ECB12/22/2025AT THE TIME OF MY INSPECTION, I OBSERVED FACADE COLLAPSE AT EXPOSURE #2 AND DEMOLITION STARTED AT THE 3RD FLOOR FACADE. INVESTIGATION REVEAL THAT THE COMMISSIONER ORDER WAS TO PROVIDE SHORING FROM THE CELLAR TO$12K due
DOB12/09/2025IMMEDIATELY INSTALL 2 LINES OF TEMPORARY SHORING ALONG EXPOSURE 2, FROM CELLAR UP UNDERSIDE OF ROOF, EXTENDING THE FULL LENGTH OF THE BUILDING FROM FRONT TO BACK. INSTALL TRANSVERSE CROSS BRACING BETWEEN THE 2 LINES OF SHORING. AFTER SHORING IS INSTALLED, PARTIALLY
DOB12/08/2025EMERGENCY WORK ORDER.ON/AROUND 11/28/25,EXP2,8INCH BEARNG APPRX 15 LF CLLPSD ONTO ADJ 303 ROOF.REMAINING EXP2 WALL CRCKD&SEVERELY BULGNG OUT &AT RISK OF CLLPSE.EXP2 RUBBLE FDN WALL PRTLLY.OWNR TO IMMED RETAIN NYSPE&GC ENDRSD FOR DEMO TO 1.PE TO PRVDE MEANS&METHDS TO DOB-FEU FOR REVIEW&APPRVL
DOB12/04/2025EMERGENCY WORK ORDER.ON/AROUND 11/28/25 EXP2 WALL@2ND FLOOR PARTIALLY CLLPSD ONTO ADJ 303 VAM BUREN ROOF.035 EXP2 WALL@RISK OF FURTHER CLLPSE.ROOF&BLDG STRCTRLLY CMPRMSD&POSES DNGR TO THE PUBLIC IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER 350221 (112825FEU30301PN) DATED 11/28/2025
ECB11/28/2025FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AS NOTED: AT TIME OF INSPECTION OBSERVED BRICK WALL AT EXP #2 THAT HAS COLLAPSED ONTOTHE ADJ. PROPERTIES ROOF. FAILED TO MAINTAIN BUILDING IN CODE-COMPLIAN$12K due
DOB11/28/2025FAILURE TO MAINTAIN BUILDIING IN CODE COMPLIANT MANNER . AT TIME OF IN SPECTION OBSERVED AT EXPOSURE #2 WALL PARTIAL BRICK WALL COLLAPSE WITH REMAINING SECTIONS LLOSE AND READY TO FALL AFFECTING BUILDING STRUCTU RAL STABILITY : REMEDY SUBMIT ENGINEERS REPORT EVALUATING CITED CONDIT ONS WITH PHOTOS, TIME FRAME FOR REPAIRS TO ERTINSPECTIONS@BUILDINGS.NY
DOB11/28/2025EMERGENCY WORK ORDER.ON/AROUND 11/28/25 EXP2 WALL@2ND FLOOR PARTIALLY CLLPSD ONTO AD 303 VAN BUREN ROOF.305 EXP2 WALL@RISK OF FRTHR CLLPSE ROOF&BLDG STRCTRLLY CMPRMSD&POSES DNGR TO THE PUBLIC.IMMEDIATELY COMPLY COMMISSIONER'S ORDER 350221 (112825FEU30301PN) DATED 11/28/2025
DOB11/28/2025FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.ON/AROUND 11/28/25.APPRX 1FT,&AT RISK OF COLLAPSE.ROOF UNSUPPORTED/INADEQUATELY SUPPORTED EXTENT OF EXP2 WALL INSTABILITY@LOWER FLOORS.OWNR TO RTAIN NYSPE TO EVAL ENT BLDG&FILE RPAIR DWGS.BLDG TO BE PERM RPAIRD UNDR PRMT STRTNG BY 1/19/26&CMPLTD/SGND OFF BY 3/6/25
HPD10/10/2005SECTION 27-2005, 2007 ADMIN. CODE: REMOVE ALL ENCUMBRANCES CONSISTING OF REFRIGERATOR 1ST STY PUBLIC HALL.
HPD10/10/2005SECTION 27-2014 ADMIN. CODE AND DEPARTMENT RULES AND REGULATIONS: SCRAPE AND REMOVE RUST SCALES AND PAINT WITH TWO COATS OF PAINT THE REAR FIRE ESCAPE -ALL STYS.
HPD10/10/2005SECTION 27-2032, 2034 ADNIM. CODE: DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM AT- FRONT AND REAR ROOMS- 2ND STY. APT.
HPD10/10/2005SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE DOOR SADDLE STREET ENTRANCE TO PUBLIC VESTIBULE.
HPD10/10/2005SECTION 27-2005, 2007 ADMIN. CODE: REMOVE ALL ENCUMBRANCES CONSISTING OF WARDROBE & SPACE HEATER 2ND STY PUBLIC HALL.
HPD10/10/2005SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING GLASS SKYLIGHT ABOVE BATHROOM ROOF REAR.
HPD10/10/2005SECTION 27-2005 ADMIN. CODE: FIRE ESCAPE DEFECTIVE. FILL IN HOLES IN WALL AROUND BRACKETS AND/OR RAILS
HPD10/10/2005SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE BRICKWORK AREA AT 3RD STY SOUTH WINDOW BUILDING FRONT.
Two family converted from one family · 1,700 sf lot · 1.35 FAR built · Flood zone X