← Back
Over six families without stores
30-26 43 STREET
QUEENS · Astoria (East)-Woodside (North) · BIN 4011937
💬 Discuss this project
1924Year Built
3Stories
C1Building Class
R5Zoning
5,019 sfGross Floor Area
10Units
Rent Stabilized1 Open Violation ▸
Over six families without stores · Owner of record: 30-26 43 STREET LLC · 2,725 sf lot · 1.84 FAR built · Flood zone X
Locations of Work
Plumbing
Cellar1p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
30-26 43 STREET LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/30/2023$2.2M—— → —$448/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW YORK ENGINEERING ASSOC., P.C.204/24/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEW YORK ENGINEERING ASSOCIATES P C403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEPTUNE MECHANICAL INCPlumbing307/08/2026
RENDE CONTRACTING CORPGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW YORK ENGINEERING ASSO851204/24/2023
Building Lifecycle
All (17)Filed (2)Permit Issued (3)Signed Off (2)Violation (7)Inspection (3)
12/02/2024
Violation issued (HPD, closed)
I
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/02/2024
Signed off — Alteration
Q00858932-I1
08/02/2024
Signed off — Alteration
INSTALL NEW GAS SERVICE, METER AND PIPING. INSTALL NEW WATER HEATER.
Q00859231-I1
07/02/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/17/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/12/2024
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
06/10/2024
Permit issued — Plumbing
Q00859231-I1-PL
04/12/2024
Violation issued (HPD, closed)
A
04/30/2023
Permit issued — Plumbing
Q00859231-I1-PL
04/28/2023
Permit issued — Boiler Equipment
Q00858932-I1-BE
04/24/2023
Filed — Alteration
Q00858932-I1
04/24/2023
Filed — Alteration
INSTALL NEW GAS SERVICE, METER AND PIPING. INSTALL NEW WATER HEATER.
Q00859231-I1
08/26/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/29/2015
Violation issued (ECB, closed)
Construction
04/30/2015
Violation issued (ECB, closed)
Unknown
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offNEPTUNE MECHANICAL INC06/10/2024
DOB NOWPlumbingSigned-offNEPTUNE MECHANICAL INC04/30/2023
DOB NOWBoiler EquipmentSigned-offNEPTUNE MECHANICAL INC04/28/2023
BISFBISSUEDMETRO FUEL OIL CORP05/03/2002
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
07/02/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/17/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/12/2024Pass-Final Boiler Equipment InspectionPassView ↗
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/24/2026Q00859231-I1Request digital key ↗
08/24/2026Q00858932-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026Q00858932-I1Open ↗
08/13/2026Q00859231-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/24/2026Q00858932-I1Open ↗
08/13/2026Q00859231-I1Open ↗