIenergy_progress
02/10/2026Fenestration areasSAEED AINECHIenergy_progress
02/10/2026Fenestration and door U-factor and product ratingsSAEED AINECHIenergy_progress
02/10/2026Air barrier - visual inspectionSAEED AINECHIenergy_progress
02/10/2026Fire-Resistance Rated ConstructionSAEED AINECHIprogress
02/10/2026FinalSAEED AINECHIprogress
02/10/2026Energy Code Compliance InspectionsSAEED AINECHIprogress
02/10/2026Tenant Protection Plan Compliance—special
02/10/2026Structural Steel - DetailsSAEED AINECHIspecial
02/10/2026Structural Cold-Formed SteelSAHAND AINECHIspecial
02/10/2026Concrete - Cast-In-PlaceSAEED AINECHIspecial
03/25/2025Fire-Resistant Penetrations and JointsSAEED AINECHIspecial
10/27/2023Concrete - Cast-In-PlaceSAEED AINECHIspecial
07/18/2023Lighting in dwelling unitsSAEED AINECHIenergy_progress
07/18/2023Fenestration air leakageSAEED AINECHIenergy_progress
07/18/2023Fenestration and door U-factor and product ratingsSAEED AINECHIenergy_progress
07/18/2023Air barrier - visual inspectionSAEED AINECHIenergy_progress
07/18/2023Energy Code Compliance InspectionsSAEED AINECHIprogress
07/18/2023Fire-Resistance Rated ConstructionSAEED AINECHIprogress
07/18/2023Fire-Resistant Penetrations and JointsSAEED AINECHIspecial
07/18/2023Fenestration areasSAEED AINECHIenergy_progress
04/18/2023Structural Steel - DetailsSAEED AINECHIspecial
04/18/2023Structural Cold-Formed SteelSAHAND AINECHIspecial
Latest 25 of 26.
▾Documents — 110 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch4
08/20/2026Q00954421-I1Request digital key ↗
08/18/2026Q01310460-I1Request digital key ↗
08/17/2026Q00860766-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/28/2026Q00273231-I1Request digital key ↗
▸Applications & Permits19
▸BISPLAN / WORK APPROVAL APPLICATION12
02/07/2022420865656Open ↗
05/02/2019421217212Open ↗
02/21/2019421217212Open ↗
Showing 3 of 12 on file for this type
▸BISWORK PERMIT APPLICATION7
09/18/2017421187566Open ↗
09/18/2017421187566Open ↗
08/10/2017421217212Open ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram3
08/17/2026Q00860766-P1Open ↗
08/13/2026Q00860766-P1Open ↗
08/13/2026Q00860766-I1Open ↗
▸Seals & Professional Certifications42
▸DOB NOWProgress Inspector Seal & Signature16
08/28/2026Q00860766-I1Open ↗
08/28/2026Q00860766-I1Open ↗
08/28/2026Q00860766-I1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
08/29/2026Q00954421-I1Open ↗
08/28/2026Q00860766-I1Open ↗
08/28/2026Q00860766-I1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION7
07/21/2016421187566Open ↗
05/20/2016421187566Open ↗
05/20/2016421187566Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/28/2026Q00273231-I1Open ↗
08/17/2026Q00860766-P1Open ↗
08/17/2026Q00860766-I1Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
05/20/2016421187566Open ↗
07/06/2010420211657Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
05/20/2016421187566Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
07/06/2010420211657Open ↗
▸Trade Schedules & Equipment5
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
03/09/2020421217212Open ↗
05/20/2016421187566Open ↗
11/09/2015421217212Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
03/09/2020421217212Open ↗
▸BISSCHEDULE B - PLUMBING1
07/08/2013420865656Open ↗
▸Safety & Tenant Protection5
▸BISSTREET TREE CHECKLIST2
05/20/2016421187566Open ↗
10/15/2015421217212Open ↗
▸DOB NOWStreet Tree Checklist2
08/17/2026Q00860766-I1Open ↗
08/13/2026Q00860766-P1Open ↗
▸BISST-1 Street Tree Checklist1
07/08/2013420865656Open ↗
▸Environmental & Asbestos5
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/15/2015421217212Open ↗
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
07/08/2013420865656Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
07/06/2010420211657Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/13/2026Q00860766-I1Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/28/2026Q00273231-I1Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
04/01/2016421217212Open ↗
03/08/2016421217212Open ↗
10/15/2015421217212Open ↗
▸BISTR8: Energy Code Progress Inspections1
07/08/2013420865656Open ↗
▸Approvals, Objections & Sign-offs3
▸BISSCHEDULE A - OCCUPANCY / USE2
12/10/2015421217212Open ↗
07/08/2013420865656Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
07/06/2010420211657Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
05/20/2016421187566Open ↗
10/15/2015421217212Open ↗
07/08/2013420865656Open ↗
▸Filing & Intake Forms7
▸BISEFILING COVER SHEET4
05/20/2016421187566Open ↗
10/15/2015421217212Open ↗
07/08/2013420865656Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION2
03/24/2020421217212Open ↗
05/02/2019421217212Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
07/06/2010420211657Open ↗
▸Other Documents9
▸DOB NOWSite Survey: Initial2
08/17/2026Q00860766-I1Open ↗
08/13/2026Q00860766-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/17/2026Q00860766-I1Open ↗
08/13/2026Q00860766-P1Open ↗
▸DOB NOWPlot Diagram2
08/17/2026Q00860766-I1Open ↗
08/13/2026Q00860766-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/17/2026Q00860766-I1Open ↗
08/13/2026Q00860766-P1Open ↗
▸BISPLOT DIAGRAM1
10/15/2015421217212Open ↗