← Back
One family attached or semi-detached
3008 AVENUE T
BROOKLYN · BIN 3199108
💬 Discuss this project
1930Year Built
2Stories
A5Building Class
R4Zoning
1,152 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One family attached or semi-detached · 1,850 sf lot · 0.62 FAR built · Flood zone X500
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/14/2019$630K—Private party → Private party$547/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GREAT WALL CONSULTANT PROFESSIONAL308/04/2020
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SO PLUMBING & HEATING INCPlumbing607/08/2026
MBC CONSTRUCTION CORPGeneral Contractor303/21/2026
INTELOGIC ELECTRIC, INC.Electrical203/22/2026
JEONG YUNGElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GREAT WALL CONSULTANT P.E5633308/04/2020
Building Lifecycle
All (23)Filed (3)Permit Issued (2)Signed Off (2)Violation (6)Special Inspection (10)
01/28/2021
Signed off — Alteration
PROPOSE NEW PLUMBING WORK IN CONJUNCTION WITH A2# 321978918 AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00208521-I1
10/01/2020
Signed off — Alteration
B00210176-I1
08/17/2020
Special inspection requirement — Maintenance information
Xiong Wei Wu
08/17/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiong Wei Wu
08/17/2020
Special inspection requirement — Fire-Resistance Rated Construction
Xiong Wei Wu
08/17/2020
Special inspection requirement — Energy Code Compliance Inspections
Xiong Wei Wu
08/17/2020
Special inspection requirement — Electrical energy consumption
Xiong Wei Wu
08/04/2020
Filed — Alteration
PROPOSE NEW PLUMBING WORK IN CONJUNCTION WITH A2# 321978918 AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00208521-P1
08/03/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
Xiong Wei Wu
08/03/2020
Special inspection requirement — Energy Code Compliance Inspections
Xiong Wei Wu
08/03/2020
Special inspection requirement — Fire-Resistance Rated Construction
Xiong Wei Wu
08/03/2020
Special inspection requirement — Electrical energy consumption
Xiong Wei Wu
08/03/2020
Special inspection requirement — Maintenance information
Xiong Wei Wu
02/19/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/23/2019
Violation issued (ECB, closed)
Construction
10/03/2019
Permit issued — Plumbing
B00208521-I1-PL
09/23/2019
Permit issued — Mechanical Systems
B00210176-I1-MS
09/06/2019
Filed — Alteration
B00210176-I1
08/22/2019
Filed — Alteration
PROPOSE NEW PLUMBING WORK IN CONJUNCTION WITH A2# 321978918 AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00208521-I1
07/12/2019
Violation issued (ECB, closed)
Unknown
07/12/2019
Violation issued (ECB, closed)
Construction
07/12/2019
Violation issued (ECB, closed)
Construction
07/12/2019
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offNICHOLAS SUIDA10/03/2019
DOB NOWMechanical SystemsSigned-offMBC CONSTRUCTION CORP09/23/2019
BISOTISSUEDMBC CONSTRUCTION CORP10/10/2019
1 project · most recent 07/17/2020
General Wiring
FiledStatusContractorScope
07/17/2020CompleteINTELOGIC ELECTRIC, INC.General Wiring
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
08/17/2020Maintenance informationXiong Wei Wuenergy_progress
08/17/2020Fire-Resistant Penetrations and JointsXiong Wei Wuspecial
08/17/2020Fire-Resistance Rated ConstructionXiong Wei Wuprogress
08/17/2020Energy Code Compliance InspectionsXiong Wei Wuprogress
08/17/2020Electrical energy consumptionXiong Wei Wuenergy_progress
08/03/2020Fire-Resistant Penetrations and JointsXiong Wei Wuspecial
08/03/2020Energy Code Compliance InspectionsXiong Wei Wuprogress
08/03/2020Fire-Resistance Rated ConstructionXiong Wei Wuprogress
08/03/2020Electrical energy consumptionXiong Wei Wuenergy_progress
08/03/2020Maintenance informationXiong Wei Wuenergy_progress
▾Documents — 34 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Plumbing2
09/02/2026B00208521-I1Request digital key ↗
08/15/2026B00208521-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/02/2026B00210176-I1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
08/26/2019321978918Open ↗
07/30/2019321978918Open ↗
▸BISWORK PERMIT APPLICATION1
10/10/2019321978918Open ↗
▸Seals & Professional Certifications14
▸DOB NOWProgress Inspector Seal & Signature8
09/22/2026B00208521-P1Open ↗
09/22/2026B00208521-P1Open ↗
09/22/2026B00208521-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026B00208521-P1Open ↗
08/13/2026B00208521-I1Open ↗
08/13/2026B00210176-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/22/2026B00208521-P1Open ↗
08/27/2026B00208521-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
08/28/2019321978918Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/13/2026B00208521-P1Open ↗
08/13/2026B00210176-I1Open ↗
08/13/2026B00208521-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/19/2019321978918Open ↗
▸Energy Compliance3
▸BISAS-BUILT ENERGY ANALYSIS1
10/14/2020321978918Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
10/14/2020321978918Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
08/28/2019321978918Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
10/14/2020321978918Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/14/2020321978918Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
10/14/2020321978918Open ↗
08/19/2019321978918Open ↗
07/30/2019321978918Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
07/30/2019321978918Open ↗
▸BISADDITIONAL INFORMATION1
11/29/2019321978918Open ↗