← Back
Walk-up apt, over six families with stores
305 EAST 84 STREET
MANHATTAN · Upper East Side-Yorkville · BIN 1049955
💬 Discuss this project
1915Year Built
5Stories
C7Building Class
R8BZoning
10,160 sfGross Floor Area
20Units
Rent Stabilized11 Open Violations ▸
Walk-up apt, over six families with stores · Owner of record: 305-7 EAST 84TH ASSOCIATES, LLC · 2,554 sf lot · 3.98 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 46p · 1 filing · 13 docs
Floor 3
Floor 2
Floor 11p · 1 filing · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GENERAL PROPERTY MANAGEMENT707/08/2026
305-307 E 84 ST REALTY203/21/2026
305-7 EAST 84TH ASSOCIATES, LLC103/22/2026
EVERGREEN CONSTRUCTION SOLUTIONS IN103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ATELIER XIA DONG105/02/2026
GEE2000 ARCHITECT P.C.305/22/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EVERGREEN CONSTRUCTION SOGeneral Contractor303/21/2026
A.C. MORGAN ELECTRICElectrical103/22/2026
NEW WORLD EURO CONSTRUCTIGeneral Contractor107/08/2026
IMPACT PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ATELIER XIA DONG ARCHITEC8523105/02/2026
SD TESTING & INSPECTION S7010105/02/2026
GEE2000 ARCHITECT P.C.691211/04/2023
Building Lifecycle
All (86)Filed (4)Permit Issued (3)Signed Off (3)Violation (60)Inspection (3)Special Inspection (13)
07/09/2026
Signed off — Alteration
ALTERATION GENERAL CONSTRUCTION WORK FOR A SALON IN AN EXISTING COMMERCIAL TENANT SPACE.NO CHANGE IN USE, OCCUPANCY OR EGRESS.
M01387476-I1
05/21/2026
Permit issued — General Construction
M01387476-I1-GC
05/02/2026
Filed — Alteration
ALTERATION GENERAL CONSTRUCTION WORK FOR A SALON IN AN EXISTING COMMERCIAL TENANT SPACE.NO CHANGE IN USE, OCCUPANCY OR EGRESS.
M01387476-I1
04/19/2026
Special inspection requirement — Lighting controls
Yao Dong
04/19/2026
Special inspection requirement — Interior lighting power
Yao Dong
04/19/2026
Special inspection requirement — Energy Code Compliance Inspections
Yao Dong
04/19/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Yao Dong
04/15/2026
Special inspection requirement — Tenant Protection Plan Compliance
XIUCHENG LI
04/15/2026
Special inspection requirement — Final
Yao Dong
10/14/2025
Violation issued (HPD, open)
C
10/07/2025
Violation issued (ECB, closed)
Construction
10/07/2025
Violation issued (ECB, closed)
Plumbing
09/01/2025
Violation issued (HPD, closed)
C
07/22/2025
Violation issued (ECB, closed)
Construction
07/22/2025
Violation issued (ECB, closed)
Unknown
10/30/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/20/2024
Violation issued (ECB, closed)
Construction
06/07/2024
Signed off — Alteration
Interior Renovation of Unit 4FW on 4th Floor, partition work as per plan, no change in use, occupancy or exit. Plumbing work will be filed subsequently.
M00911466-I1
06/07/2024
Signed off — Alteration
Interior Renovation of Unit 4FW on 4th Floor, partition work as per plan, no change in use, occupancy or exit. Plumbing work will be filed subsequently.
M00911466-S1
05/24/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/24/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/22/2024
Filed — Alteration
Interior Renovation of Unit 4FW on 4th Floor, partition work as per plan, no change in use, occupancy or exit. Plumbing work will be filed subsequently.
M00911466-P1
05/22/2024
Special inspection requirement — Tenant Protection Plan Compliance
PETER GEE
01/26/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/05/2023
Permit issued — Plumbing
M00911466-S1-PL
11/13/2023
Permit issued — General Construction
M00911466-I1-GC
11/04/2023
Filed — Alteration
Interior Renovation of Unit 4FW on 4th Floor, partition work as per plan, no change in use, occupancy or exit. Plumbing work will be filed subsequently.
M00911466-S1
10/16/2023
Filed — Alteration
Interior Renovation of Unit 4FW on 4th Floor, partition work as per plan, no change in use, occupancy or exit. Plumbing work will be filed subsequently.
M00911466-I1
07/31/2023
Special inspection requirement — Lighting in dwelling units
PETER GEE
07/28/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
PETER GEE
07/28/2023
Special inspection requirement — Final
PETER GEE
07/28/2023
Special inspection requirement — Fire-Resistance Rated Construction
PETER GEE
07/28/2023
Special inspection requirement — Energy Code Compliance Inspections
PETER GEE
07/28/2023
Special inspection requirement — Tenant Protection Plan Compliance
PETER GEE
05/26/2023
Violation issued (HPD, open)
B
05/26/2023
Violation issued (HPD, open)
B
05/26/2023
Violation issued (HPD, open)
C
05/26/2023
Violation issued (HPD, closed)
C
05/04/2023
Violation issued (HPD, open)
A
05/04/2023
Violation issued (HPD, closed)
C
05/04/2023
Violation issued (HPD, closed)
B
04/27/2023
Violation issued (HPD, closed)
C
04/27/2023
Violation issued (HPD, closed)
B
04/27/2023
Violation issued (HPD, closed)
B
04/27/2023
Violation issued (HPD, closed)
B
04/27/2023
Violation issued (HPD, closed)
B
04/27/2023
Violation issued (HPD, closed)
C
04/27/2023
Violation issued (HPD, closed)
B
02/24/2023
Violation issued (HPD, open)
B
02/24/2023
Violation issued (HPD, closed)
A
02/24/2023
Violation issued (HPD, open)
B
07/16/2022
Violation issued (HPD, open)
B
07/16/2022
Violation issued (HPD, closed)
C
05/08/2022
Violation issued (HPD, closed)
B
05/08/2022
Violation issued (HPD, closed)
A
05/08/2022
Violation issued (HPD, closed)
B
05/08/2022
Violation issued (HPD, closed)
B
05/08/2022
Violation issued (HPD, closed)
B
05/08/2022
Violation issued (HPD, closed)
B
05/08/2022
Violation issued (HPD, closed)
B
Latest 60 of 86 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offNEW WORLD EURO CONSTRUCTI05/21/2026
DOB NOWPlumbingSigned-offIMPACT PLUMBING INC12/05/2023
DOB NOWGeneral ConstructionSigned-offEVERGREEN CONSTRUCTION SO11/13/2023
BISFBISSUEDNEW YORK HEATING CORP08/08/2013
BISPLISSUEDNEW YORK HEATING CORP08/08/2013
BISPLISSUEDZEFI PLBG AND HTG06/18/2001
BISEQRE-ISSUEDYORK SCAFFOLD EQUIPMENT CORP.09/12/2000
BISOTISSUEDH & L PAINTING & DECORATING INC07/28/2000
BISFSISSUEDROCKWAY FUEL OIL CORP.09/21/1993
2 projects · most recent 04/13/2026
FiledStatusContractorScope
04/13/2026CompleteMAC ELECT'L CONTR. INC.21 meters
04/13/2025Permit IssuedA.C. MORGAN ELECTRIC18 meters, 18 new_meters
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
05/24/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/24/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/26/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
04/19/2026Lighting controlsYao Dongenergy_progress
04/19/2026Interior lighting powerYao Dongenergy_progress
04/19/2026Energy Code Compliance InspectionsYao Dongprogress
04/19/2026Fire-Resistant Penetrations and JointsYao Dongspecial
04/15/2026Tenant Protection Plan ComplianceXIUCHENG LIspecial
04/15/2026FinalYao Dongprogress
05/22/2024Tenant Protection Plan CompliancePETER GEEspecial
07/31/2023Lighting in dwelling unitsPETER GEEenergy_progress
07/28/2023Fire-Resistant Penetrations and JointsPETER GEEspecial
07/28/2023FinalPETER GEEprogress
07/28/2023Fire-Resistance Rated ConstructionPETER GEEprogress
07/28/2023Energy Code Compliance InspectionsPETER GEEprogress
07/28/2023Tenant Protection Plan CompliancePETER GEEspecial
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
09/06/2026M01387476-I1Request digital key ↗
08/28/2026M00911466-I1Request digital key ↗
08/28/2026M00911466-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
08/08/2013140100469Open ↗
08/08/2013140100469Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
08/08/2013140100469Open ↗
▸Seals & Professional Certifications15
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/06/2026M01387476-I1Open ↗
08/13/2026M00911466-S1Open ↗
08/13/2026M00911466-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/21/2026M00911466-I1Open ↗
09/21/2026M00911466-I1Open ↗
08/29/2026M01387476-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/21/2026M00911466-I1Open ↗
08/29/2026M01387476-I1Open ↗
08/29/2026M01387476-I1Open ↗
Showing 3 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
08/08/2013140100469Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
08/08/2013140100469Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
08/08/2013140100469Open ↗
▸Trade Schedules & Equipment4
▸BISSELF-CERT PLUMBING NOTICE2
04/21/2014140100469Open ↗
12/31/2013140100469Open ↗
▸BISSCHEDULE B - PLUMBING1
08/08/2013140100469Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
08/08/2013140100469Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
09/06/2026M01387476-I1Open ↗
08/13/2026M00911466-I1Open ↗
08/13/2026M00911466-P1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
08/08/2013140100469Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
08/08/2013140100469Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
08/08/2013140100469Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
08/08/2013140100469Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
08/08/2013140100469Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
04/15/2014140100469Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
08/08/2013140100469Open ↗