| Owner | Filings | Most Recent |
|---|---|---|
| ROGERS EQUITIES | 16 | 08/26/2026 |
| HEXAGON INDUSTRIES | 6 | 03/22/2026 |
| 30-01 NORTHERN BLVD | 11 | 03/22/2026 |
| 30-01 NORTHERN BLV LLC | 1 | 03/22/2026 |
| THE OWNER OF | 1 | 03/22/2026 |
| PEHINELLI ELEC. CO. INC. | 1 | 03/22/2026 |
| BRAVON CAPITAL | 10 | 03/21/2026 |
| SCHWARTZ | 1 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 02/28/2025 | $4.8M | — | — → — | $522/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| ADROIT ENGINEERING PLLC | 3 | 02/16/2026 |
| BLACK SHEEP ENGINEERING GROUP | 2 | 12/15/2025 |
| ADVANCED ENGINEERING & INSPECT. PLL | 4 | 08/21/2025 |
| ELEVATED ENGINEERING NYC | 3 | 07/01/2025 |
| NA | 2 | 06/10/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| EXPEDITING 4 U | 9 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| ROGERS DEVELOPERS GRP LLC | General Contractor | 4 | 08/26/2026 |
| HEXAGON INDUSTRIES INC | General Contractor | 3 | 03/21/2026 |
| METFLOW FIRE CONTROL LLC | Fire Protection | 1 | 07/08/2026 |
| COLGATE ENTERPRISE CORP | General Contractor | 1 | 04/09/2026 |
| N TECH DESIGN OF AMERICA | General Contractor | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ADROIT ENGINEERING PLLC | 8885 | 2 | 02/16/2026 |
| HRF SERVICES CORP | 5616 | 8 | 08/21/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Construction Fence | Permit Issued | ROGERS DEVELOPERS GRP LLC | 08/25/2026 |
| DOB NOW | Full Demolition | Permit Issued | N TECH DESIGN OF AMERICA | 05/12/2026 |
| DOB NOW | Standpipe | Permit Issued | METFLOW FIRE CONTROL LLC | 01/28/2026 |
| DOB NOW | Full Demolition | Permit Issued | HEXAGON INDUSTRIES INC | 12/29/2025 |
| DOB NOW | Sidewalk Shed | Permit Issued | COLGATE ENTERPRISE CORP | 12/17/2025 |
| DOB NOW | Construction Fence | Permit Issued | ROGERS DEVELOPERS GRP LLC | 10/30/2025 |
| BIS | OT | ISSUED | JJSL DEVELOPMENT INC | 12/22/2011 |
| BIS | OT | ISSUED | PANE STONE CONSTRUCTION | 01/19/2011 |
| BIS | PL | ISSUED | H2O CONCEPT PLBG & HTG CO | 03/18/2010 |
| BIS | OT | ISSUED | DISANO DEMOLITION CO, INC | 05/12/2009 |
| BIS | — | ISSUED | PRETEE CONSTR | 12/07/2006 |
| BIS | MH | ISSUED | PRETEE CONSTRUCTION | 08/23/2006 |
| BIS | PL | ISSUED | CATMAN PLUMBING INC | 03/03/2006 |
| BIS | OT | ISSUED | PRETEE CONSTRUCTION | 01/18/2006 |
| BIS | EQ | ISSUED | L&B CONSTR. NY INC | 01/10/2006 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 08/21/2025 | — | — | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Mitsubishi Electric MXZ-SM36NAM2-U1 36,000 BTU · Condensing Unit ×27 MXZ-SM48NAM2-U1 48,000 BTU · Condensing Unit ×13 SUZ-KA30NA2.TH 27,000 BTU · Condensing Unit ×4 SUZ-KA36NA2.TH 33,000 BTU · Condensing Unit ×2 MUZ-GS12NA 12,000 BTU · Condensing Unit ×1 Heating Mitsubishi Electric MXZ-SM36NAM2-U1 41,000 BTU · Condensing Unit ×27 MXZ-SM48NAM2-U1 50,000 BTU · Condensing Unit ×13 SUZ-KA30NA2.TH 30,000 BTU · Condensing Unit ×4 SUZ-KA36NA2.TH 33,400 BTU · Condensing Unit ×2 MUZ-GS12NA 14,400 BTU · Condensing Unit ×1 Ventilation Greenheck ERVe-45-15H 3,775 CFM · Erv ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/21/2025 | Permit Issued | METFLOW FIRE CONTROL LLC | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/21/2025 | — | — | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/20/2026 | Permit Issued | POWER DIRECT ELECTRIC INC | — |
| 12/18/2025 | Permit Issued | POWER DIRECT ELECTRIC INC | General Wiring |
| 12/18/2025 | Permit Issued | POWER DIRECT ELECTRIC INC | 1 meters, 1 new_meters |
| 12/03/2025 | Permit Issued | NASH ELECTRIC SERVICES IN | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/21/2025 | Permit Issued | METFLOW FIRE CONTROL LLC | Concrete, Masonry |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 12/15/2025 | Permit Issued | COLGATE ENTERPRISE CORP | Sidewalk Shed |
| 07/28/2025 | Permit Issued | ROGERS DEVELOPERS GRP LLC | Fence |
| 06/10/2025 | Permit Issued | ROGERS DEVELOPERS GRP LLC | Fence |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 04/28/2026 | Structural Stability – Alterations of existing Buildings | DUY HOANG | special |
| 02/02/2026 | Structural Stability – Alterations of existing Buildings | DUY HOANG | special |
| 01/08/2026 | Combustible Exterior Wall Coverings | SHAHRIAR QUAYYUM | special |
| 07/22/2025 | Fire-Resistant Penetrations and Joints | SHAHRIAR QUAYYUM | special |
| 06/25/2025 | Standpipe Systems | SHAHRIAR QUAYYUM | special |
| 03/27/2025 | Air barrier - visual inspection | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Fenestration areas | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Air barrier continuity plan testing | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Lighting controls | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Insulation placement and R values | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Interior lighting power | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Electrical motors and elevators | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Fire-Resistant Penetrations and Joints | SHAHRIAR QUAYYUM | special |
| 03/27/2025 | Metering | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Exterior lighting power | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Fenestration air leakage | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Protection of exposed foundation insulation | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Maintenance information | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Fenestration and door U-factor and product ratings | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Lighting in dwelling units | SHAHRIAR QUAYYUM | energy_progress |
| 03/27/2025 | Energy Code Compliance Inspections | SHAHRIAR QUAYYUM | progress |
| 03/27/2025 | Fire-Resistance Rated Construction | SHAHRIAR QUAYYUM | progress |