← Back
BuildNYC
Two family converted from one family
3044 TIEMANN AVENUE
BRONX · BIN 2062086
💬 Discuss this project
1920Year Built
1Stories
B3Building Class
R4-1Zoning
1,652 sfGross Floor Area
2Units
Two family converted from one family · 4,750 sf lot · 0.35 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 210p · 1 filing · 20 docs
Floor 18p · 1 filing · 20 docs
Basement11p · 1 filing · 20 docs
Site & exterior12p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Albert Montoya Architect703/25/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Plumbing P & HPlumbing507/08/2026
Mod ConsultantsGeneral Contractor207/08/2026
Ayyub ElectricElectrical103/22/2026
Mod ConsultantsScaffold104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Badaly Architect7137310/23/2025
Building Lifecycle
09/21/2026
Signed off — Alteration CO
remove attic and add 2nd story enlargement to existing 2 family dwelling (co 24476-58).
X01118377-S2
07/17/2026
Signed off — Alteration CO
remove attic and add 2nd story enlargement to existing 2 family dwelling (co 24476-58).
X01118377-S1
07/17/2026
Signed off — Alteration CO
remove attic and add 2nd story enlargement to existing 2 family dwelling (co 24476-58).
X01118377-S3
06/17/2026
Permit expired, never signed off — General Construction
The city's record still shows this permit as issued, with no sign-off on its filing
X01118377-I1-GC
04/17/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
82 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FenceSigned-offMod Consultants06/25/2025
DOB NOWPlumbingSigned-offPlumbing P & H06/23/2025
DOB NOWGeneral ConstructionPermit IssuedMod Consultants06/17/2025
DOB NOWMechanical SystemsSigned-offMod Consultants06/17/2025
BISOTISSUEDAll Technical Art04/03/2006
1 project · most recent 03/25/2026
Gas
FiledStatusContractorScope
03/25/2026Signed-offPlumbing P & HGas
1 project · most recent 02/20/2026
General Wiring
FiledStatusContractorScope
02/20/2026CompleteAyyub ElectricGeneral Wiring
1 project · most recent 03/25/2026
Fence
FiledStatusContractorScope
03/25/2026Signed-offMod ConsultantsFence
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/17/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/01/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/29/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/29/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/29/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 31
DateRequirementInspectorRole
11/07/2025Structural Stability – Alterations of existing buildingsSHAHIN BADALYspecial
11/07/2025Fire-Resistance Rated ConstructionSHAHIN BADALYprogress
11/07/2025Energy Code Compliance InspectionsSHAHIN BADALYprogress
11/07/2025Fire-Resistant Penetrations and JointsSHAHIN BADALYspecial
11/07/2025Air barrier - visual inspectionAlbert Montoyaenergy_progress
11/07/2025Fenestration areasAlbert Montoyaenergy_progress
11/07/2025Fenestration air leakageAlbert Montoyaenergy_progress
11/07/2025Fenestration and door U-factor and product ratingsAlbert Montoyaenergy_progress
11/07/2025Insulation placement and R valuesAlbert Montoyaenergy_progress
11/07/2025Permanent certificateAlbert Montoyaenergy_progress
11/07/2025MeteringAlbert Montoyaenergy_progress
11/07/2025Interior lighting powerAlbert Montoyaenergy_progress
10/20/2025Fire-Resistance Rated ConstructionSHAHIN BADALYprogress
10/20/2025Fire-Resistant Penetrations and JointsSHAHIN BADALYspecial
10/20/2025Structural Stability – Alterations of existing buildingsSHAHIN BADALYspecial
10/20/2025Energy Code Compliance InspectionsSHAHIN BADALYprogress
10/20/2025MeteringAlbert Montoyaenergy_progress
10/20/2025Fenestration and door U-factor and product ratingsAlbert Montoyaenergy_progress
10/20/2025Insulation placement and R valuesAlbert Montoyaenergy_progress
10/20/2025Permanent certificateAlbert Montoyaenergy_progress
10/20/2025Fenestration air leakageAlbert Montoyaenergy_progress
10/20/2025Fenestration areasAlbert Montoyaenergy_progress
10/20/2025Interior lighting powerAlbert Montoyaenergy_progress
10/20/2025Air barrier - visual inspectionAlbert Montoyaenergy_progress
05/20/2025Maintenance informationAlbert Montoyaenergy_progress
Latest 25 of 31.