← Back
Elevator co-op, conversion from loft/warehouse
3 GREAT JONES STREET
MANHATTAN · Greenwich Village · BIN 1008472
💬 Discuss this project
1845Year Built
5Stories
D0Building Class
M1-5/R7XZoning
13,000 sfGross Floor Area
7Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Elevator co-op, conversion from loft/warehouse · Owner of record: 3 GREAT JONES ST TENANTS CORP · 2,600 sf lot · 5 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction10p · 2 filings · 20 docs
Floor 3Under Construction13p · 1 filing · 20 docs
Floor 22p · 1 filing · 14 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
3 GREAT JONES ST TENANTS CORP503/22/2026
ANDREWS BUILDING103/22/2026
3 GREAT JONES TENANT803/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JACK GREEN ASSOCIATES308/04/2026
PULLTAB DESIGN205/08/2026
SILMAN112/09/2025
KAM CHIU CONSULTING ENGINEER, P.C.101/07/2025
CLOUDS AO LLC212/18/2024
OLA CONSULTING ENGINEERS, PC202/03/2021
HSL ARCHITECT P.C.109/03/2019
PAUL PERDEK, PROF. ENG. PLLC204/02/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EDI CONSULTING GROUP603/21/2026
JAM CONSULTANTS, INC.603/21/2026
AE DESIGN SOLUTION403/21/2026
J CALLAHAN CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EVEREST SCAFFOLDING INCGeneral Contractor707/08/2026
Z-DAR CONTRACTING INCGeneral Contractor609/13/2026
FIVE STAR P AND H CO, INCPlumbing207/08/2026
ZONE PLUMBING & HEATING CPlumbing207/08/2026
HI-TECH C.P.M. CORPGeneral Contractor107/08/2026
CCS CONSTRUCTION CONSULTGeneral Contractor107/08/2026
UNITED ELEC'L CONT'G CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JACK GREEN ASSOCIATES422308/04/2026
CHEN ENGINEERING SERVICES1826112/09/2025
KAM W CHIU1429101/07/2025
CLOUDS ARCHITECTURE OFFIC8708112/18/2024
IVAN DESIGN ENGINEERING &6983112/18/2024
AR ARCHITECT P.C.1171102/03/2021
Building Lifecycle
All (86)Filed (14)Permit Issued (14)Signed Off (4)Violation (8)Inspection (8)Objection (8)Special Inspection (30)
09/11/2026
Permit issued — Mechanical Systems
M01032961-S3-MS
08/04/2026
Filed — Alteration
MINOR MECHANICAL WORK ASSOCIATED WITH APARTMENT RENOVATION AS OER PLANS FILED HEREWITH.
M01032961-S3
06/24/2026
Special inspection requirement — Final
MELISSA BAKER
05/08/2026
Filed — Alteration
MINOR MECHANICAL WORK ASSOCIATED WITH APARTMENT RENOVATION AS OER PLANS FILED HEREWITH.
M01032961-P1
05/08/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/07/2026
Filed — Alteration
MINOR MECHANICAL WORK ASSOCIATED WITH APARTMENT RENOVATION AS OER PLANS FILED HEREWITH.
M01032961-P2
03/31/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
LAWRENCE GREEN
03/31/2026
Special inspection requirement — Final
MELISSA BAKER
03/20/2026
Permit issued — Structural
M01032961-S2-ST
02/24/2026
Permit issued — Plumbing
M01032961-S1-PL
02/04/2026
Objection resolved — Addressed
02/04/2026
Objection resolved — Addressed
02/04/2026
Objection resolved — Addressed
01/23/2026
Permit issued — General Construction
M01032961-I1-GC
12/18/2025
Objection raised — Scope
12/18/2025
Objection raised — Scope
12/18/2025
Objection raised — Scope
12/09/2025
Filed — Alteration
MINOR MECHANICAL WORK ASSOCIATED WITH APARTMENT RENOVATION AS OER PLANS FILED HEREWITH.
M01032961-S2
11/05/2025
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
HENLIA CHEN
10/29/2025
Special inspection requirement — Structural Wood Frame
HENLIA CHEN
10/29/2025
Special inspection requirement — Masonry
HENLIA CHEN
10/29/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
HENLIA CHEN
10/29/2025
Special inspection requirement — Structural Steel - Details
HENLIA CHEN
10/29/2025
Special inspection requirement — Wood – Seismic Resistance
HENLIA CHEN
10/28/2025
Special inspection requirement — Final
HENLIA CHEN
06/17/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
06/17/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/17/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/17/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/25/2025
Permit issued — Plumbing
M01032961-S1-PL
03/12/2025
Objection resolved — Addressed
03/05/2025
Objection raised — Admin
02/25/2025
Filed — Alteration
MINOR MECHANICAL WORK ASSOCIATED WITH APARTMENT RENOVATION AS OER PLANS FILED HEREWITH.
M01032961-S1
02/11/2025
Permit issued — General Construction
M01032961-I1-GC
01/07/2025
Filed — Alteration
Installation of a new split VRF system in conjunction with interior renovation and combination of the duplex apartment on the 1st & 2nd floor with a 2nd-floor apartment. Work to include MS work as per plans. No change in use, egress, or occupancy.
M01146851-S2
01/07/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Ivan Luk
12/18/2024
Filed — Alteration
Installation of a new split VRF system in conjunction with interior renovation and combination of the duplex apartment on the 1st & 2nd floor with a 2nd-floor apartment. Work to include MS work as per plans. No change in use, egress, or occupancy.
M01146851-I1
12/18/2024
Filed — Alteration
Installation of a new split VRF system in conjunction with interior renovation and combination of the duplex apartment on the 1st & 2nd floor with a 2nd-floor apartment. Work to include MS work as per plans. No change in use, egress, or occupancy.
M01146851-S1
12/04/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
OSTAP RUDAKEVYCH
12/04/2024
Special inspection requirement — Fenestration air leakage
OSTAP RUDAKEVYCH
12/04/2024
Special inspection requirement — Air barrier - visual inspection
OSTAP RUDAKEVYCH
11/25/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kam Chiu
11/25/2024
Special inspection requirement — Energy Code Compliance Inspections
Kam Chiu
11/25/2024
Special inspection requirement — HVAC-R and service water heating equipment
Kam Chiu
11/25/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Kam Chiu
11/25/2024
Special inspection requirement — Maintenance information
Kam Chiu
11/25/2024
Special inspection requirement — HVAC-R and service water heating system controls
Kam Chiu
11/22/2024
Special inspection requirement — Energy Code Compliance Inspections
OSTAP RUDAKEVYCH
11/22/2024
Special inspection requirement — Final
OSTAP RUDAKEVYCH
11/22/2024
Special inspection requirement — Mechanical Systems
Kam Chiu
11/22/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
OSTAP RUDAKEVYCH
11/22/2024
Special inspection requirement — Final
Kam Chiu
04/22/2024
Filed — Alteration
MINOR MECHANICAL WORK ASSOCIATED WITH APARTMENT RENOVATION AS OER PLANS FILED HEREWITH.
M01032961-I1
06/09/2023
Signed off — Alteration
M00418365-I1
05/24/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/24/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/23/2023
Permit issued — Plumbing
M00418365-I1-PL
10/14/2022
Signed off — Alteration
M00442216-I1
08/10/2022
Permit issued — Mechanical Systems
M00442216-I1-MS
02/24/2022
Violation issued (FDNY_NOV, closed)
Latest 60 of 86 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedZ-DAR CONTRACTING INC09/11/2026
DOB NOWStructuralPermit IssuedZ-DAR CONTRACTING INC03/20/2026
DOB NOWPlumbingPermit IssuedFIVE STAR P AND H CO, INC02/24/2026
DOB NOWGeneral ConstructionPermit IssuedZ-DAR CONTRACTING INC01/23/2026
DOB NOWPlumbingPermit IssuedFIVE STAR P AND H CO, INC03/25/2025
DOB NOWGeneral ConstructionPermit IssuedZ-DAR CONTRACTING INC02/11/2025
DOB NOWPlumbingSigned-offZONE PLUMBING & HEATING C05/23/2023
DOB NOWMechanical SystemsSigned-offCCS CONSTRUCTION CONSULT08/10/2022
DOB NOWPlumbingSigned-offZONE PLUMBING & HEATING C07/21/2021
DOB NOWSidewalk ShedSigned-offEVEREST SCAFFOLDING INC03/30/2020
DOB NOWSupported ScaffoldSigned-offEVEREST SCAFFOLDING INC03/26/2020
DOB NOWConstruction FencePermit IssuedHI-TECH C.P.M. CORP09/05/2019
DOB NOWSupported ScaffoldSigned-offEVEREST SCAFFOLDING INC04/02/2019
DOB NOWSidewalk ShedSigned-offEVEREST SCAFFOLDING INC03/30/2019
BISOTISSUEDCCS CONSTRUCTION CONSULT01/12/2023
BISOTISSUEDCCS CONSTRUCTION CONSULT01/21/2022
BISOTISSUEDCCS CONSTRUCTION CONSULT02/09/2021
BISOTISSUEDARTISAN PRESERVATION LLC02/26/2020
BISOTISSUEDHI-TECH C.P.M. CORP09/04/2019
BISOTISSUEDARTISAN PRESERVATION LLC05/10/2019
BISOTISSUEDCATH CONSTRUCTION CORP06/13/2006
BISEQISSUEDROCKLEDGE SCAFFOLD CORP04/18/2000
BISEQISSUEDROCKLEDGE SCAFFOLD CORP06/04/1999
BISPLISSUEDDEPIRTRO BROTHERS03/09/1998
BIS—ISSUEDMCDEE CONSTRUCTION CO.03/04/1998
BISBLISSUEDEMPIRE STATE FUEL OIL CORP04/01/1997
BIS—ISSUEDMCDEE CONSTRUCTION CO.01/31/1997
BISSPISSUEDBUCKMILLER AUTOMATIC SPR.CORP.06/05/1996
BISPLISSUEDDEPIRTRO BROTHERS04/16/1996
BIS—ISSUEDMCDEE CONSTRUCTION CO.04/10/1996
BISBLISSUEDEMPIRE STATE FUEL CORP.05/18/1994
2 projects · most recent 08/04/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/04/2026Permit IssuedZ-DAR CONTRACTING INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-SM48NAMHZ2 66,000 BTU · Heat Pump Outdoor ×1
01/07/2025——Heating and Air Conditioning Systems
Heat / Cool
Daikin DAIKIN, MODEL# RXTQ48TBVJUA 4 tons · Vrf Outdoor ×1
1 project · most recent 08/04/2026
Water/Sanitary
FiledStatusContractorScope
08/04/2026Permit IssuedFIVE STAR P AND H CO, INCWater/Sanitary
3 projects · most recent 07/13/2026
General Wiring
FiledStatusContractorScope
07/13/2026Permit IssuedEIS ELECTRIC CORP DBAGeneral Wiring
05/20/2021Permit IssuedUNITED ELEC'L CONT'G CORP6 meters, 1 new_meters
03/25/2019CompleteBOROWIDE ELECT'L CONTR'S—
2 projects · most recent 08/04/2026
Steel Masonry Wood
FiledStatusContractorScope
08/04/2026Permit IssuedZ-DAR CONTRACTING INCSteel, Masonry, Wood
01/07/2025——1 scope_items
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
05/08/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/17/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/17/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/17/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/17/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/24/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/24/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/19/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 30
DateRequirementInspectorRole
06/24/2026FinalMELISSA BAKERprogress
03/31/2026Fire-Resistant Penetrations and JointsLAWRENCE GREENspecial
03/31/2026FinalMELISSA BAKERprogress
11/05/2025Construction Utilizing CLT or SCL, Type IVHENLIA CHENspecial
10/29/2025Structural Wood FrameHENLIA CHENprogress
10/29/2025MasonryHENLIA CHENspecial
10/29/2025Structural Stability – Alterations of existing buildingsHENLIA CHENspecial
10/29/2025Structural Steel - DetailsHENLIA CHENspecial
10/29/2025Wood – Seismic ResistanceHENLIA CHENspecial
10/28/2025FinalHENLIA CHENprogress
01/07/2025Structural Stability – Alterations of existing buildingsIvan Lukspecial
12/04/2024Fenestration and door U-factor and product ratingsOSTAP RUDAKEVYCHenergy_progress
12/04/2024Fenestration air leakageOSTAP RUDAKEVYCHenergy_progress
12/04/2024Air barrier - visual inspectionOSTAP RUDAKEVYCHenergy_progress
11/25/2024Fire-Resistant Penetrations and JointsKam Chiuspecial
11/25/2024Energy Code Compliance InspectionsKam Chiuprogress
11/25/2024HVAC-R and service water heating equipmentKam Chiuenergy_progress
11/25/2024HVAC-R and service water piping design and insulationKam Chiuenergy_progress
11/25/2024Maintenance informationKam Chiuenergy_progress
11/25/2024HVAC-R and service water heating system controlsKam Chiuenergy_progress
11/22/2024Energy Code Compliance InspectionsOSTAP RUDAKEVYCHprogress
11/22/2024FinalOSTAP RUDAKEVYCHprogress
11/22/2024Mechanical SystemsKam Chiuspecial
11/22/2024Fire-Resistant Penetrations and JointsOSTAP RUDAKEVYCHspecial
11/22/2024FinalKam Chiuprogress
Latest 25 of 30.
▾Documents — 143 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch10
08/25/2026M01146851-S1Request digital key ↗
08/25/2026M01146851-S2Request digital key ↗
08/25/2026M01146851-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/04/2026M00442216-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
09/05/2026M00221173-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/05/2026M00145861-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Supported Scaffold1
09/05/2026M00145866-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
09/04/2026M00418365-I1Request digital key ↗
▸Applications & Permits21
▸DOB NOWLPC Approval/Permit11
08/17/2026M01032961-P2Open ↗
08/17/2026M01032961-P1Open ↗
08/17/2026M01032961-S1Open ↗
Showing 3 of 11 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION5
12/30/2020140962439Open ↗
12/13/2019123780319Open ↗
12/12/2019123780319Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION5
02/09/2021140962439Open ↗
02/27/2020140819069Open ↗
12/18/2019123780319Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications36
▸DOB NOWDPL-1: Design Professional Seal & Signature14
09/05/2026M00145861-I1Open ↗
09/05/2026M00221173-I1Open ↗
09/04/2026M00418365-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature10
09/02/2026M01032961-S2Open ↗
09/02/2026M01032961-S2Open ↗
09/02/2026M01032961-S2Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/02/2026M01032961-S2Open ↗
09/02/2026M01032961-S2Open ↗
09/01/2026M01032961-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
01/17/2020123780319Open ↗
06/11/2019123780319Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
11/27/2018140819069Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
11/27/2018140819069Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
12/30/2020140962439Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/27/2018140819069Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
06/11/2019123780319Open ↗
▸Safety & Tenant Protection6
▸BISTENANT PROTECTION PLAN AND NOTES3
02/04/2021140962439Open ↗
11/27/2018140819069Open ↗
06/11/2019123780319Open ↗
▸DOB NOWTenant Protection Plan3
09/05/2026M00221173-I1Open ↗
08/13/2026M00442216-I1Open ↗
08/13/2026M00418365-I1Open ↗
▸Environmental & Asbestos15
▸DOB NOWDEP ACP-5: Asbestos Assessment Report12
09/04/2026M00418365-I1Open ↗
08/25/2026M01146851-S1Open ↗
08/25/2026M01146851-S2Open ↗
Showing 3 of 12 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
12/30/2020140962439Open ↗
06/11/2019123780319Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
11/27/2018140819069Open ↗
▸Energy Compliance9
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
10/26/2020123780319Open ↗
10/06/2020123780319Open ↗
11/27/2018140819069Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)2
10/26/2020123780319Open ↗
10/08/2020140819069Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
06/11/2019123780319Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
11/27/2018140819069Open ↗
▸BISNYCECC EXEMPTION1
02/04/2021140962439Open ↗
▸BISNYCECC ANALYSIS1
11/27/2018140819069Open ↗
▸Inspections & Test Reports9
▸BISTECHNICAL REPORT: RESPONSIBILITY8
08/25/2023140962439Open ↗
08/25/2023140962439Open ↗
02/04/2021140962439Open ↗
Showing 3 of 8 on file for this type
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
08/25/2023140962439Open ↗
▸Approvals, Objections & Sign-offs15
▸DOB NOWLandmark Approval5
08/13/2026M01032961-I1Open ↗
08/13/2026M01032961-P1Open ↗
08/13/2026M01032961-P2Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
08/29/2023140962439Open ↗
10/26/2020123780319Open ↗
10/08/2020140819069Open ↗
▸BISLANDMARKS APPROVAL3
02/04/2021140962439Open ↗
09/04/2019123780319Open ↗
11/27/2018140819069Open ↗
▸BISLANDMARKS SIGNOFF2
08/25/2023140962439Open ↗
10/08/2020140819069Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
10/26/2020123780319Open ↗
▸BISFINAL1
08/25/2023140962439Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT3
12/30/2020140962439Open ↗
06/11/2019123780319Open ↗
11/27/2018140819069Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW33
08/23/2023140962439Open ↗
10/26/2020123780319Open ↗
10/08/2020140819069Open ↗
▸Filing & Intake Forms8
▸BISADDITIONAL INFORMATION3
02/04/2021140962439Open ↗
02/04/2021140962439Open ↗
01/17/2020123780319Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
12/30/2020140962439Open ↗
11/27/2018140819069Open ↗
▸BISBOROUGH INTAKE FORM2
12/13/2019123780319Open ↗
12/12/2019123780319Open ↗
▸BISEFILING COVER SHEET1
06/11/2019123780319Open ↗
▸Other Documents2
▸DOB NOWProof of Historic Building2
08/13/2026M01032961-I1Open ↗
08/13/2026M01032961-P1Open ↗