← Back
Miscellaneous warehouse
30-01 HARPER STREET
QUEENS · Flushing-Willets Point · BIN 4624638
💬 Discuss this project
1950Year Built
1Stories
E9Building Class
M3-1Zoning
18,800 sfGross Floor Area
3Units
Miscellaneous warehouse · Owner of record: NYC DEPARTMENT OF TRANSPORTATION · 150,975 sf lot · 0.12 FAR built · Flood zone X500
Locations of Work
Architecture
Roof2p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC DEPARTMENT OF DESIGN + CONSTRUC803/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STANTEC ARCHITECTURE INC.203/04/2025
STANTEC506/23/2023
MATRIX NEW WORLD ENGINEERING105/10/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JAM CONSULTANTS, INC.803/21/2026
KM ASSOCITES803/21/2026
Building Lifecycle
All (66)Filed (8)Objection (28)Special Inspection (30)
04/16/2025
Special inspection requirement — Maintenance information
04/16/2025
Special inspection requirement — Vertical Masonry Foundation Elements
04/16/2025
Special inspection requirement — Fire-Resistance Rated Construction
04/16/2025
Special inspection requirement — Interior lighting power
04/16/2025
Special inspection requirement — Masonry
04/16/2025
Special inspection requirement — Sprayed fire-resistant materials
04/16/2025
Special inspection requirement — Post-installed Anchors
04/16/2025
Special inspection requirement — Preliminary
04/16/2025
Special inspection requirement — Fenestration areas
04/16/2025
Special inspection requirement — Metering
04/16/2025
Special inspection requirement — Fenestration air leakage
04/16/2025
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
04/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/16/2025
Special inspection requirement — Lighting controls
04/16/2025
Special inspection requirement — Subgrade Inspections
04/16/2025
Special inspection requirement — Wall Panels, Curtain Walls, and Veneers
04/16/2025
Special inspection requirement — Energy Code Compliance Inspections
04/16/2025
Special inspection requirement — Lowest Floor Elevation
04/16/2025
Special inspection requirement — Exterior lighting power
04/16/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
04/16/2025
Special inspection requirement — Insulation placement and R values
04/16/2025
Special inspection requirement — Air barrier - visual inspection
04/16/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Michael Soltys
03/04/2025
Filed — New Building
Related mechanical work for admin building
Q08018287-P1
02/19/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
02/19/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Michael Soltys
02/19/2025
Special inspection requirement — Air barrier - visual inspection
02/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/19/2025
Special inspection requirement — Preliminary
02/19/2025
Special inspection requirement — Subgrade Inspections
02/19/2025
Special inspection requirement — Lowest Floor Elevation
01/11/2024
Objection resolved — Addressed
12/14/2023
Objection raised — Admin
10/13/2023
Objection raised — Scope
10/13/2023
Objection resolved — Addressed
08/15/2023
Objection raised — Other
08/15/2023
Objection resolved — Addressed
06/23/2023
Filed — New Building
Related mechanical work for admin building
Q08018287-S1
05/10/2023
Filed — New Building
Related mechanical work for admin building
Q08018287-S3
05/05/2023
Filed — New Building
Related mechanical work for admin building
Q08018287-S2
02/08/2023
Objection raised — Zoning
02/08/2023
Objection resolved — Addressed
02/08/2023
Objection raised — Admin
02/08/2023
Objection resolved — Addressed
02/08/2023
Objection raised — Zoning
02/08/2023
Objection resolved — Addressed
02/08/2023
Objection raised — Zoning
02/08/2023
Objection resolved — Addressed
02/08/2023
Objection raised — Fire_Protection
02/08/2023
Objection resolved — Addressed
02/08/2023
Objection raised — Inspections
02/08/2023
Objection resolved — Addressed
02/08/2023
Objection raised — Scope
02/08/2023
Objection resolved — Addressed
02/08/2023
Objection raised — Scope
02/08/2023
Objection resolved — Addressed
02/08/2023
Objection raised — Zoning
02/08/2023
Objection resolved — Addressed
02/08/2023
Objection raised — Zoning
02/08/2023
Objection resolved — Addressed
Latest 60 of 66 events.
Nothing on file for this building.
1 project · most recent 03/04/2025
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/04/2025——Air Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Mitsubishi Electric TPEADA0361AA70A /TRUZA0361KA70BA, TPEADA0361AA70A /TRUZA0361KA70BA 36,000 BTU · Split System ×2
TPEFYP054MA144A /NTXMSM060A182AA 54,000 BTU · Vrf Indoor ×1
Heating
Mitsubishi Electric TPEADA0361AA70A /TRUZA0361KA70BA, TPEADA0361AA70A /TRUZA0361KA70BA 40,000 BTU · Split System ×2
TPEFYP054MA144A /NTXMSM060A182AA 60,000 BTU · Vrf Indoor ×1
Ventilation
Greenheck SP-A90 75 CFM · Exhaust Fan ×2
SQ-120-VG 750 CFM · Exhaust Fan ×1
1 project · most recent 03/04/2025
Storm Water/Sanitary
FiledStatusContractorScope
03/04/2025——Storm, Water/Sanitary
1 project · most recent 03/04/2025
FiledStatusContractorScope
03/04/2025——1 scope_items
▾Special Inspection Requirements (DOB NOW) — 61
DateRequirementInspectorRole
04/16/2025Lighting controls—energy_progress
04/16/2025Fenestration air leakage—energy_progress
04/16/2025Maintenance information—energy_progress
04/16/2025Interior lighting power—energy_progress
04/16/2025Metering—energy_progress
04/16/2025Air barrier - visual inspection—energy_progress
04/16/2025Insulation placement and R values—energy_progress
04/16/2025Fenestration areas—energy_progress
04/16/2025Fenestration and door U-factor and product ratings—energy_progress
04/16/2025Exterior lighting power—energy_progress
04/16/2025Fire-Resistance Rated Construction—progress
04/16/2025Preliminary—progress
04/16/2025Lowest Floor Elevation—progress
04/16/2025Energy Code Compliance Inspections—progress
04/16/2025Post-installed Anchors—special
04/16/2025Fire-Resistant Penetrations and Joints—special
04/16/2025Sprayed fire-resistant materials—special
04/16/2025Subsurface Investigations (Borings/Test Pits)Michael Soltysspecial
04/16/2025Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)—special
04/16/2025Masonry—special
04/16/2025Vertical Masonry Foundation Elements—special
04/16/2025Subgrade Inspections—special
04/16/2025Wall Panels, Curtain Walls, and Veneers—special
02/19/2025Fenestration and door U-factor and product ratings—energy_progress
02/19/2025Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)—special
Latest 25 of 61.
▾Documents — 45 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/25/2026Q08015870-I1Request digital key ↗
08/25/2026Q08015877-I1Request digital key ↗
08/25/2026Q08015816-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits3
▸DOB NOWDEP Stormwater Construction Permit3
08/13/2026Q08018287-I1Open ↗
08/13/2026Q08018287-P1Open ↗
08/13/2026Q08018287-S3Open ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q08018287-P1Open ↗
08/13/2026Q08018287-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026Q08018287-P1Open ↗
08/13/2026Q08018287-I1Open ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/25/2026Q08015870-I1Open ↗
08/20/2026Q08018287-S2Open ↗
08/20/2026Q08018287-I1Open ↗
Showing 3 of 8 on file for this type
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026Q08018287-I1Open ↗
08/13/2026Q08018287-P1Open ↗
▸Inspections & Test Reports3
▸DOB NOWSOIL REPORT3
08/13/2026Q08018287-I1Open ↗
08/13/2026Q08018287-P1Open ↗
08/13/2026Q08018287-S3Open ↗
▸Approvals, Objections & Sign-offs13
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter8
08/13/2026Q08015870-I1Open ↗
08/13/2026Q08018287-S2Open ↗
08/13/2026Q08018287-S3Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)5
08/13/2026Q08018287-S2Open ↗
08/13/2026Q08018287-I1Open ↗
08/13/2026Q08018287-P1Open ↗
Showing 3 of 5 on file for this type
▸Other Documents4
▸DOB NOWSite Survey: Initial2
08/13/2026Q08018287-P1Open ↗
08/13/2026Q08018287-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q08018287-P1Open ↗
08/13/2026Q08018287-I1Open ↗