| Owner | Filings | Most Recent |
|---|---|---|
| N Y C HOUSING AUTHORITY | 1 | 03/22/2026 |
| NYC PARKS DEPARTMENT | 1 | 03/21/2026 |
| JASCO | 2 | 03/21/2026 |
| NYC DEPT DESIGN CONSTRUCTION | 2 | 03/21/2026 |
| NYC DEPT OF DESIGN & CONST. | 2 | 03/21/2026 |
| NYCDDC | 1 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| LANGAN ENG, ENV, SURVEY, LARCH, DPC | 1 | 07/31/2025 |
| JACOB FEINBERG KATZ & MICHAELI CONS | 3 | 02/14/2025 |
| DATTNER ARCHITECTS | 3 | 11/04/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| WILLIAM VITACCO ASSOCIATES | 14 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| INNER CITY CONTRACTING | Electrical | 1 | 03/21/2026 |
| KLEIN WILLIAM | Electrical | 1 | 03/21/2026 |
| MICHAEL BAPTISTE | Electrical | 1 | 03/21/2026 |
| RONALD TESTA, JR. | Electrical | 1 | 03/21/2026 |
| TESTA ELECTRIC CO., INC | Electrical | 1 | 03/22/2026 |
| WILLIAM KLEIN | Electrical | 1 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| JPC LOGISTICS DBA JPCL EN | 351 | 7 | 07/31/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| BIS | EQ | RE-ISSUED | JASCO, INC | 10/04/2017 |
| BIS | FP | ISSUED | EMDI LTD | 11/26/2012 |
| BIS | OT | ISSUED | THE FRANKLIN COMANY CONT* | 09/13/2012 |
| BIS | OT | RE-ISSUED | THE FRANKLIN COMANY CONT* | 09/05/2012 |
| BIS | FP | ISSUED | FIRE GUARD OF LONG ISLAND | 02/07/2007 |
| BIS | BL | ISSUED | PETER AGLIARDO JR | 05/16/2001 |
| BIS | OT | ISSUED | ENSA ENVIROMENTAL, INC. | 02/14/1996 |
| BIS | BL | ISSUED | S.J. FUEL CO., INC | 07/29/1993 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/31/2025 | — | — | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric PEFY-P54NMAU-E4 54,000 BTU · Vrf Indoor ×6 PEFY-P36NMAU-E4 36,000 BTU · Vrf Indoor ×5 PKA-A24KA7.TH 24,000 BTU · Fan Coil Indoor ×2 PLFY-P08NFMU-ER1.TH 54,000 BTU · Vrf Indoor ×2 PUY-A24NHA7 24,000 BTU · Condensing Unit ×2 PEFY-P48NMAU-E4 48,000 BTU · Vrf Indoor ×1 PEFY-P72NMHXU-E 72,000 BTU · Vrf Indoor ×1 PLFY-EP24NEMU1-E.TH 24,000 BTU · Vrf Indoor ×1 PURY-EP216TNU-A 216,000 BTU · Vrf Outdoor ×1 PURY-EP432TSNU-A 36 tons · Vrf Outdoor ×1 Trane OADG015C1 181,800 BTU · Doas ×1 Ventilation Greenheck SQ-80-VG 300 CFM · Exhaust Fan ×5 QEI-24 8,600 CFM · Exhaust Fan ×1 SQ-90-VG 350 CFM · Exhaust Fan ×1 USF-6 600 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/31/2025 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/31/2025 | — | — | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/08/2018 | Permit Issued | TESTA ELECTRIC CO., INC | 1 meters, 1 new_meters |
| 04/25/2018 | Permit Issued | KLK ELECTRIC, INC | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/31/2025 | — | — | Steel, Concrete |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 01/27/2025 | HVAC-R and service water heating system controls | Asma Hashmi | energy_progress |
| 01/27/2025 | Shutoff dampers | Asma Hashmi | energy_progress |
| 01/27/2025 | Maintenance information | Asma Hashmi | energy_progress |
| 01/27/2025 | HVAC-R and service water piping design and insulation | Asma Hashmi | energy_progress |
| 01/27/2025 | Exhaust and Vent Systems in Plenums and Ducts | Asma Hashmi | special |
| 01/27/2025 | Post-installed Anchors | Asma Hashmi | special |
| 01/27/2025 | Duct leakage testing, insulation and design | Asma Hashmi | energy_progress |
| 01/27/2025 | HVAC-R and service water heating equipment | Asma Hashmi | energy_progress |
| 10/22/2024 | Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable) | Asma Hashmi | special |
| 10/22/2024 | Vestibules | Asma Hashmi | energy_progress |
| 10/22/2024 | Energy Code Compliance Inspections | Asma Hashmi | progress |
| 10/13/2024 | Subsurface Conditions – Fill Placement & In-Place Density | Asma Hashmi | special |
| 10/13/2024 | Excavations - Sheeting, Shoring, and Bracing | Asma Hashmi | special |
| 10/10/2024 | Fire-Resistant Penetrations and Joints | Asma Hashmi | special |
| 10/10/2024 | Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable) | Asma Hashmi | special |
| 10/10/2024 | Final | Asma Hashmi | progress |
| 10/10/2024 | Mechanical Systems | Asma Hashmi | special |
| 11/01/2022 | Protection of exposed foundation insulation | Asma Hashmi | energy_progress |
| 11/01/2022 | Air barrier - visual inspection | Asma Hashmi | energy_progress |
| 11/01/2022 | Lighting controls | Asma Hashmi | energy_progress |
| 11/01/2022 | Fenestration areas | Asma Hashmi | energy_progress |
| 11/01/2022 | Lowest Floor Elevation | Asma Hashmi | progress |
| 11/01/2022 | Exterior lighting power | Asma Hashmi | energy_progress |
| 11/01/2022 | Fenestration and door U-factor and product ratings | Asma Hashmi | energy_progress |
| 11/01/2022 | Fenestration air leakage | Asma Hashmi | energy_progress |