ECB07/21/2026REISSUED#35724670K FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.THE EQUIPMENT ROOM DOOR IS NOT CLOSING PROPER.REM:COMPLY WITH CODE.Nothing owed — awaiting certificate of correction
ECB07/21/2026REISSUED#35724669N FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.CRACKS IN WALLS AT ELECTRICAL ROOM,GYM.REM:COMPLY WITH CODE.Nothing owed — awaiting certificate of correction
ECB07/21/2026REISSUED#35724668L FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.WATER PENETRATION AT CELLAR LEVEL.REM:COMPLY WITH CODE.Nothing owed — awaiting certificate of correction
ECB09/25/2025RE-ISSUE #35682903J. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT ELECTRIC METER ROOM AND AT GYM, THERE VERY OBVIOUS CRACKS IN WALLS. REMEDY: REPAIR/REPLACE.Nothing owed — awaiting certificate of correction
ECB09/25/2025RE-ISSUE #35674846M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: THERE ARE SEVERAL DOORS SCATTERED THROUGHOUT THE SCHOOL THAT ARE NOT OPERATING CORRECTLY. THE DOOR TO THE EQUIPMENT ROOM OUTSIDNothing owed — awaiting certificate of correction
ECB09/25/2025RE-ISSUE #35682904L. FAUILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER. NOTED: AT CELLAR LEVEL, WATER PENETRATION CONTINUES TO ENTRY THROUGH WALLS AND SLAB. REMEDY: REPAIR/REPLACE.Nothing owed — awaiting certificate of correction
ECB08/15/2024REISSUE#35674845K FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.CELLAR LEVEL WATER ENTERS THRU WALLS AND SLAB FROM GROUND.REM:REPAIRAND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB08/15/2024REISSUE#35674848X FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.CELLAR LEVEL ELECTRICAL METER ROOM CRACK IN WALL,ALSO AT GYMNASIUM CRACKS.REM:REPAIR AND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB07/14/2023REISSUE #35658025P. NOTED: AT CELLAR LEVEL BOILER ROOM, AN ACCUMULATION OF WATER ON THE GROUNG, DUE TO WATER PENETRATING THROUGH THE SLAB. OBSERVED TWO SUMP PUMPS IN PLACE IN THOSE AREAS. REPAIR AND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB07/14/2023FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT 4 FLOOR ROOM 46, 2ND FLOOR STAIR C, ROOM 303, 219, 1ST FLOOR ROOM 108, CAFETERIA ENTRANCE BY 133, SMOKE BY EXIT 2, 4, AND MAIN ENTRANCE TO THE BUNothing owed — awaiting certificate of correction
ECB07/14/2023FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT 2ND FLOOR GYMNASIUM AND CELLAR LEVEL ELECTRICAL METER ROOM, BOTH HAS RUNNING CRACKS ON THE WALL IN VARIOUS AREAS THROUGHOUT. REMEDY: REPAIR AND/ONothing owed — awaiting certificate of correction
ECB06/02/2022REISSUE35578321J FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.ATO MY INSP I OBSERVED@CELLAR LEVEL BOILER RM WATER PENETRATING FROM SUMP PIT&FL LEAVING APRX3 OF WATER UNTIL THE BOILER RM,VIO35675321J ISSUED7Nothing owed — awaiting certificate of correction
ECB07/27/2021FAILURE TO PROVIDE POWER FOR EMERGENCY EXIT LIGHTING NOTE:AT TIME OF INSPECTION OBSERVED EMERGENCY LIGHT AXE NOT WORKING AT 1ST FLOOR AND 2ND FLOOR AND ALSO CAFETERIA HALL USE EMERGENCY LIGHT NOT PROPER WORKINGNothing owed — awaiting certificate of correction
ECB07/27/2021REISSUE#35467997H FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTE:DURING INSPECTION OBSERVED AT CELLAR LEVEL/BOILER ROOM WATER ISPENETRATING FROM SUMP PUMP PIT AND FLOOR LEAVING APPROX 3 OF WATER UNINothing owed — awaiting certificate of correction
ECB05/27/2020REISSUE#35434489L FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTE: DURING INSPECTION OBSERVED AT CELLAR LEVEL/BOILER ROOM WATER IS PENETRATING FROM SUMP PUMP PIT & FLOOR LEAVING APPROX 3" OF WATER UNTILNothing owed — awaiting certificate of correction
ECB06/26/2019REISSUE#35331789K FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT TIME OF INSPECTION I OBSERVED AT CELLAR LEVEL AT BOILER ROOM WATER PENETRATION FROM SLAB ON FLOOR,NEED TO BE WATER PROOF FOUNDATIONNothing owed — awaiting certificate of correction
ECB05/29/2018REISSUE # 35216752N FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER IN BOILER ROOM AT CELLAR WATER PENETRATION AT FLOOR AND BOILER PIT. REMEDY: REPAIR AND OR REPLACE.Nothing owed — awaiting certificate of correction
ECB06/07/2017REISSUE# 35216752N. FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTED: IN BOILER ROOM @ CELLAR, WATER PENETRATING FLOOR @ BOILER PIT. REM: REPAIR &/OR REPLACE CONDITION NOTED.Nothing owed — awaiting certificate of correction
ECB11/01/2016FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. REISSUE VIO# 35094816K & 35128514H. NOTED: @ BOILER PIT WATER PENETRATING FLR SLAB. REM: MAINTAIN WATER PROOF INTEGRITY OF FLOOR SLAB/ COMPLY W/ THIS NOV.Nothing owed — awaiting certificate of correction
ECB05/12/2015REISSUE NOV#35094816K FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.@ BOILER PIT WATER PENETRATING FLOOR SLAB.COMPLY W/ NOTICE OF VIO.REM MAINTAIN WATER PROOF INTEGRITY OF FLOOR SLAB.Nothing owed — awaiting certificate of correction
ECB05/20/2014WATER PENETRATION. AT BOILER PIT, THE FOUNDATION HAS BECOME POROUS ALLOWING WATER TO ENTER WITH A 2ND SUMP PUMP ADDED TO CONSTANTLY DRAIN WATER -NOTED DRY DAY. REMEDY: WATER PROOF FOUNDATION.Nothing owed — awaiting certificate of correction
Public elementary, junior or senior high · Owner of record: NYC DEPARTMENT OF PARKS AND RECREATION · 83,263 sf lot · 1.1 FAR built · Flood zone X500