| Owner | Filings | Most Recent |
|---|---|---|
| 4684 BEDFORD | 22 | 07/15/2026 |
| RELIABLE ENTERPRISES | 14 | 04/09/2026 |
| 3010 BRIGHTON 14TH STREET | 1 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 09/19/2022 | $2.6M | — | — → — | — not available |
| Firm | Filings | Most Recent |
|---|---|---|
| RSLN ARCHITECTURE PLLC | 5 | 07/17/2026 |
| MJE PROFESSIONAL SERVICES | 5 | 10/02/2025 |
| ENGINEERING GROUP ASSOCIATES, PC | 7 | 08/28/2025 |
| STEEL CORE ENGINEERING PLLC | 6 | 05/29/2025 |
| ARYEH SIEGEL ARCHITECT | 1 | 04/28/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| SNR EXPEDITING DESIGN | 10 | 03/21/2026 |
| AVALON DESIGNS | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| BUILD R US CORP | General Contractor | 12 | 07/08/2026 |
| AMOK INC | Fire Protection | 6 | 07/15/2026 |
| RELIABLE ENTERPRISES INC | General Contractor | 3 | 04/09/2026 |
| AMOK INC | Plumbing | 3 | 07/15/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| ENGINEERING PROFESSIONAL | 6393 | 18 | 07/17/2026 |
| STEEL CORE ENGINEERING PL | 1098 | 3 | 05/29/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sprinklers | Permit Issued | AMOK INC | 07/24/2026 |
| DOB NOW | Plumbing | Permit Issued | AMOK INC | 07/14/2026 |
| DOB NOW | Sprinklers | Permit Issued | AMOK INC | 07/14/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | BUILD R US | 09/08/2025 |
| DOB NOW | General Construction | Permit Issued | BUILD R US | 08/12/2025 |
| DOB NOW | Construction Fence | Signed-off | BUILD R US | 08/06/2025 |
| DOB NOW | Plumbing | Permit Issued | AMOK INC | 05/09/2025 |
| DOB NOW | Plumbing | Permit Issued | AMOK INC | 05/09/2025 |
| DOB NOW | Plumbing | Permit Issued | AMOK INC | 05/09/2025 |
| DOB NOW | Protection and Mechanical Methods | Signed-off | RELIABLE ENTERPRISES INC | 03/19/2025 |
| DOB NOW | Supported Scaffold | Signed-off | RELIABLE ENTERPRISES INC | 02/21/2025 |
| DOB NOW | Sidewalk Shed | Signed-off | RELIABLE ENTERPRISES INC | 02/19/2025 |
| DOB NOW | General Construction | Permit Issued | BUILD R US | 12/19/2024 |
| DOB NOW | Construction Fence | Signed-off | BUILD R US | 08/02/2024 |
| DOB NOW | Plumbing | Permit Issued | AMOK INC | 02/28/2024 |
| DOB NOW | Sprinklers | Permit Issued | AMOK INC | 02/28/2024 |
| DOB NOW | Standpipe | Permit Issued | AMOK INC | 02/27/2024 |
| DOB NOW | General Construction | Permit Issued | BUILD R US | 02/23/2024 |
| DOB NOW | Structural | Signed-off | BUILD R US | 02/16/2024 |
| DOB NOW | Foundation | Signed-off | BUILD R US | 02/07/2024 |
| DOB NOW | Support of Excavation | Signed-off | BUILD R US | 02/06/2024 |
| DOB NOW | Construction Fence | Signed-off | BUILD R US | 06/22/2023 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/17/2026 | Permit Issued | BUILD R US CORP | Heating and Air Conditioning Systems | Heat / Cool Daikin RXSQ24TA 24,000 BTU · Vrf Outdoor ×17 RXTQ36TA 36,000 BTU · Vrf Outdoor ×9 RXTQ48TA 48,000 BTU · Vrf Outdoor ×9 RXSQ36TA 36,000 BTU · Vrf Outdoor ×4 RX09NMVJU 9,000 BTU · Heat Pump Outdoor ×3 RXL12WMVJU9 10,600 BTU · Heat Pump Outdoor ×4 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/17/2026 | Permit Issued | AMOK INC | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/17/2026 | Permit Issued | AMOK INC | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/20/2025 | Permit Issued | POWER DIRECT ELECTRIC INC | — |
| 02/18/2025 | Complete | RICHARD NEU | — |
| 12/05/2024 | Permit Issued | MAC ELECT'L CONTR. INC. | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/17/2026 | Permit Issued | AMOK INC | Concrete, Masonry |
| Date | Type | Result | Report |
|---|---|---|---|
| 09/04/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 12/20/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 12/20/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 03/28/2024 | Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments) | Certified | View ↗ |
| 12/18/2023 | Certified StandPipe - SD - Alarm Sys 64/09 - Finish | Certified | View ↗ |
| 12/18/2023 | Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments) | Certified | View ↗ |
| 10/10/2023 | Certified StandPipe - SD - Alarm Sys 64/09 - Finish | Certified | View ↗ |
| 10/10/2023 | Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet) | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 05/07/2026 | Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable) | OLEG RUDITSER | special |
| 05/07/2026 | Insulation placement and R values | OLEG RUDITSER | energy_progress |
| 05/07/2026 | Lighting in dwelling units | OLEG RUDITSER | energy_progress |
| 05/07/2026 | Lighting controls | OLEG RUDITSER | energy_progress |
| 05/07/2026 | Maintenance information | OLEG RUDITSER | energy_progress |
| 05/07/2026 | Electrical motors and elevators | OLEG RUDITSER | energy_progress |
| 05/07/2026 | Exterior lighting power | OLEG RUDITSER | energy_progress |
| 05/07/2026 | Fenestration areas | OLEG RUDITSER | energy_progress |
| 05/07/2026 | Fenestration air leakage | OLEG RUDITSER | energy_progress |
| 05/07/2026 | Air barrier - visual inspection | OLEG RUDITSER | energy_progress |
| 05/07/2026 | Interior lighting power | OLEG RUDITSER | energy_progress |
| 05/07/2026 | Fenestration and door U-factor and product ratings | OLEG RUDITSER | energy_progress |
| 05/07/2026 | Air barrier — testing | OLEG RUDITSER | energy_progress |
| 05/07/2026 | Metering | OLEG RUDITSER | energy_progress |
| 05/07/2026 | Energy Code Compliance Inspections | OLEG RUDITSER | progress |
| 05/07/2026 | Fire-Resistance Rated Construction | OLEG RUDITSER | progress |
| 05/07/2026 | Lowest Floor Elevation | OLEG RUDITSER | progress |
| 05/07/2026 | Combustible Exterior Wall Coverings | OLEG RUDITSER | special |
| 05/07/2026 | Fire-Resistant Penetrations and Joints | OLEG RUDITSER | special |
| 03/24/2026 | Combustible Exterior Wall Coverings | OLEG RUDITSER | special |
| 03/24/2026 | Air barrier — testing | OLEG RUDITSER | energy_progress |
| 03/24/2026 | Exterior lighting power | OLEG RUDITSER | energy_progress |
| 03/24/2026 | Insulation placement and R values | OLEG RUDITSER | energy_progress |
| 03/24/2026 | Electrical motors and elevators | OLEG RUDITSER | energy_progress |
| 03/24/2026 | Air barrier - visual inspection | OLEG RUDITSER | energy_progress |