| Owner | Filings | Most Recent |
|---|---|---|
| BNA SERVICES | 3 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 10/29/2020 | $657K | — | Private party → Private party | $279/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| ARNOLD MONTAG ARCHITECT AM/PM DESI | 4 | 04/25/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| AM PM DESIGN CONSULTING P C | 6 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| B36 SERVICES INC | General Contractor | 6 | 03/21/2026 |
| BNA SERVICES INC | General Contractor | 4 | 07/08/2026 |
| JOHN EVAN CONTRACTING COR | General Contractor | 3 | 03/21/2026 |
| MARTIN DORKIN | Electrical | 1 | 03/22/2026 |
| AMC PLBG, HTG & CLNG, INC | Plumbing | 1 | 07/08/2026 |
| PIPESTYLISTS, INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| AFM INSPECTIONS & ENGINEE | 4675 | 2 | 04/22/2022 |
| ARNOLD MONTAG ARCHITECT, | 4599 | 2 | 04/22/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Permit Issued | AMC PLBG, HTG & CLNG, INC | 03/27/2026 |
| DOB NOW | Mechanical Systems | Permit Issued | JOHN EVAN CONTRACTING COR | 04/10/2024 |
| DOB NOW | General Construction | Permit Issued | B36 SERVICES INC | 01/12/2023 |
| DOB NOW | Construction Fence | Permit Issued | B36 SERVICES INC | 01/12/2023 |
| DOB NOW | Plumbing | Permit Issued | T & T PLUMBING INC | 06/21/2022 |
| DOB NOW | Mechanical Systems | Permit Issued | BNA SERVICES INC | 01/14/2022 |
| DOB NOW | Construction Fence | Permit Issued | BNA SERVICES INC | 01/06/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 04/25/2022 | Permit Issued | JOHN EVAN CONTRACTING COR | Air Conditioning Systems, Ventilation Systems | Cooling Mitsubishi Electric MLZ-KP09NA 9,000 BTU · Fan Coil Indoor ×4 MLZ-KP12NA 12,000 BTU · Vrf Indoor ×4 MXZ-8C48NAHZ2-U1 54,000 BTU · Condensing Unit ×2 SEZ-KD18Na 18,000 BTU · Fan Coil Indoor ×2 Ventilation |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/25/2022 | Permit Issued | AMC PLBG, HTG & CLNG, INC | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/06/2022 | Permit Issued | R.C.M. ELECTRIC CORP. | General Wiring |
| 02/11/2022 | Permit Issued | MARTIN DORKIN | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 04/25/2022 | Permit Issued | AMC PLBG, HTG & CLNG, INC | Steel, Concrete, Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 04/16/2026 | No Access-Final PL - Up to 3 Requested Floors | No Access | View ↗ |
| 04/10/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 04/10/2026 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 01/07/2025 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 01/07/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 09/19/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 09/19/2022 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 09/19/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 09/19/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 05/04/2022 | Subgrade Inspections | Anthony Marmo | special |
| 05/04/2022 | Wood – Prefabricated I-Joists | Arnold Montag | special |
| 05/04/2022 | Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable) | MICHAEL KARANTINIDIS, P.E. | special |
| 05/04/2022 | Mechanical Systems | Arnold Montag | special |
| 05/04/2022 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | Arnold Montag | special |
| 05/04/2022 | Structural Steel - Details | Anthony Marmo | special |
| 05/04/2022 | Structural Steel - High Strength Bolting | Anthony Marmo | special |
| 05/04/2022 | Concrete - Cast-In-Place | Anthony Marmo | special |
| 05/04/2022 | Structural Stability – Alterations of existing buildings | Anthony Marmo | special |
| 05/04/2022 | Subsurface Investigations (Borings/Test Pits) | MICHAEL KARANTINIDIS, P.E. | special |
| 05/04/2022 | Structural Steel - Welding | Anthony Marmo | special |
| 05/04/2022 | Fire-Resistant Penetrations and Joints | Arnold Montag | special |
| 05/04/2022 | Structural Wood Frame | Arnold Montag | progress |
| 05/04/2022 | Energy Code Compliance Inspections | Arnold Montag | progress |
| 05/04/2022 | Final | Arnold Montag | progress |
| 05/04/2022 | Fire-Resistance Rated Construction | Arnold Montag | progress |
| 05/04/2022 | HVAC-R and service water piping design and insulation | Arnold Montag | energy_progress |
| 05/04/2022 | Electric vehicle service equipment requirements | Arnold Montag | energy_progress |
| 05/04/2022 | Air barrier — testing | Arnold Montag | energy_progress |
| 05/04/2022 | Fenestration areas | Arnold Montag | energy_progress |
| 05/04/2022 | Fenestration and door U-factor and product ratings | Arnold Montag | energy_progress |
| 05/04/2022 | Ventilation and air distribution system | Arnold Montag | energy_progress |
| 05/04/2022 | Lowest Floor Elevation | MICHAEL KARANTINIDIS, P.E. | progress |
| 05/04/2022 | HVAC-R and service water heating system controls | Arnold Montag | energy_progress |
| 05/04/2022 | Fenestration air leakage | Arnold Montag | energy_progress |