← Back
BuildNYC
Three families
3024 BOUCK AVENUE
BRONX · Pelham Gardens · BIN 2056055
💬 Discuss this project
2023Year Built
2Stories
C0Building Class
R5Zoning
3,060 sfGross Floor Area
3Units
Rent Stabilized0 Active Violations
Three families · 2,500 sf lot · 1.22 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionCivilGeneralOther
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof5p · 1 filing · 20 docs
Floor 2Wet pipe sprinkler system for 3-family dwelling46p · 2 filings · 20 docs
Floor 1Wet pipe sprinkler system for 3-family dwelling59p · 2 filings · 20 docs
Basement44p · 1 filing · 20 docs
Sub-BasementWet pipe sprinkler system for 3-family dwelling1 filing · 3 docs
Site & exteriorConstruction fence information panel layout40p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
United2607/08/2026
Bouck Builders203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/25/2024$1.2M—BOUCK BUILDERS LLC → Private party$399/sf building
02/23/2022$508K—Private party → BOUCK BUILDERS LLC— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Gerald Caliendo Architects505/24/2023
Sideris Kefalas Engineers112/09/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Gerald J Caliendo Architect P1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Ivan RosaGeneral Contractor903/21/2026
Ivan RosaScaffold707/08/2026
All Pro Plumbing & HeatingPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF Services5616405/24/2023
Building Lifecycle
04/10/2024
Signed off — New Building
FILED HEREWITH PLANS AND APPLICATIONS FOR A THREE (3) STORY, THREE (3) FAMILY SEMI-ATTACHED NEW BUILDING.
X00796622-S1
04/09/2024
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
04/01/2024
Signed off — Alteration
Filing plumbing work type for sprinkler system (with less than 30 heads) as allowed by building code for new 3-family building. Filed in conjunction with NB #X00796622.
X08037396-I1
03/28/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/22/2024
Signed off — New Building
FILED HEREWITH PLANS AND APPLICATIONS FOR A THREE (3) STORY, THREE (3) FAMILY SEMI-ATTACHED NEW BUILDING.
X00796622-S2
74 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutSigned-offIvan Rosa02/09/2024
DOB NOWGeneral ConstructionPermit IssuedIvan Rosa09/14/2023
DOB NOWConstruction FenceSigned-offIvan Rosa09/14/2023
DOB NOWPlumbingSigned-offAll Pro Plumbing & Heating06/19/2023
DOB NOWConstruction FenceSigned-offIvan Rosa05/09/2023
DOB NOWPlumbingSigned-offAll Pro Plumbing & Heating04/21/2023
DOB NOWStructuralPermit IssuedIvan Rosa03/27/2023
DOB NOWConstruction FenceSigned-offIvan Rosa05/11/2022
BIS—ISSUEDIvan Rosa08/11/2022
1 project · most recent 05/24/2023
Heating Systems Ventilation Systems
FiledStatusContractorScope
05/24/2023Signed-offIvan RosaHeating Systems, Ventilation Systems
1 project · most recent 05/24/2023
Gas Storm Water/Sanitary
FiledStatusContractorScope
05/24/2023Signed-offAll Pro Plumbing & HeatingGas, Storm, Water/Sanitary
1 project · most recent 04/04/2024
General Wiring
FiledStatusContractorScope
04/04/2024CompleteRoney ElectricGeneral Wiring
1 project · most recent 05/24/2023
Steel Concrete Wood
FiledStatusContractorScope
05/24/2023Signed-offIvan RosaSteel, Concrete, Wood
1 project · most recent 05/24/2023
Earthwork
FiledStatusContractorScope
05/24/2023Signed-offIvan RosaEarthwork
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
04/09/2024Pass-Final Curb Cut Non-Directive 14PassView ↗
03/28/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/22/2024Pass-Final CND-Occupancy InspectionPassView ↗
03/14/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/13/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/07/2024Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
03/07/2024Fail-Final Curb Cut Non-Directive 14FailView ↗
03/05/2024Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
02/28/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/03/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/12/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
04/14/2023Concrete - Cast-In-PlaceFAHAD FATEHspecial
04/14/2023Excavations - Sheeting, Shoring, and BracingFAHAD FATEHspecial
04/14/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
04/14/2023Heating SystemsFAHAD FATEHspecial
04/14/2023Mechanical SystemsFAHAD FATEHspecial
04/14/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationFAHAD FATEHspecial
04/14/2023Smoke Control Systems TestingFAHAD FATEHspecial
04/14/2023Structural Cold-Formed SteelFAHAD FATEHspecial
04/14/2023Structural Steel - DetailsFAHAD FATEHspecial
04/14/2023Subgrade InspectionsFAHAD FATEHspecial
04/14/2023Subsurface Investigations (Borings/Test Pits)FAHAD FATEHspecial
04/14/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
04/14/2023FinalFAHAD FATEHprogress
04/14/2023Footing and FoundationFAHAD FATEHprogress
04/14/2023HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
04/14/2023Maintenance informationFAHAD FATEHenergy_progress
04/14/2023Air barrier — testing FAHAD FATEHenergy_progress
04/14/2023Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
04/14/2023Insulation placement and R valuesFAHAD FATEHenergy_progress
04/14/2023MeteringFAHAD FATEHenergy_progress
04/14/2023Air barrier - visual inspectionFAHAD FATEHenergy_progress
04/14/2023Fenestration areasFAHAD FATEHenergy_progress
04/14/2023Duct leakage testing, insulation and designFAHAD FATEHenergy_progress
04/14/2023Permanent certificateFAHAD FATEHenergy_progress
04/14/2023Interior lighting powerFAHAD FATEHenergy_progress
Latest 25 of 32.
78 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account