← Back
Miscellaneous two family
30 WEST 11 STREET
MANHATTAN · BIN 1009529
💬 Discuss this project
1841Year Built
3Stories
B9Building Class
R6Zoning
5,670 sfGross Floor Area
2Units
0 Open Violations
Miscellaneous two family · Owner of record: 30 WEST 11 STREET, LLC · 2,132 sf lot · 2.66 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingCivilGeneral
Roof5p · 2 filings · 20 docs
Penthouse6p · 1 filing · 20 docs
Floor 33p · 3 filings · 20 docs
Floor 2
Floor 1
Cellar4p · 1 filing · 20 docs
Basement1p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
30 WEST 11TH STREET106/07/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/09/2025$9.7M—— → —$1,711/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOCCI ENGINEERING PLLC206/18/2026
THE BROOKLYN STUDIO205/05/2026
CASEWORKS ARCHITECT, PLLC508/19/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MUNICIPAL BUILDING CONSULTANTS503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CHRISTOPHER SCHAEFERElectrical103/21/2026
AWA GOSK GROUP INCGeneral Contractor106/07/2026
PETER G CONSTRUCTION INCGeneral Contractor107/08/2026
DPH PLUMBING & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CITY-WIDE TESTING INC416106/18/2026
THE BROOKLYN STUDIO OF AR2684105/05/2026
VALERIO ASSOCIATES, P.C.1379201/16/2020
Building Lifecycle
All (71)Filed (9)Permit Issued (3)Signed Off (2)Violation (5)Objection (22)Special Inspection (30)
07/29/2026
Objection resolved — Resolved
07/29/2026
Objection resolved — Resolved
07/29/2026
Objection resolved — Resolved
07/29/2026
Objection resolved — Resolved
07/15/2026
Objection raised — Scope
07/15/2026
Objection raised — Cost
07/14/2026
Objection raised — Scope
07/14/2026
Objection raised — Cost
06/18/2026
Filed — Alteration CO
This subsequent filing is being filed for the mechanical work at the subject premises. There are no change in use, egress or occupancy under this application.
M01357167-S2
06/18/2026
Filed — Alteration CO
This subsequent filing is being filed for the mechanical work at the subject premises. There are no change in use, egress or occupancy under this application.
M01357167-S1
06/18/2026
Objection resolved — Resolved
06/18/2026
Objection resolved — Resolved
06/18/2026
Objection resolved — Resolved
06/18/2026
Objection resolved — Resolved
06/05/2026
Permit issued — General Construction
M01371570-I1-GC
05/27/2026
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
ELIAS RASABI
05/27/2026
Special inspection requirement — Structural Wood Frame
ELIAS RASABI
05/27/2026
Special inspection requirement — Structural Steel - High Strength Bolting
ELIAS RASABI
05/27/2026
Special inspection requirement — Post-installed Anchors
ELIAS RASABI
05/27/2026
Special inspection requirement — Structural Steel - Welding
ELIAS RASABI
05/21/2026
Objection raised — Energy
05/21/2026
Objection raised — Zoning
05/21/2026
Objection raised — Scope
05/21/2026
Objection raised — Cost
05/21/2026
Special inspection requirement — Electrical motors and elevators
05/21/2026
Special inspection requirement — Maintenance information
05/05/2026
Filed — Alteration CO
This subsequent filing is being filed for the mechanical work at the subject premises. There are no change in use, egress or occupancy under this application.
M01357167-I1
05/01/2026
Special inspection requirement — Air barrier - visual inspection
05/01/2026
Special inspection requirement — Lighting in dwelling units
05/01/2026
Special inspection requirement — Exterior lighting power
05/01/2026
Special inspection requirement — Fenestration air leakage
05/01/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Brendan Coburn
05/01/2026
Special inspection requirement — Energy Code Compliance Inspections
Brendan Coburn
05/01/2026
Special inspection requirement — Fire-Resistance Rated Construction
Brendan Coburn
05/01/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
05/01/2026
Special inspection requirement — Metering
05/01/2026
Special inspection requirement — Fenestration areas
05/01/2026
Special inspection requirement — Interior lighting power
05/01/2026
Special inspection requirement — Protection of exposed foundation insulation
05/01/2026
Special inspection requirement — Insulation placement and R values
05/01/2026
Special inspection requirement — Lighting controls
05/01/2026
Special inspection requirement — Chimneys and vents
Brendan Coburn
05/01/2026
Special inspection requirement — Vestibules
04/06/2026
Filed — Alteration
Application filed for temporary structure. Non habitable rooftop mockup solely for review & approval by the LPC .No change in use, egress or occupancy.
M01371570-I1
03/13/2026
Special inspection requirement — Final
Brendan Coburn
02/11/2026
Special inspection requirement — Final
02/11/2026
Special inspection requirement — Footing and Foundation
02/10/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
ELIAS RASABI
02/10/2026
Special inspection requirement — Final
ELIAS RASABI
02/10/2026
Special inspection requirement — Structural Steel - Details
ELIAS RASABI
02/10/2026
Special inspection requirement — Masonry
ELIAS RASABI
02/26/2021
Signed off — Alteration
structural repairs to each floor as per plans filed herewith. No change to use, egress or occupancy.
M00189061-I1
02/03/2021
Signed off — Alteration
installation of Plumbing fixtures as per plans filed herewith.
M00207127-I1
08/19/2020
Filed — Alteration
installation of Plumbing fixtures as per plans filed herewith.
M00207127-P2
07/21/2020
Filed — Alteration
installation of Plumbing fixtures as per plans filed herewith.
M00207127-P1
02/06/2020
Permit issued — Plumbing
M00207127-I1-PL
01/27/2020
Objection resolved — Addressed
01/17/2020
Objection raised — Admin
01/16/2020
Filed — Alteration
structural repairs to each floor as per plans filed herewith. No change to use, egress or occupancy.
M00189061-P1
12/09/2019
Filed — Alteration
installation of Plumbing fixtures as per plans filed herewith.
M00207127-I1
Latest 60 of 71 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offAWA GOSK GROUP INC06/05/2026
DOB NOWPlumbingSigned-offDPH PLUMBING & HTG CORP02/06/2020
DOB NOWStructuralSigned-offPETER G CONSTRUCTION INC11/07/2019
BISOTISSUEDPETER G CONSTRUCTION INC12/19/2019
BIS—ISSUEDBEN FISHBEIN04/07/1993
1 project · most recent 06/18/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/18/2026——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-SM36NLHZ 3 tons · Condensing Unit ×1
MXZ-SM48NLHZ 4 tons · Condensing Unit ×1
MZX-SM48NLHZ 4 tons · Condensing Unit ×1
SUZ-AA18NLHZ 20,000 BTU · Condensing Unit ×1
Ventilation
Pennbarry FX13S 400 CFM · Exhaust Fan ×1
1 project · most recent 06/18/2026
Sprinkler System
FiledStatusContractorScope
06/18/2026——Sprinkler System
1 project · most recent 06/18/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
06/18/2026——Gas, Storm, Water/Sanitary
1 project · most recent 12/22/2020
General Wiring
FiledStatusContractorScope
12/22/2020CompleteEVS ELECTRIC CORPGeneral Wiring
1 project · most recent 06/18/2026
Steel Concrete Masonry Wood
FiledStatusContractorScope
06/18/2026——Steel, Concrete, Masonry, Wood
▾Special Inspection Requirements (DOB NOW) — 38
DateRequirementInspectorRole
05/27/2026Construction Utilizing CLT or SCL, Type IVELIAS RASABIspecial
05/27/2026Structural Wood FrameELIAS RASABIprogress
05/27/2026Structural Steel - High Strength BoltingELIAS RASABIspecial
05/27/2026Post-installed AnchorsELIAS RASABIspecial
05/27/2026Structural Steel - WeldingELIAS RASABIspecial
05/21/2026Electrical motors and elevators—energy_progress
05/21/2026Maintenance information—energy_progress
05/01/2026Air barrier - visual inspection—energy_progress
05/01/2026Lighting in dwelling units—energy_progress
05/01/2026Exterior lighting power—energy_progress
05/01/2026Fenestration air leakage—energy_progress
05/01/2026Fire-Resistant Penetrations and JointsBrendan Coburnspecial
05/01/2026Energy Code Compliance InspectionsBrendan Coburnprogress
05/01/2026Fire-Resistance Rated ConstructionBrendan Coburnprogress
05/01/2026Fenestration and door U-factor and product ratings—energy_progress
05/01/2026Metering—energy_progress
05/01/2026Fenestration areas—energy_progress
05/01/2026Interior lighting power—energy_progress
05/01/2026Protection of exposed foundation insulation—energy_progress
05/01/2026Insulation placement and R values—energy_progress
05/01/2026Lighting controls—energy_progress
05/01/2026Chimneys and ventsBrendan Coburnspecial
05/01/2026Vestibules—energy_progress
03/13/2026FinalBrendan Coburnprogress
02/11/2026Final—progress
Latest 25 of 38.
▾Documents — 79 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch10
09/06/2026M01357167-S2Request digital key ↗
09/06/2026M01357167-S1Request digital key ↗
09/06/2026M01357167-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸DOB NOWPlans/Sketch - Plumbing3
09/04/2026M00207127-I1Request digital key ↗
08/15/2026M00207127-P2Request digital key ↗
08/15/2026M00207127-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Structural2
08/15/2026M00189061-P1Request digital key ↗
08/15/2026M00189061-I1Request digital key ↗
▸Applications & Permits14
▸DOB NOWLPC Approval/Permit11
08/18/2026M01371570-I1Open ↗
08/17/2026M01357167-S4Open ↗
08/17/2026M01357167-S3Open ↗
Showing 3 of 11 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
06/26/2025100482602Open ↗
06/24/2025100482602Open ↗
11/21/2019123790852Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/17/2026M01357167-I1Open ↗
▸Seals & Professional Certifications20
▸DOB NOWDPL-1: Design Professional Seal & Signature12
09/05/2026M00189061-I1Open ↗
09/05/2026M00189061-P1Open ↗
08/18/2026M01371570-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026M00189061-I1Open ↗
09/01/2026M00189061-I1Open ↗
09/01/2026M00189061-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
09/21/2026M01371570-I1Open ↗
09/01/2026M00189061-I1Open ↗
08/26/2026M01357167-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
11/19/2019123790852Open ↗
▸Safety & Tenant Protection7
▸DOB NOWTenant Protection Plan5
08/15/2026M00189061-P1Open ↗
08/15/2026M00189061-I1Open ↗
08/13/2026M00207127-P2Open ↗
Showing 3 of 5 on file for this type
▸BISTenant Protection Plan and Notes1
11/19/2019123790852Open ↗
▸DOB NOWStreet Tree Checklist1
08/17/2026M01357167-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/15/2026M00189061-P1Open ↗
08/15/2026M00189061-I1Open ↗
08/13/2026M00207127-P2Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/19/2019123790852Open ↗
▸Energy Compliance3
▸BISAS-BUILT ENERGY ANALYSIS1
02/16/2021123790852Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
02/16/2021123790852Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
11/19/2019123790852Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
02/16/2021123790852Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
02/16/2021123790852Open ↗
▸BISLANDMARKS APPROVAL1
12/05/2019123790852Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
02/16/2021123790852Open ↗
11/19/2019123790852Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
07/22/2020123790852Open ↗
▸BISEFILING COVER SHEET1
11/19/2019123790852Open ↗
▸Other Documents6
▸DOB NOWPlot Diagram2
08/17/2026M01357167-I1Open ↗
08/14/2026M01357167-S2Open ↗
▸BISUnknown1
12/19/2019123790852Open ↗
▸DOB NOWProperty Ownership Certification1
08/17/2026M01357167-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/17/2026M01357167-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/17/2026M01357167-I1Open ↗