← Back
Public elementary, junior or senior high
P.S. 234
30-25 29 STREET · BIN 4007619
💬 Discuss this project
2001Year Built
4Stories
W1Building Class
R6AZoning
86,981 sfGross Floor Area
1Units
LL97 Covered2 Open Violations 1 unresolved · 1 paperwork only ▸
Public elementary, junior or senior high · Owner of record: NYC DEPARTMENT OF EDUCATION · 40,000 sf lot · 2.17 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Roof17p · 1 filing · 18 docs
Floor 43p · 1 filing · 18 docs
Floor 31p · 1 filing · 18 docs
Floor 21p · 1 filing · 18 docs
Floor 16p · 2 filings · 20 docs
CellarUnder Construction27p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC SCHOOL CONSTRUCTION1108/04/2026
NYC SCHOOL CONSTRUCTION AUTHORITY1207/08/2026
NYC DEPARTMENT OF EDUCATION103/22/2026
DEPARTMENT OF EDUCATION803/22/2026
DOE PS 234 040303/22/2026
DOE PS 234503/22/2026
DEPT OF EDUCATION PS234103/22/2026
DOE PS 234/Q234 040103/22/2026
P.S. 234 DOE303/22/2026
NY SCHOOL CONSTRUCTION AUTHORITY1603/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MAITRA ASSOCIATES209/02/2025
URBAHN ARCHITECTS109/02/2025
SHENOY ENGINEERING, PC109/02/2025
ASHOK ARCHITECTURE DESIGN, PL/208/12/2025
NYC SCA101/17/2025
NYC SCHOOL CONSTRUCTION AUTHORITY201/16/2025
360 ENGINEERING P.C.311/18/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
URBAHN ARCHITECTS403/21/2026
NYC SCHOOL CONSTRUCTION AUTHORITY303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NIKHI CONTRACTING CORPGeneral Contractor307/08/2026
PJP INSTALLERS INCGeneral Contractor307/08/2026
PATRICIO BAUTISTAElectrical103/21/2026
STEVEN HAGGERTYElectrical103/21/2026
YORK CASTLE CONSTRUCTIONGeneral Contractor107/30/2026
CHARAN ELEC'L ENTERP'S INElectrical103/22/2026
PHD SERVICES CORPPlumbing108/04/2026
JOSHUA ANDERSONElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
UNIVERSAL TESTING AND INS400308/12/2025
Building Lifecycle
All (134)Filed (12)Permit Issued (7)Signed Off (3)Violation (58)Objection (24)Special Inspection (30)
08/03/2026
Permit issued — Plumbing
Q01268184-S1-PL
07/29/2026
Permit issued — General Construction
Q01268184-I1-GC
03/04/2026
Violation issued (ECB, open)
Construction
11/04/2025
Objection resolved — Addressed
11/04/2025
Objection resolved — Addressed
10/31/2025
Objection resolved — Addressed
10/19/2025
Objection resolved — Addressed
10/19/2025
Objection resolved — Addressed
10/14/2025
Objection resolved — Addressed
10/05/2025
Special inspection requirement — Interior lighting power
NELSON LOPEZ
10/05/2025
Special inspection requirement — Lighting controls
NELSON LOPEZ
10/05/2025
Special inspection requirement — Energy Code Compliance Inspections
NELSON LOPEZ
10/05/2025
Special inspection requirement — Metering
NELSON LOPEZ
10/01/2025
Special inspection requirement — Concrete - Cast-In-Place
09/25/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
NELSON LOPEZ
09/24/2025
Special inspection requirement — Energy Code Compliance Inspections
NELSON LOPEZ
09/11/2025
Objection raised — Other
09/11/2025
Objection raised — Other
09/11/2025
Objection raised — Other
09/11/2025
Objection raised — Other
09/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NELSON LOPEZ
09/02/2025
Filed — Alteration
Minor regrading and pavement replacement of the play yard. Excavation and backfill associated with installation of storm water drainage and detention system.
Q01269906-S2
09/02/2025
Filed — Alteration
Minor regrading and pavement replacement of the play yard. Excavation and backfill associated with installation of storm water drainage and detention system.
Q01269906-S1
09/02/2025
Filed — Alteration
Minor regrading and pavement replacement of the play yard. Excavation and backfill associated with installation of storm water drainage and detention system.
Q01269906-S3
09/02/2025
Filed — Alteration
Minor regrading and pavement replacement of the play yard. Excavation and backfill associated with installation of storm water drainage and detention system.
Q01269906-I1
09/02/2025
Special inspection requirement — Energy Code Compliance Inspections
09/02/2025
Special inspection requirement — Fire-Resistance Rated Construction
09/02/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
09/02/2025
Special inspection requirement — Post-installed Anchors
08/29/2025
Special inspection requirement — Concrete - Precast
08/29/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
08/26/2025
Special inspection requirement — Post-installed Anchors
08/26/2025
Special inspection requirement — Energy Code Compliance Inspections
08/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/20/2025
Objection raised — Admin
08/20/2025
Objection raised — Other
08/19/2025
Special inspection requirement — Final
08/12/2025
Filed — Alteration
Cellar Floor Gymnasium Upgrades and Associated Boys and Girls Bathrooms Renovations.
Q01268184-S1
08/08/2025
Filed — Alteration
Cellar Floor Gymnasium Upgrades and Associated Boys and Girls Bathrooms Renovations.
Q01268184-I1
08/07/2025
Special inspection requirement — Post-installed Anchors
NELSON LOPEZ
08/07/2025
Special inspection requirement — Fire-Resistance Rated Construction
NELSON LOPEZ
08/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NELSON LOPEZ
04/16/2025
Violation issued (ECB, closed)
Construction
04/04/2025
Objection resolved — Addressed
04/01/2025
Objection resolved — Addressed
03/18/2025
Objection resolved — Addressed
01/31/2025
Objection raised — Other
01/31/2025
Objection raised — Other
01/30/2025
Objection raised — Other
01/17/2025
Filed — Alteration
REPLACE 25 ROOF DRAINS & PIPING. REPLACE THE 4" STORM LEADERS. ROTO-ROOTER & CLEANING OF STORM & AREA DRAIN LINES. RELOCATE VENT THOUGHT ROOF. PROVIDE RE-FLASHING FOR 12 VENT STACKS. REPLACE AREA DRAIN AT CELLAR. PROVIDE PIPE SUPPORTS WHERE REQUIRED
Q01109171-S1
01/16/2025
Filed — Alteration
REPLACE 25 ROOF DRAINS & PIPING. REPLACE THE 4" STORM LEADERS. ROTO-ROOTER & CLEANING OF STORM & AREA DRAIN LINES. RELOCATE VENT THOUGHT ROOF. PROVIDE RE-FLASHING FOR 12 VENT STACKS. REPLACE AREA DRAIN AT CELLAR. PROVIDE PIPE SUPPORTS WHERE REQUIRED
Q01109171-S2
01/16/2025
Special inspection requirement — Post-installed Anchors
01/16/2025
Special inspection requirement — Air barrier - visual inspection
01/16/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
01/16/2025
Special inspection requirement — Fenestration air leakage
01/16/2025
Special inspection requirement — Insulation placement and R values
01/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/15/2025
Filed — Alteration
REPLACE 25 ROOF DRAINS & PIPING. REPLACE THE 4" STORM LEADERS. ROTO-ROOTER & CLEANING OF STORM & AREA DRAIN LINES. RELOCATE VENT THOUGHT ROOF. PROVIDE RE-FLASHING FOR 12 VENT STACKS. REPLACE AREA DRAIN AT CELLAR. PROVIDE PIPE SUPPORTS WHERE REQUIRED
Q01109171-I1
01/10/2025
Special inspection requirement — Fire-Resistance Rated Construction
01/10/2025
Special inspection requirement — Energy Code Compliance Inspections
Latest 60 of 134 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedPHD SERVICES CORP08/03/2026
DOB NOWGeneral ConstructionPermit IssuedYORK CASTLE CONSTRUCTION07/29/2026
DOB NOWConstruction FenceSigned-offNIKHI CONTRACTING CORP04/12/2024
DOB NOWConstruction FenceSigned-offNIKHI CONTRACTING CORP04/14/2023
DOB NOWSupported ScaffoldSigned-offPJP INSTALLERS INC02/13/2023
DOB NOWSidewalk ShedSigned-offPJP INSTALLERS INC02/02/2023
DOB NOWConstruction FenceSigned-offNIKHI CONTRACTING CORP02/01/2023
BISPLISSUEDVARSITY PLBG AND HTG INC02/24/2025
BISOTISSUEDNIKHI CONTRACTING CORP04/02/2024
BISPLISSUEDVARSITY PLBG AND HTG INC02/27/2024
BISOTISSUEDNIKHI CONTRACTING CORP04/19/2023
BISOTISSUEDNIKHI CONTRACTING CORP03/01/2023
BISPLISSUEDVARSITY PLBG AND HTG INC03/01/2023
BISMHISSUEDTHERMO TECH MECHANICAL I*04/08/2019
BISMHISSUEDTHERMO TECH MECHANICAL I*12/21/2018
BISOTISSUEDNATIONAL ENVIROMENTAL SAFETY04/19/2012
BISPLISSUEDOLYMPIC PLBG & HTG SVC IN04/12/2012
BISOTISSUEDNYC SCHOOL CONSTRUCTION AUTHORIT12/28/2011
BISPLISSUEDDEWATERS PBG&HTGLLC05/11/2010
BISOTISSUEDULTIMA CONST, INC (SCA)05/01/2009
BISPLISSUEDDEWATERS PBG&HTGLLC04/28/2009
BISEQISSUEDROCKLEDGE SCAFFOLD CORP10/18/2005
BISPLISSUEDOLYMPIC PLUMBING & HEATING CORP08/19/2004
BISEQISSUEDPETRACCA & SONCS, INC.04/03/2003
BISEQISSUEDDORIEL SCAFFOLDING INCORPORATED01/03/2003
BISPLISSUEDOLYMPIC PLUMBING & HEATING CORP11/21/2002
BIS—ISSUEDPETRACCA & SONS, INC.10/16/2002
BISPLISSUEDAPEX MECHANICAL CORPORATION05/31/2002
BISEQISSUEDREGIONAL SCAFFOLD & HOISTING05/01/2002
BISEQISSUEDREGIONAL SCAFFOLD & HOISTING03/13/2002
BISEQISSUEDPETRACCA & SONS, INCORPORATED01/14/2002
BISEQISSUEDPETRACCA & SONCS, INC.01/02/2002
BISPLISSUEDOLYMPIC PLUMBING & HTG09/10/2001
BISEQISSUEDCONDOR ASSOCIATES LIMITED08/20/2001
BISEQISSUEDPETRACCA & SONS, INCORPORATED05/22/2001
BISPLISSUEDBROOK PLUMBING & HTG CORP06/18/1997
BISMHISSUEDKULLMAN INDUSTRIES, INCORPORATED06/18/1997
BISOTISSUEDMONARCH CONSTRUCTION CORPORATION06/13/1997
BISPLISSUEDURBAN MECHANICAL CORP12/12/1996
BISOTISSUEDD & L ASSOCIATES, INCORPORATED11/29/1996
1 project · most recent 01/17/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/17/2025——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric TRUZH0361KA00NA 36,000 BTU · Vrf Indoor ×3
TPKA0A0361KA70A 36,000 BTU · Split System ×2
TPKA0A0361KA7 36,000 BTU · Vrf Indoor ×1
Ventilation
Greenheck GB-140-7 1,555 CFM · Exhaust Fan ×2
AX-47-160-0615-A15 3,390 CFM · Exhaust Fan ×1
CUBE-180HP-10 2,500 CFM · Exhaust Fan ×1
CUBE-480-75 21,000 CFM · Exhaust Fan ×1
G-095-VG 725 CFM · Exhaust Fan ×1
G-099-VG 600 CFM · Exhaust Fan ×1
GB-140-10 1,930 CFM · Exhaust Fan ×1
GB-140-15 2,365 CFM · Exhaust Fan ×1
GB-140HP-3 675 CFM · Exhaust Fan ×1
GB-180-10 2,830 CFM · Exhaust Fan ×1
GB-180-15 2,990 CFM · Exhaust Fan ×1
GB-180HP-15 2,610 CFM · Makeup Air ×1
3 projects · most recent 09/02/2025
Storm Water/Sanitary
FiledStatusContractorScope
09/02/2025——Storm, Water/Sanitary
08/12/2025Permit IssuedPHD SERVICES CORPWater/Sanitary
01/17/2025——Storm
9 projects · most recent 08/21/2026
General Wiring Lighting
FiledStatusContractorScope
08/21/2026Permit IssuedURBAN ELECTRICAL CORPGeneral Wiring
02/05/2026CompleteWILLDAN ELECTRICAL OF NYLighting
07/28/2025CompletePRECISION ELECL CONT CORPLighting
04/25/2025CompleteGEMINI ELECTRIC CO., INC.—
06/02/2023CompleteCHARAN ELEC'L ENTERP'S IN—
02/02/2023CompleteSTANCO SYSTEM ELEC'L CONT—
01/19/2020Permit IssuedL.D.M. ELECTL CONTRS INC8 meters
05/10/2019CompleteMULTI-TECH ELECTRIC, INCGeneral Wiring
04/26/2018Permit IssuedCHARAN ELEC'L ENTERP'S INGeneral Wiring
2 projects · most recent 09/02/2025
Masonry
FiledStatusContractorScope
09/02/2025——1 scope_items
01/17/2025——Masonry
▾Special Inspection Requirements (DOB NOW) — 36
DateRequirementInspectorRole
10/05/2025Interior lighting powerNELSON LOPEZenergy_progress
10/05/2025Lighting controlsNELSON LOPEZenergy_progress
10/05/2025Energy Code Compliance InspectionsNELSON LOPEZprogress
10/05/2025MeteringNELSON LOPEZenergy_progress
10/01/2025Concrete - Cast-In-Place—special
09/25/2025HVAC-R and service water piping design and insulationNELSON LOPEZenergy_progress
09/24/2025Energy Code Compliance InspectionsNELSON LOPEZprogress
09/07/2025Fire-Resistant Penetrations and JointsNELSON LOPEZspecial
09/02/2025Energy Code Compliance Inspections—progress
09/02/2025Fire-Resistance Rated Construction—progress
09/02/2025Fire-Resistant Penetrations and Joints—special
09/02/2025Post-installed Anchors—special
08/29/2025Concrete - Precast—special
08/29/2025HVAC-R and service water piping design and insulation—energy_progress
08/26/2025Post-installed Anchors—special
08/26/2025Energy Code Compliance Inspections—progress
08/26/2025Fire-Resistant Penetrations and Joints—special
08/19/2025Final—progress
08/07/2025Post-installed AnchorsNELSON LOPEZspecial
08/07/2025Fire-Resistance Rated ConstructionNELSON LOPEZprogress
08/07/2025Fire-Resistant Penetrations and JointsNELSON LOPEZspecial
01/16/2025Post-installed Anchors—special
01/16/2025Air barrier - visual inspection—energy_progress
01/16/2025Fenestration and door U-factor and product ratings—energy_progress
01/16/2025Fenestration air leakage—energy_progress
Latest 25 of 36.
▾Documents — 74 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch12
08/21/2026Q01109171-S1Request digital key ↗
08/19/2026Q01268184-I1Request digital key ↗
08/19/2026Q01268184-S1Request digital key ↗
Showing 3 of 12 on file for this type
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
12/05/2024421899459Open ↗
▸Seals & Professional Certifications18
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/25/2026Q08038000-I1Open ↗
08/21/2026Q01109171-S1Open ↗
08/21/2026Q01109171-S2Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026Q01268184-I1Open ↗
09/01/2026Q01268184-I1Open ↗
09/01/2026Q01268184-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q01268184-I1Open ↗
09/01/2026Q01268184-S1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
12/05/2024421899459Open ↗
▸Safety & Tenant Protection3
▸DOB NOWNYCSCA - Approved Site Safety Plans3
08/13/2026Q08038005-I1Open ↗
08/13/2026Q08038000-I1Open ↗
08/13/2026Q00776233-I1Open ↗
▸Approvals, Objections & Sign-offs27
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter12
08/21/2026Q01109171-S1Open ↗
08/15/2026Q01109171-I1Open ↗
08/15/2026Q01109171-S2Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)12
08/13/2026Q01269906-S1Open ↗
08/13/2026Q01269906-S3Open ↗
08/13/2026Q01268184-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)3
08/13/2026Q01109171-S1Open ↗
08/13/2026Q01109171-S2Open ↗
08/13/2026Q01109171-I1Open ↗
▸Other Documents12
▸DOB NOWNYCSCA - BCC Plan Examination Transmittal12
08/13/2026Q01109171-I1Open ↗
08/13/2026Q01109171-S1Open ↗
08/13/2026Q08038005-I1Open ↗
Showing 3 of 12 on file for this type