← Back
Elevator cooperative
Penn South
305 9 AVENUE · BIN 1083604
💬 Discuss this project
1963Year Built
22Stories
D4Building Class
R8Zoning
398,907 sfGross Floor Area
567Units
LL97 CoveredRent Stabilized0 Open ViolationsFISP: SAFE
Elevator cooperative · 84,550 sf lot · 4.72 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PRAT ENTERPRISES707/08/2026
MUT DEVELOPMENT103/22/2026
EMPIRE CONTROL ABATEMENT INC203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HOWARD L ZIMMERMAN ARCH & ENG DPC207/30/2024
ASHRAF CORP103/15/2022
O'BRIEN AND GERE ENGINEERS INC.404/27/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MUNICIPAL BUILDING CONSULTANTS403/21/2026
HOWARD L ZIMMERMAN ARCHITECTS203/21/2026
HLZAE103/21/2026
Rigid Structural Design, LLC103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PRAT ENTERPRISES CORPGeneral Contractor707/08/2026
SAFETECH ELECL CONTNG CORElectrical303/22/2026
FRESH MEADOW MECHANICAL CGeneral Contractor307/08/2026
IPS PLUMBING CORPPlumbing207/08/2026
KEW-FOREST PLBG & HTG INCFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HOWARD L ZIMMERMAN ARCHIT1712207/30/2024
Building Lifecycle
All (113)Filed (7)Permit Issued (8)Signed Off (7)Facade (FISP) (15)Violation (27)Inspection (8)Objection (38)Special Inspection (3)
04/29/2026
Violation issued (HPD, closed)
A
04/08/2025
Signed off — Alteration
Laundry room sprinkler upgrade per plans. No change in use, egress or occupancy.
M01079882-I1
03/04/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/25/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/25/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/19/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/12/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
12/31/2024
Permit issued — Sprinklers
M01079882-I1-EW-SP
09/17/2024
Objection resolved — Addressed
09/17/2024
Objection resolved — Addressed
09/17/2024
Objection resolved — Addressed
09/11/2024
Objection raised — Structural
09/11/2024
Objection raised — Admin
09/11/2024
Objection raised — Scope
07/30/2024
Filed — Alteration
Laundry room sprinkler upgrade per plans. No change in use, egress or occupancy.
M01079882-I1
05/03/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/06/2023
Cycle 9 facade report submitted
10/05/2023
Cycle 9 facade report signed — SAFE
09/20/2023
Signed off — Alteration
FACADE REPAIRS INCLUDING BRICK REPOINTING, CONCRETE EYEBROW REPAIRS, AND REPLACEMENT OF BRICK MASONRY, WINDOW SILLS, LINTELS, TERRA COTTA COPING, AND CONCRETE COPING. NO CHANGE TO USE EGRESS OR OCCUPANCY.
M00714376-I1
08/08/2023
Cycle 9 facade inspection completed
05/03/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/25/2023
Signed off — Alteration
Installation of a temporary sidewalk shed per plan submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M00699044-I1
03/11/2023
Permit issued — Sidewalk Shed
M00699044-I1-SH
09/20/2022
Violation issued (ECB, closed)
Construction
09/09/2022
Violation issued (HPD, closed)
C
09/09/2022
Violation issued (HPD, closed)
C
08/10/2022
Permit issued — General Construction
M00714376-I1-GC
04/29/2022
Filed — Alteration
FACADE REPAIRS INCLUDING BRICK REPOINTING, CONCRETE EYEBROW REPAIRS, AND REPLACEMENT OF BRICK MASONRY, WINDOW SILLS, LINTELS, TERRA COTTA COPING, AND CONCRETE COPING. NO CHANGE TO USE EGRESS OR OCCUPANCY.
M00714376-I1
03/16/2022
Permit issued — Sidewalk Shed
M00699044-I1-SH
03/15/2022
Filed — Alteration
Installation of a temporary sidewalk shed per plan submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M00699044-I1
09/29/2021
Cycle 8 facade report submitted
09/29/2021
Cycle 8 facade report signed — SWARMP
09/27/2021
Signed off — Alteration
EXCAVATION AND SHORING, AND SEALING OF OPENING TO RECEIVED PIPPING AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00501439-I1
09/21/2021
Cycle 8 facade inspection completed
08/20/2021
Signed off — Alteration
INSTALL UNDERGROUND PIPPING FOR HOT & COLD WATER SUPPLY AND RETURN
M00271847-I1
08/20/2021
Signed off — Alteration
INSTALL CONSTRUCTION FENCE AS PER PLANS FILED
M00271919-I1
06/25/2021
Permit issued — General Construction
M00501439-I1-GC
06/11/2021
Signed off — Alteration
REPLACE EXISTING STANDPIPE PIPPING AND POST INDICATOR VALVE AS PER PLANS FILED
M00493949-I1
06/04/2021
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/03/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/27/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/10/2021
Permit issued — Plumbing
M00493949-I1-PL
05/04/2021
Objection raised — Energy
05/04/2021
Objection resolved — Addressed
05/04/2021
Objection raised — Other
05/04/2021
Objection resolved — Addressed
04/27/2021
Filed — Alteration
EXCAVATION AND SHORING, AND SEALING OF OPENING TO RECEIVED PIPPING AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00501439-I1
04/19/2021
Objection raised — Other
04/19/2021
Objection resolved — Addressed
04/19/2021
Objection raised — Other
04/19/2021
Objection resolved — Addressed
04/19/2021
Objection raised — Other
04/19/2021
Objection resolved — Addressed
04/15/2021
Filed — Alteration
REPLACE EXISTING STANDPIPE PIPPING AND POST INDICATOR VALVE AS PER PLANS FILED
M00493949-I1
04/09/2021
Special inspection requirement — Final
CORNELIUS BREEN
02/12/2021
Permit issued — Construction Fence
M00271919-I1-FN
02/11/2021
Permit issued — Plumbing
M00271847-I1-PL
03/18/2020
Objection raised — Inspections
03/18/2020
Objection resolved — Addressed
03/18/2020
Objection raised — Mechanical
Latest 60 of 113 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offKEW FOREST PLBG & HTG INC12/31/2024
DOB NOWSidewalk ShedSigned-offPRAT ENTERPRISES CORP03/11/2023
DOB NOWGeneral ConstructionSigned-offPRAT ENTERPRISES CORP08/10/2022
DOB NOWSidewalk ShedSigned-offPRAT ENTERPRISES CORP03/16/2022
DOB NOWGeneral ConstructionSigned-offFRESH MEADOW MECHANICAL C06/25/2021
DOB NOWPlumbingSigned-offIPS PLUMBING CORP05/10/2021
DOB NOWConstruction FenceSigned-offFRESH MEADOW MECHANICAL C02/12/2021
DOB NOWPlumbingSigned-offIPS PLUMBING CORP02/11/2021
BIS—ISSUEDQUEST BUILDERS GROUP INC03/07/2023
BIS—ISSUEDQUEST BUILDERS GROUP INC12/13/2022
BIS—ISSUEDG-NET CONSTRUCTION CORP10/28/2021
BISPLISSUEDM & S MECHANICAL SVCS INC01/12/2017
BISOTISSUEDF.W. SIMS INC11/09/2015
BISMHISSUEDF.W. SIMS INC11/09/2015
BISOTISSUEDEMPIRE CONTROL ABATEMENT06/10/2015
BISMHISSUEDF.W. SIMS INC05/13/2015
BISOTISSUEDF.W. SIMS INC05/07/2015
BISOTISSUEDMETROPOLITAN PAINTING & C09/11/2014
BISEQISSUEDEMPIRE CONTROL ABATEMENT07/16/2014
BISPLISSUEDP.S.I. MECHANICAL12/14/2012
BISOTISSUEDA&G DESIGN CORPORATION12/11/2012
BISOTISSUEDA&G DESIGN CORPORATION10/25/2012
BISOTISSUEDAM&G WATERPROOFING LLC06/27/2011
BISEQISSUEDS&E BRIDGE & SCAFFOLD LLC.04/12/2011
BIS—ISSUEDNATIVO,LLC10/03/2008
BISEQISSUEDTOWER BUILDING RESTORATION INC.12/13/2001
BISOTISSUEDSKYLINE WINDOWS LLC11/14/1997
BISPLISSUEDNYCO PLBG & HTG CORP10/07/1997
BISMHISSUEDSTEPLIN CONSTRUCTION CORP.09/10/1997
BISEQISSUEDATLANTIC SCAFFOLDING03/28/1996
BISOTISSUEDM & G WATERPROOFING03/12/1996
24 projects · most recent 09/21/2023
General Wiring
FiledStatusContractorScope
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
09/21/2023CompleteSAFETECH ELECL CONTNG COR—
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
03/04/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/25/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/25/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/19/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/12/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/04/2021Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/03/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/27/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
04/09/2021FinalCORNELIUS BREENprogress
11/25/2019HVAC insulation and sealing ROBERT KARPOWICZenergy_progress
11/25/2019FinalROBERT KARPOWICZprogress
▾Documents — 228 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch5
09/02/2026M00699044-I1Request digital key ↗
09/02/2026M00714376-I1Request digital key ↗
08/26/2026M01079882-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Construction Fence1
08/14/2026M00271919-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
08/15/2026M00271847-I1Request digital key ↗
▸Applications & Permits51
▸BISPLAN / WORK APPROVAL APPLICATION27
09/28/2023110197983Open ↗
09/21/2023110197983Open ↗
06/09/2023110197983Open ↗
Showing 3 of 27 on file for this type
▸BISWORK PERMIT APPLICATION20
12/14/2022110197983Open ↗
08/05/2019110197983Open ↗
02/14/2019110197983Open ↗
Showing 3 of 20 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
09/04/2022110197983Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
12/12/2011110197983Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
12/16/2013121416459Open ↗
▸BISOPEN APPLICATIONS SEARCH1
10/03/2023110197983Open ↗
▸Zoning, Tax Lot & Property Records2
▸BISVERIFY TAX LOT1
10/03/2023110197983Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
10/03/2023110197983Open ↗
▸Seals & Professional Certifications50
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION29
02/21/2020123841432Open ↗
09/27/2017122937251Open ↗
05/23/2017122256227Open ↗
Showing 3 of 29 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
09/05/2026M00271919-I1Open ↗
09/05/2026M00271847-I1Open ↗
09/02/2026M00714376-I1Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
05/05/2015122376311Open ↗
05/05/2015122376311Open ↗
07/16/2014140226440Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
08/31/2026M00501439-I1Open ↗
08/26/2026M00271847-I1Open ↗
08/26/2026M00271919-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
05/05/2015122376311Open ↗
04/14/2011120658582Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
07/16/2014140226440Open ↗
10/25/2012140034718Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
07/16/2014140226440Open ↗
10/25/2012140034718Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
04/14/2011120658582Open ↗
▸Trade Schedules & Equipment9
▸BISSELF-CERT PLUMBING NOTICE5
03/26/2013121416459Open ↗
01/23/2013121416459Open ↗
03/12/2009110197983Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE B - PLUMBING3
11/05/2012121416459Open ↗
02/11/2009110197983Open ↗
06/24/2008110197983Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
12/06/2016122937251Open ↗
▸Safety & Tenant Protection6
▸DOB NOWTenant Protection Plan2
08/15/2026M00271847-I1Open ↗
08/14/2026M00271919-I1Open ↗
▸BISTENANT PROTECTION PLAN 2008 CODE1
10/25/2012140034718Open ↗
▸BISSTREET TREE SIGNOFF1
10/03/2023110197983Open ↗
▸BISTenant Protection Plan and Notes1
12/06/2016122937251Open ↗
▸BISST-1: Street Tree Checklist1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos13
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
09/02/2026M00714376-I1Open ↗
08/26/2026M01079882-I1Open ↗
08/13/2026M00501439-I1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
12/06/2016122937251Open ↗
10/25/2012140034718Open ↗
11/05/2012121416459Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
02/01/2011120591332Open ↗
Showing 1 of 2 on file for this type
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
05/05/2015122376311Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
04/14/2011120658582Open ↗
▸BISASBESTOS-EXEMPTION (ASB4)1
01/04/2013120658582Open ↗
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
03/26/2013121512247Open ↗
▸Energy Compliance20
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS11
09/27/2017122937251Open ↗
05/23/2017122256227Open ↗
12/06/2016122937251Open ↗
Showing 3 of 11 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS5
09/27/2017122937251Open ↗
05/23/2017122256227Open ↗
11/24/2015122376311Open ↗
Showing 3 of 5 on file for this type
▸BISTR8: Energy Code Progress Inspections2
03/26/2013121512247Open ↗
11/05/2012121416459Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/25/2012140034718Open ↗
▸BISNYCECC ANALYSIS1
10/25/2012140034718Open ↗
▸Inspections & Test Reports7
▸BISTECHNICAL REPORT: RESPONSIBILITY4
07/21/2022110197983Open ↗
11/17/2021110197983Open ↗
11/17/2021110197983Open ↗
Showing 3 of 4 on file for this type
▸BISMECHANICAL SYSTEMS1
03/17/2023110197983Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
03/17/2023110197983Open ↗
▸BISTECHNICAL REPORT: EXTERIOR WALLS & APPURTS1
11/05/2012121416459Open ↗
▸Approvals, Objections & Sign-offs19
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST9
09/27/2017122937251Open ↗
05/23/2017122256227Open ↗
11/24/2015122376311Open ↗
Showing 3 of 9 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
11/05/2012121416459Open ↗
04/14/2011120658582Open ↗
02/01/2011120591332Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE2
06/09/2023110197983Open ↗
06/24/2008110197983Open ↗
▸BISSUPERSEDING LETTER2
12/14/2022110197983Open ↗
08/05/2019110197983Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
01/03/2013120658582Open ↗
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter1
08/13/2026M01079882-I1Open ↗
▸Cost, Insurance & Ownership21
▸BISCOST AFFIDAVIT20
02/21/2020123841432Open ↗
09/27/2017122937251Open ↗
05/23/2017122256227Open ↗
Showing 3 of 20 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
10/03/2023110197983Open ↗
▸Filing & Intake Forms21
▸BISEFILING COVER SHEET11
02/21/2020123841432Open ↗
12/06/2016122937251Open ↗
05/05/2015122376311Open ↗
Showing 3 of 11 on file for this type
▸BISADDITIONAL INFORMATION5
09/04/2022110197983Open ↗
06/13/2019110197983Open ↗
01/10/2017122937251Open ↗
Showing 3 of 5 on file for this type
▸BISBOROUGH INTAKE FORM3
06/13/2019110197983Open ↗
02/14/2019110197983Open ↗
09/27/2017122937251Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
07/16/2014140226440Open ↗
10/25/2012140034718Open ↗
▸Other Documents2
▸BISPlot Diagram1
06/24/2008110197983Open ↗
▸BISVIOLATIONS SEARCH1
10/03/2023110197983Open ↗