← Back
Predominantly retail with other uses
303 CANAL STREET
MANHATTAN · SoHo-Little Italy-Hudson Square · BIN 1003006
💬 Discuss this project
1808Year Built
3Stories
K4Building Class
M1-5/R9XZoning
—Gross Floor Area
2Units
5 Open Violations 2 unresolved · 3 paperwork only ▸FDNY Report ↗
Predominantly retail with other uses · Owner of record: JAVIN CANAL REALTY, INC. · 3 FAR built · Flood zone X500
Locations of Work
Plumbing
Floor 31p · 1 filing · 13 docs
Floor 22p · 1 filing · 13 docs
Floor 1
Cellar2p · 1 filing · 13 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
METRO CONTRACTING NY503/22/2026
G.M. CONSTRUCTION & WATER203/22/2026
OWNER OF 303 CANAL ST203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PEACHY CONSTRUCTION207/07/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PEACHY CONSTRUCTION203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DEMAR PLUMBING CORPPlumbing307/08/2026
SYED-NAQVI ALTAFElectrical103/21/2026
SYED-NAQVI, ALTAFElectrical103/21/2026
Building Lifecycle
All (50)Filed (2)Permit Issued (3)Violation (42)Special Inspection (3)
06/16/2023
Violation issued (ECB, open)
Zoning
10/27/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/27/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/20/2021
Special inspection requirement — Energy Code Compliance Inspections
JOHN PEACHY
08/20/2021
Special inspection requirement — Final
JOHN PEACHY
08/20/2021
Special inspection requirement — HVAC insulation and sealing
JOHN PEACHY
08/06/2021
Violation issued (ECB, closed)
Construction
07/26/2021
Violation issued (ECB, closed)
Construction
07/26/2021
Violation issued (ECB, closed)
Construction
07/26/2021
Violation issued (ECB, closed)
Construction
07/26/2021
Violation issued (ECB, closed)
Construction
07/26/2021
Violation issued (ECB, closed)
Zoning
07/07/2021
Filed — Alteration
RELOCATION OF EXISTING GAS METER, REPLACEMENT OF GAS PIPING THROUGHOUT BUILDING, INSTALLATION OF NEW GAS HEATERS AND HOT WATER HEATER; NO CHANGE TO USE, OCCUPANCY OR EGRESS. AMENDMENT TO APPLICATION 2/18/20: REMOVE GAS EQUIPMENT THROUGHOUT BUILDING, CAP GAS PIPING AND REMOVE GAS METER IN THE CELLAR.
M00000200-P1
02/07/2020
Permit issued — Plumbing
M00000200-I1-PL
05/16/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/25/2019
Violation issued (ECB, open)
Zoning
02/25/2019
Violation issued (ECB, open)
Construction
09/11/2017
Permit issued — Plumbing
M44895282-I1-PL
08/04/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/05/2017
Violation issued (ECB, closed)
Construction
07/05/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/05/2017
Violation issued (ECB, closed)
Construction
05/19/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/03/2017
Permit issued — Plumbing
M00000200-I1-PL
01/31/2017
Filed — Alteration
RELOCATION OF EXISTING GAS METER, REPLACEMENT OF GAS PIPING THROUGHOUT BUILDING, INSTALLATION OF NEW GAS HEATERS AND HOT WATER HEATER; NO CHANGE TO USE, OCCUPANCY OR EGRESS. AMENDMENT TO APPLICATION 2/18/20: REMOVE GAS EQUIPMENT THROUGHOUT BUILDING, CAP GAS PIPING AND REMOVE GAS METER IN THE CELLAR.
M00000200-I1
01/30/2017
Violation issued (ECB, closed)
Construction
04/26/2016
Violation issued (ECB, closed)
Construction
04/26/2016
Violation issued (ECB, closed)
Construction
04/26/2016
Violation issued (ECB, closed)
Construction
05/07/2013
Violation issued (FDNY_NOV, closed)
05/07/2013
Violation issued (FDNY_NOV, closed)
07/27/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/27/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/27/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/21/2008
Violation issued (ECB, closed)
Zoning
07/17/2008
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/01/2001
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
03/01/2001
Violation issued (ECB, closed)
Construction
06/02/1999
Violation issued (ECB, closed)
Construction
11/03/1997
Violation issued (ECB, closed)
Construction
05/03/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/03/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/03/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/03/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/22/1994
Violation issued (ECB, closed)
Zoning
03/30/1994
Violation issued (ECB, closed)
Construction
01/24/1994
Violation issued (ECB, closed)
Construction
12/17/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/17/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/21/1991
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedDEMAR PLUMBING CORP02/07/2020
DOB NOWPlumbingSigned-offDEMAR PLUMBING CORP09/11/2017
DOB NOWPlumbingPermit IssuedDEMAR PLUMBING CORP02/03/2017
BISPLISSUEDRRP PLUMBING CORP11/20/2018
BISOTISSUEDTSANG CONSTRUCTION, INC04/04/2018
BISPLISSUEDHP SERVICES INC02/01/2018
BISOTISSUEDTSANG CONSTRUCTION, INC11/29/2017
BIS—ISSUEDL.S. SIGN CO., INC02/24/2017
BISMHISSUEDFOREVIEW CONSTRUCTION INC02/06/2017
BISPLISSUEDBARMOR REHAB INC01/23/2017
BISEQISSUEDFOREVIEW CONSTRUCTION INC01/09/2017
BISOTISSUEDFOREVIEW CONSTRUCTION INC01/09/2017
BISEQISSUEDG.M. CONSTRUCTION & WATERPROOF12/30/2016
BISOTISSUEDG.M. CONSTRUCTION & WATERPROOF12/30/2016
BISMHISSUEDG.M. CONSTRUCTION & WATERPROOF12/30/2016
BISPLISSUEDTOP PLUMBING GROUP,INC04/29/2016
BISOTISSUEDG.M. CONSTRUCTION & WATERPROOF03/28/2016
BISOTISSUEDG.M. CONSTRUCTION & WATERPROOF03/03/2016
BISEQISSUEDG.M. CONSTRUCTION & WATERPROOF03/03/2016
BISEQISSUEDMETRO CONTRACTING NY, INC.03/02/2016
BISEQISSUEDSUN SUN CONSTRUCTION INC02/09/1995
BISOTISSUEDSUN SUN CONSTRUCTION INC02/09/1995
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
08/20/2021Energy Code Compliance InspectionsJOHN PEACHYprogress
08/20/2021FinalJOHN PEACHYprogress
08/20/2021HVAC insulation and sealing JOHN PEACHYenergy_progress
▾Documents — 195 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Plumbing2
09/03/2026M00000200-I1Request digital key ↗
08/15/2026M00000200-P1Request digital key ↗
▸DOB NOWPlans/Sketch1
09/03/2026M00000200-I1Request digital key ↗
▸Applications & Permits46
▸BISPLAN / WORK APPROVAL APPLICATION22
09/07/2023121205631Open ↗
02/23/2022121205631Open ↗
09/19/2019123515035Open ↗
Showing 3 of 22 on file for this type
▸BISWORK PERMIT APPLICATION22
11/20/2018123515026Open ↗
04/04/2018122444266Open ↗
04/04/2018122444266Open ↗
Showing 3 of 22 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
01/23/2017140578961Open ↗
▸DOB NOWLPC Approval/Permit1
08/13/2026M00000200-P1Open ↗
▸Seals & Professional Certifications35
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION13
02/28/2019122444266Open ↗
02/28/2019122444266Open ↗
02/28/2019140601953Open ↗
Showing 3 of 13 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT5
03/01/2017122906793Open ↗
02/02/2017140601953Open ↗
11/23/2016140578961Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
11/14/2018123515026Open ↗
11/13/2018123515026Open ↗
03/01/2017122906793Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
02/02/2017140601953Open ↗
11/23/2016140578961Open ↗
02/22/2016140461159Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION3
02/02/2017140601953Open ↗
11/23/2016140578961Open ↗
02/22/2016140461159Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
09/20/2026M00000200-I1Open ↗
09/20/2026M00000200-I1Open ↗
09/20/2026M00000200-I1Open ↗
▸BISProfessional and Owner Certification (POC3)2
11/30/2018123515035Open ↗
11/14/2018123515026Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026M00000200-P1Open ↗
08/13/2026M00000200-I1Open ↗
▸Trade Schedules & Equipment8
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE4
12/03/2018123515026Open ↗
12/03/2018123515026Open ↗
11/14/2018123515026Open ↗
Showing 3 of 4 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT2
02/28/2019140601953Open ↗
02/28/2019140601953Open ↗
▸BISEQUIPMENT USE PERMITS1
02/28/2019140601953Open ↗
▸BISSCHEDULE B - PLUMBING1
11/23/2016140578961Open ↗
▸Safety & Tenant Protection3
▸BISTENANT PROTECTION PLAN AND NOTES1
02/22/2016140461159Open ↗
▸BISSTREET TREE CHECKLIST1
11/30/2018123515035Open ↗
▸DOB NOWTenant Protection Plan1
08/13/2026M00000200-P1Open ↗
▸Environmental & Asbestos8
▸BISASBESTOS: CERTIFICATION (DEP ACP5)6
11/30/2018123515035Open ↗
11/14/2018123515026Open ↗
08/28/2018122444266Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: EXEMPTION (ASB4)1
03/08/2016122524633Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026M00000200-I1Open ↗
▸Energy Compliance20
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS8
02/28/2019122444266Open ↗
02/28/2019140601953Open ↗
02/12/2019123515026Open ↗
Showing 3 of 8 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS5
02/28/2019122444266Open ↗
02/28/2019140601953Open ↗
02/12/2019123515026Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
02/02/2017140601953Open ↗
11/23/2016140578961Open ↗
▸BISNYCECC ANALYSIS2
02/02/2017140601953Open ↗
11/23/2016140578961Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS2
02/02/2017140601953Open ↗
11/23/2016140578961Open ↗
▸DOB NOWHVAC INSULATION AND SEALING (CERTIFICATE/LETTER)1
08/13/2026M00000200-I1Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
02/02/2017140601953Open ↗
11/23/2016140578961Open ↗
02/22/2016140461159Open ↗
▸Approvals, Objections & Sign-offs27
▸BISLANDMARKS APPROVAL13
02/28/2019122444266Open ↗
02/28/2019140601953Open ↗
02/12/2019123515026Open ↗
Showing 3 of 13 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST8
02/28/2019122444266Open ↗
02/28/2019140601953Open ↗
02/28/2019140461159Open ↗
Showing 3 of 8 on file for this type
▸BISSUPERSEDING LETTER2
11/30/2017122444266Open ↗
11/29/2017122444266Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE2
04/25/2019123515035Open ↗
11/30/2018123515035Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
02/28/2019140461159Open ↗
▸DOB NOWLANDMARKS APPROVAL (LPC CERTIFICATE/LETTER)1
08/13/2026M00000200-I1Open ↗
▸Cost, Insurance & Ownership16
▸BISCOST AFFIDAVIT13
02/28/2019122444266Open ↗
02/28/2019140601953Open ↗
02/12/2019123515026Open ↗
Showing 3 of 13 on file for this type
▸BISCIVIL PENALTY AFFADAVIT/REQUEST3
01/09/2017140578961Open ↗
03/02/2016140461159Open ↗
03/02/2016140461159Open ↗
▸Filing & Intake Forms25
▸BISBOROUGH INTAKE FORM12
02/28/2019122444266Open ↗
02/28/2019140601953Open ↗
02/28/2019140461159Open ↗
Showing 3 of 12 on file for this type
▸BISADDITIONAL INFORMATION6
02/26/2019140601953Open ↗
01/28/2019122444266Open ↗
12/03/2018123515026Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING COVER SHEET4
11/30/2018123515035Open ↗
11/14/2018123515026Open ↗
03/01/2017122906793Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET3
02/02/2017140601953Open ↗
11/23/2016140578961Open ↗
02/22/2016140461159Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
11/30/2018123515035Open ↗