HPD05/07/2026(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD11/17/2025§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
HPD06/12/2025(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD04/16/2024(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD03/29/2023(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD03/08/2022(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD04/16/2021(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
DOB10/12/2017FTM BLDG IN SAFE COND.WINDOWS FACING REAR OF BLDG LOC ALONG LINE B OF APTS THERE ARE DIAGONAL CRACKING AT WALL FRAMING WINDOWS FROM BASEMENT TO 4THFL.VERT CRACKS AT WALL FRAMING WINDOW AT UNITS 1B&2B.REMEDY:OWN ENGAGE NYS PROF ENG'R EVAL BLDG&PREP REPAIRS.PERM FOR REPAIRS TO BE OBTAIN NO LATER 11/2/17.SIGN OFF JOB NO LATER 3/5/18
DOB10/10/2017STRUCTURE RENDERED NON-COMPLIANT. AT TIME OF INSPECTION, DAMAGE SUSTAI NED TO APTS 2B &3B DUE TO COLLAPSE CEILINGS PROBABLY CAUSED BY STRU CTURAL PILING BEING DONE OF ADJ PROPERTY 1802 2ND AVE. OCCUPIED APTS 1 B,2B,2C HAVE CRACKS ON CEILINGS & WALLS, SOME CRACKS ARE OLD & PATCHED OTHERS RECURRING & NEW.@ EXP 3 NORTH ELV CRACKS AT WINDOW&THRUOUT BLDG
HPD08/27/2017§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING MATERIAL AT CEILING LOCATED AT APT 1B, 1st STORY
HPD08/27/2017§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 1B, 1st STORY
HPD08/27/2017§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 1B, 1st STORY
HPD08/27/2017§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH EAST AND WEST WALLS APPROX. 20 SQ. FT AT LOWERLEVEL LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD08/27/2017§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF HEAVY DUTY EXTENSION CORD FROM 1ST STORY TO 2ND STORY PUBLIC HALL TO APARTMENT #2B
HPD08/27/2017§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR UNKEYED PLASTER AT NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD08/27/2017§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING LOCATED AT APT 1B, 1st STORY
HPD08/27/2017§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD08/27/2017§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED LOCATED AT APT 1B, 1st STORY
HPD08/21/2017§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 1C, 2nd APARTMENT FROM WEST AT NORTH
HPD08/21/2017§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY
HPD08/21/2017§ 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT CONSISITING OF HORIZONTAL CRACK APPROXIMATELY 0.25 INCH WIDE BY 4 FEET LONG AT WEST WALL FROM NORTH TO SOUTH WALL, AT LOWER LEVEL AT DUPLEX APARTMENT IN THE 1st ROOM FROM NORTH LOCATED AT APT 1C, 2nd APARTMENT FROM WEST AT NORTH
HPD08/21/2017§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD08/21/2017§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH AND EAST WALLS IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD08/21/2017§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD08/21/2017§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY
HPD08/21/2017§ 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT CONSISITING OF HORIZONTAL CRACK APPROXIMATELY 1/2 INCH WIDE AND 10 FT LENGTH AT CEILING FROM NORTH WALL TO SOUTH WALL AT UPPER LEVEL AT DUPLEX APARTMENT IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD08/21/2017§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
HPD08/21/2017§ 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT CONSISITING OF HORIZONTAL 0.25 INCH BY 5 FEET CRACK AT EAST WALL FROM NORTH TO SOUTH WALL, AT LOWER LEVEL AT DUPLEX APARTMENT IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD08/21/2017§ 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT CONSISITING OF VERTICAL CRACK APPROXIMATELY 1/2 INCH WIDE AND 10 FT HEIGHT ON NORTH WALL AT UPPER LEVEL AT DUPLEX APARTMENT IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD06/20/2017§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH AND EAST WALL AT STAIR CASE IN THE PRIVATE HALLWAY LOCATED AT APT 1B UPPER LEVEL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD06/20/2017§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
HPD06/20/2017§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH AT 1ST WINDOW FROM WEST IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B UPPER LEVEL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD06/20/2017§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WOOD DOOR TO REAR YARD IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B LOWER LEVEL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD06/20/2017§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD06/20/2017§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD06/20/2017§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, NORTH AND EAST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B UPPER LEVEL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD06/20/2017§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST AND WEST WALL IN THE 14th ROOM FROM NORTH LOCATED AT APT 1B LOWER LEVEL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD06/20/2017§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF 1/4 INCH GAP FROM WINDOW FRAME TO GLASS PANE AT CENTER STATIONARY WINDOW IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B UPPER LEVEL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD06/20/2017§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH AT 3RD WINDOW FROM WEST IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B UPPER LEVEL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD06/20/2017§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, NORTH, AND SOUTH WALLS IN THE 14th ROOM FROM NORTH LOCATED AT APT 1B LOWER LEVEL, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD06/20/2017§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY
HPD06/20/2017§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY
HPD06/20/2017§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
HPD05/16/2017§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT EAST WALL AND NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD05/16/2017§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD05/16/2017§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE WINDOW FRAME IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD05/16/2017§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY
HPD05/16/2017§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL AND NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD05/16/2017§ 27-2005 ADM CODE REFIT DOORS COMING OFF HINGES IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD05/16/2017§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM SYSTEM LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD05/16/2017§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT BOILER ROOM DOOR AND AT PUBLIC HALL, 1st STORY
HPD09/01/2016SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MASONARY STAIR TREAD 4TH UP AT REAR YARD
HPD09/01/2016SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL IN THE BATHROOM LOCATED AT APT 1C, 1st STORY
HPD09/01/2016SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE HANDRAIL AT STAIRS IN THE PRIVATE HALLWAY LOCATED AT CELLAR APT 1C
HPD09/01/2016SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE
HPD09/01/2016SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES
HPD09/01/2016SECTION 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRES AT CEILING IN THE KITCHEN LOCATED AT CELLAR APT 1C
HPD09/01/2016SECTION 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF DEFECTIVE LIGHT SWITCH AT NORTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT CELLAR APT 1C
HPD09/01/2016SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL CEILING AT CELLAR
HPD09/01/2016SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CERMIC FLOOR TILES IN THE BATHROOM LOCATED AT CELLAR APT 1C
HPD09/01/2016SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER THE WINDOWS IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD09/01/2016SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AT PUBLIC HALL, 1st STORY
HPD09/01/2016SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 1C, 1st STORY
HPD09/01/2016SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING GATE INSTALLED AT WINDOWS IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD09/01/2016SECTION 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASH BASIN IN THE BATHROOM LOCATED AT APT 1C, 1st STORY
HPD09/01/2016SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CENTER WINDOW SASH IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD09/01/2016SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 1C
HPD09/01/2016SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL WALLS AT CELLAR
HPD09/01/2016SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING AT DOOR TO REAR YARD IN THE 3rd ROOM FROM NORTH LOCATED AT CELLAR APT 1C
HPD09/01/2016SECTION 27-2014 ADM CODE PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EXTERIOR WINDOW FRAMES AND SASHES AT NORTH IN THE 3rd ROOM FROM NORTH LOCATED AT CELLAR APT 1C
HPD09/01/2016SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT CELLAR APT 1C
HPD09/01/2016SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM NORTH LOCATED AT CELLAR APT 1C
HPD09/01/2016SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOWS WILL NOT OPEN IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD09/01/2016SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM IN THE FOYER LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD09/01/2016SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT ALL CEILINGS IN THE ENTIRE APARTMENT LOCATED AT APT 1C
HPD11/21/2015§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD11/21/2015SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD11/21/2015SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH
ECB08/02/2017FAILURE TO MAINTAIN IN CODE COMPLIANT MANNER.NOTED: IN APT 1B AND 1C LARGE HORIZONTAL CRACK APPEARS AT CELLAR LEVEL AT PARTY WALL.ALSO (NSTALLED)IN APT. 1 C CRACK APPEARS IN STAIRWELL AT BOOKCASE.REMEDY:REPAIRNothing owed — awaiting certificate of correction