← Back
Two family converted from one family
30-88 42 STREET
QUEENS · Astoria (East)-Woodside (North) · BIN 4011310
💬 Discuss this project
1925Year Built
2Stories
B3Building Class
R5Zoning
2,288 sfGross Floor Area
2Units
Rent Stabilized7 Open Violations ▸
Two family converted from one family · 2,500 sf lot · 0.92 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 227p · 1 filing · 20 docs
Floor 128p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/13/2022$780K—— → —$341/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STUDIO AU ARCHITECTURE508/06/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
J WITKIN CONSULTING1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
M&E CONSTRUCTION CORPGeneral Contractor407/08/2026
KISHAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
OUTSOURCE SPECIAL INSPECT2827408/06/2025
Building Lifecycle
All (61)Filed (5)Permit Issued (3)Signed Off (1)Violation (10)Inspection (6)Objection (6)Special Inspection (30)
11/25/2025
Violation issued (HPD, open)
I
10/17/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/26/2025
Special inspection requirement — Mechanical Systems
JONAR MADRIAGA
08/26/2025
Special inspection requirement — Fenestration air leakage
Andrew Urbany
08/26/2025
Special inspection requirement — HVAC-R and service water heating system controls
08/26/2025
Special inspection requirement — Fenestration areas
Andrew Urbany
08/26/2025
Special inspection requirement — HVAC-R and service water heating equipment
08/26/2025
Special inspection requirement — Lighting controls
Andrew Urbany
08/26/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
08/26/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Andrew Urbany
08/26/2025
Special inspection requirement — Insulation placement and R values
Andrew Urbany
08/26/2025
Special inspection requirement — Final
Andrew Urbany
08/26/2025
Special inspection requirement — Fire-Resistance Rated Construction
Andrew Urbany
08/06/2025
Filed — Alteration CO
REMOVAL AND INSTALLLATION OF PLUMIBING FIXTURES AS PER PLANS FILED HEREWITH.
Q00813109-P3
08/01/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
08/01/2025
Special inspection requirement — Mechanical Systems
JONAR MADRIAGA
08/01/2025
Special inspection requirement — Final
Andrew Urbany
08/01/2025
Special inspection requirement — Fire-Resistance Rated Construction
Andrew Urbany
08/01/2025
Special inspection requirement — Lighting controls
Andrew Urbany
08/01/2025
Special inspection requirement — HVAC-R and service water heating equipment
08/01/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Andrew Urbany
08/01/2025
Special inspection requirement — Fenestration air leakage
Andrew Urbany
08/01/2025
Special inspection requirement — Fenestration areas
Andrew Urbany
08/01/2025
Special inspection requirement — Insulation placement and R values
Andrew Urbany
08/01/2025
Special inspection requirement — HVAC-R and service water heating system controls
07/29/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/09/2025
Signed off — Alteration CO
REMOVAL AND INSTALLLATION OF PLUMIBING FIXTURES AS PER PLANS FILED HEREWITH.
Q00813109-S1
06/18/2025
Objection resolved — Addressed
06/17/2025
Objection resolved — Addressed
05/09/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/04/2024
Violation issued (HPD, open)
I
12/02/2024
Objection resolved — Addressed
11/19/2024
Objection raised — Zoning
11/19/2024
Objection raised — Zoning
11/19/2024
Objection raised — Structural
11/11/2024
Filed — Alteration CO
REMOVAL AND INSTALLLATION OF PLUMIBING FIXTURES AS PER PLANS FILED HEREWITH.
Q00813109-P2
11/04/2024
Special inspection requirement — Mechanical Systems
JONAR MADRIAGA
11/04/2024
Special inspection requirement — HVAC-R and service water heating system controls
11/04/2024
Special inspection requirement — Lighting controls
Andrew Urbany
11/04/2024
Special inspection requirement — Fenestration areas
Andrew Urbany
11/04/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
11/04/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Andrew Urbany
11/04/2024
Special inspection requirement — HVAC-R and service water heating equipment
11/04/2024
Special inspection requirement — Insulation placement and R values
Andrew Urbany
10/02/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/26/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/23/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
02/07/2024
Permit issued — Mechanical Systems
Q00813109-I1-GC-CX
11/30/2023
Permit issued — Plumbing
Q00813109-S1-PL
11/29/2023
Violation issued (HPD, closed)
I
11/20/2023
Filed — Alteration CO
REMOVAL AND INSTALLLATION OF PLUMIBING FIXTURES AS PER PLANS FILED HEREWITH.
Q00813109-S1
11/16/2023
Permit issued — Mechanical Systems
Q00813109-I1-GC-CX
11/03/2023
Filed — Alteration CO
REMOVAL AND INSTALLLATION OF PLUMIBING FIXTURES AS PER PLANS FILED HEREWITH.
Q00813109-P1
05/23/2023
Filed — Alteration CO
REMOVAL AND INSTALLLATION OF PLUMIBING FIXTURES AS PER PLANS FILED HEREWITH.
Q00813109-I1
10/30/2018
Violation issued (HPD, closed)
I
10/15/2012
Violation issued (HPD, open)
B
10/15/2012
Violation issued (HPD, open)
B
10/15/2012
Violation issued (HPD, open)
B
10/15/2012
Violation issued (HPD, open)
B
10/15/2012
Violation issued (HPD, open)
B
Latest 60 of 61 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedM&E CONSTRUCTION CORP02/07/2024
DOB NOWPlumbingSigned-offN AND S PLUMBING INC11/30/2023
DOB NOWMechanical SystemsPermit IssuedM&E CONSTRUCTION CORP11/16/2023
1 project · most recent 08/06/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/06/2025Permit IssuedM&E CONSTRUCTION CORPHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric PUMY-HP48NKMU1 - MITSUBISHI 48,000 BTU · Vrf Outdoor ×6
1 project · most recent 08/06/2025
Gas Water/Sanitary
FiledStatusContractorScope
08/06/2025Signed-offKISHAN PLUMBING INCGas, Water/Sanitary
1 project · most recent 02/03/2025
General Wiring
FiledStatusContractorScope
02/03/2025CompleteACCURATE ELEC'L CORP.General Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
10/17/2025Pass-Final CND-Occupancy InspectionPassView ↗
07/29/2025Pass-Final CND-Occupancy InspectionPassView ↗
05/09/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/02/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/26/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/23/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 33
DateRequirementInspectorRole
08/26/2025Mechanical SystemsJONAR MADRIAGAspecial
08/26/2025Fenestration air leakageAndrew Urbanyenergy_progress
08/26/2025HVAC-R and service water heating system controls—energy_progress
08/26/2025Fenestration areasAndrew Urbanyenergy_progress
08/26/2025HVAC-R and service water heating equipment—energy_progress
08/26/2025Lighting controlsAndrew Urbanyenergy_progress
08/26/2025HVAC-R and service water piping design and insulation—energy_progress
08/26/2025Fenestration and door U-factor and product ratingsAndrew Urbanyenergy_progress
08/26/2025Insulation placement and R valuesAndrew Urbanyenergy_progress
08/26/2025FinalAndrew Urbanyprogress
08/26/2025Fire-Resistance Rated ConstructionAndrew Urbanyprogress
08/01/2025HVAC-R and service water piping design and insulation—energy_progress
08/01/2025Mechanical SystemsJONAR MADRIAGAspecial
08/01/2025FinalAndrew Urbanyprogress
08/01/2025Fire-Resistance Rated ConstructionAndrew Urbanyprogress
08/01/2025Lighting controlsAndrew Urbanyenergy_progress
08/01/2025HVAC-R and service water heating equipment—energy_progress
08/01/2025Fenestration and door U-factor and product ratingsAndrew Urbanyenergy_progress
08/01/2025Fenestration air leakageAndrew Urbanyenergy_progress
08/01/2025Fenestration areasAndrew Urbanyenergy_progress
08/01/2025Insulation placement and R valuesAndrew Urbanyenergy_progress
08/01/2025HVAC-R and service water heating system controls—energy_progress
11/04/2024Mechanical SystemsJONAR MADRIAGAspecial
11/04/2024HVAC-R and service water heating system controls—energy_progress
11/04/2024Lighting controlsAndrew Urbanyenergy_progress
Latest 25 of 33.
▾Documents — 55 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/21/2026Q00813109-P1Request digital key ↗
08/21/2026Q00813109-I1Request digital key ↗
08/21/2026Q00813109-P3Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records8
▸DOB NOWZoning Exhibit form (1-5)4
08/13/2026Q00813109-P3Open ↗
08/13/2026Q00813109-P1Open ↗
08/13/2026Q00813109-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram4
08/13/2026Q00813109-I1Open ↗
08/13/2026Q00813109-P2Open ↗
08/13/2026Q00813109-P3Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature9
09/01/2026Q00813109-P3Open ↗
09/01/2026Q00813109-P3Open ↗
09/01/2026Q00813109-P3Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/13/2026Q00813109-S1Open ↗
08/13/2026Q00813109-I1Open ↗
08/13/2026Q00813109-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026Q00813109-P3Open ↗
08/28/2026Q00813109-I1Open ↗
08/27/2026Q00813109-P2Open ↗
▸Safety & Tenant Protection4
▸DOB NOWStreet Tree Checklist4
08/13/2026Q00813109-P3Open ↗
08/13/2026Q00813109-P2Open ↗
08/13/2026Q00813109-P1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/13/2026Q00813109-P1Open ↗
08/13/2026Q00813109-I1Open ↗
08/13/2026Q00813109-P3Open ↗
Showing 3 of 5 on file for this type
▸Other Documents16
▸DOB NOWProperty Ownership Certification4
08/13/2026Q00813109-P2Open ↗
08/13/2026Q00813109-I1Open ↗
08/13/2026Q00813109-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSite Survey: Initial4
08/13/2026Q00813109-P3Open ↗
08/13/2026Q00813109-P2Open ↗
08/13/2026Q00813109-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/13/2026Q00813109-P3Open ↗
08/13/2026Q00813109-P1Open ↗
08/13/2026Q00813109-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlot Diagram4
08/13/2026Q00813109-I1Open ↗
08/13/2026Q00813109-P1Open ↗
08/13/2026Q00813109-P2Open ↗