← Back
One family attached or semi-detached
30-33 81 STREET
QUEENS · Jackson Heights · BIN 4025156
💬 Discuss this project
1960Year Built
2Stories
A5Building Class
R4Zoning
1,520 sfGross Floor Area
1Units
One family attached or semi-detached · 2,000 sf lot · 0.76 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 12 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC205/28/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
THE GREEN PLUG LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854105/28/2025
Building Lifecycle
All (20)Filed (2)Permit Issued (1)Signed Off (1)Objection (6)Special Inspection (10)
11/05/2025
Signed off — Alteration
INSTALLATION OF PV SYSTEM ON EXISTING ROOFTOP. NO CHANGES TO EGRESS OR USE OF OCCUPANCY.
Q01231467-S1
06/03/2025
Permit issued — Solar
Q01231467-S1-SL
05/30/2025
Objection raised — Scope
05/30/2025
Objection raised — Structural
05/30/2025
Objection raised — Fire_Protection
05/30/2025
Objection raised — Zoning
05/30/2025
Objection raised — Other
05/30/2025
Objection raised — Electrical
05/28/2025
Filed — Alteration
INSTALLATION OF PV SYSTEM ON EXISTING ROOFTOP. NO CHANGES TO EGRESS OR USE OF OCCUPANCY.
Q01231467-S1
05/28/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
05/28/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
05/28/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
05/28/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
05/28/2025
Special inspection requirement — Final
TOM PETERSEN
05/27/2025
Filed — Alteration
INSTALLATION OF PV SYSTEM ON EXISTING ROOFTOP. NO CHANGES TO EGRESS OR USE OF OCCUPANCY.
Q01231467-I1
05/27/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/27/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
05/27/2025
Special inspection requirement — Energy Code Compliance Inspections
05/27/2025
Special inspection requirement — Final
05/27/2025
Special inspection requirement — Air barrier - visual inspection
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offTHE GREEN PLUG LLC06/03/2025
1 project · most recent 05/22/2025
FiledStatusContractorScope
05/22/2025CompleteL.D.M. ELECTL CONTRS INC—
1 project · most recent 05/28/2025
FiledStatusContractorScope
05/28/2025Signed-offTHE GREEN PLUG LLC40 panels, 17 kw, 800 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
05/28/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
05/28/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
05/28/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
05/28/2025Energy Code Compliance InspectionsTOM PETERSENprogress
05/28/2025FinalTOM PETERSENprogress
05/27/2025Fire-Resistant Penetrations and Joints—special
05/27/2025Structural Stability – Alterations of existing buildings—special
05/27/2025Energy Code Compliance Inspections—progress
05/27/2025Final—progress
05/27/2025Air barrier - visual inspection—energy_progress
▾Documents — 21 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026Q01231467-I1Request digital key ↗
08/20/2026Q01231467-S1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
05/15/2013420845517Open ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026Q01231467-S1Open ↗
08/25/2026Q01231467-S1Open ↗
08/25/2026Q01231467-S1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026Q01231467-I1Open ↗
08/20/2026Q01231467-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026Q01231467-S1Open ↗
08/25/2026Q01231467-S1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
05/15/2013420845517Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
05/15/2013420845517Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
05/15/2013420845517Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026Q01231467-S1Open ↗
08/20/2026Q01231467-I1Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
05/15/2013420845517Open ↗
▸Approvals, Objections & Sign-offs3
▸BISSCHEDULE A - OCCUPANCY / USE1
05/15/2013420845517Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
05/15/2013420845517Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01231467-S1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
05/15/2013420845517Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
05/15/2013420845517Open ↗