← Back
Miscellaneous two family
3052 FULTON STREET
BROOKLYN · BIN 3088121
💬 Discuss this project
1920Year Built
3Stories
B9Building Class
R6AZoning
3,000 sfGross Floor Area
2Units
22 Open Violations 18 unresolved · 4 paperwork only ▸FDNY Report ↗
Miscellaneous two family · Owner of record: 3052 FULTON STREET LLC · 2,013 sf lot · 1.49 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanical
Permit Issued — active, not yet Signed-off
RoofUnder Construction8p · 2 filings · 7 docs
Floor 3Under Construction21p · 4 filings · 17 docs
Floor 2Under Construction15p · 4 filings · 16 docs
Floor 1Under Construction15p · 4 filings · 16 docs
CellarUnder Construction14p · 3 filings · 13 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC EXPEDITING CONSULTANTS INC503/22/2026
3052 FULTON STREET LLC103/22/2026
3052 FULTON ST BROOKLYN L303/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/14/2024$800K—— → —$267/sf building
03/01/2023$675K—— → —$225/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PRAMODRAY SHAH, P.E.702/17/2026
SHAHRISH SHUVO ENGINEERING P.C.211/26/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
M W EXPEDITING1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SAPPHIRE CONSTRUCTION GR*General Contractor303/21/2026
YAFE MEOD CORPGeneral Contractor204/09/2026
KISHAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SHAHRISH SHUVO ENGINEERIN8524212/23/2025
Building Lifecycle
All (50)Filed (8)Permit Issued (4)Violation (26)Inspection (3)Objection (9)
03/19/2026
Permit issued — Structural
B01339448-I1-ST
03/03/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/03/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/17/2026
Filed — Alteration
Plumbing work being filed in conjunction with Alt 2 B01200069-I1. No change to use, egress or occupancy.
B01182021-P1
01/30/2026
Violation issued (ECB, open)
Construction
01/08/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/26/2025
Permit issued — General Construction
B01200069-I1-GC
12/23/2025
Filed — Alteration
Structural work being filed in conjunction with Alt 2 Job number B01200069-I1. No change to use, egress or occupancy.
B01339448-I1
12/18/2025
Objection resolved — Addressed
12/01/2025
Permit issued — Plumbing
B01182021-I1-PL
11/19/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
07/24/2025
Objection raised — Zoning
07/24/2025
Objection raised — Cost
07/24/2025
Objection raised — Admin
07/24/2025
Objection raised — Zoning
07/24/2025
Objection raised — Other
07/19/2025
Filed — Alteration
Plumbing work being filed in conjunction with Alt 2 B01200069-I1. No change to use, egress or occupancy.
B01182021-I1
07/19/2025
Filed — Alteration
REPLACE EXISTING BOILER FOR HOT WATER RADIANT HEATING AND NEW HVAC SPLIT SYSTEM. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B01182020-I1
07/18/2025
Filed — Alteration
Interior renovation of Existing 3 Story Mixed use building with Cellar
B01200069-P1
07/18/2025
Filed — Alteration
Structural work being filed in conjunction with Alt 2 Job number B01200069-I1. No change to use, egress or occupancy.
B01182018-I1
04/03/2025
Permit issued — Structural
B01146266-I1-ST
03/25/2025
Filed — Alteration
Interior renovation of Existing 3 Story Mixed use building with Cellar
B01200069-I1
11/26/2024
Filed — Alteration
Temporary Shoring Installation to stabilize the building
B01146266-I1
10/09/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/16/2024
Violation issued (ECB, closed)
Construction
12/27/2023
Violation issued (ECB, open)
Construction
12/21/2023
Violation issued (ECB, open)
Construction
05/05/2023
Violation issued (ECB, closed)
Construction
05/05/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/13/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/13/2023
Violation issued (ECB, closed)
Construction
12/10/2008
Violation issued (ECB, open)
Unknown
06/27/2008
Violation issued (ECB, open)
Unknown
02/27/2008
Violation issued (ECB, closed)
Construction
10/14/2004
Violation issued (HPD, open)
A
10/14/2004
Violation issued (HPD, open)
B
10/14/2004
Violation issued (HPD, open)
B
10/14/2004
Violation issued (HPD, open)
B
10/14/2004
Violation issued (HPD, open)
B
10/14/2004
Violation issued (HPD, open)
A
10/14/2004
Violation issued (HPD, open)
A
10/14/2004
Violation issued (HPD, open)
B
10/14/2004
Violation issued (HPD, open)
B
10/14/2004
Violation issued (HPD, open)
B
10/14/2004
Violation issued (HPD, open)
B
10/14/2004
Violation issued (HPD, open)
A
10/14/2004
Violation issued (HPD, open)
A
08/16/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedYAFE MEOD CORP03/19/2026
DOB NOWGeneral ConstructionPermit IssuedYAFE MEOD CORP12/26/2025
DOB NOWPlumbingSigned-offN AND S PLUMBING INC12/01/2025
DOB NOWStructuralPermit IssuedSAPPHIRE CONSTRUCTION GR*04/03/2025
BISOTISSUEDOWNER04/15/2010
1 project · most recent 07/19/2025
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/19/2025——Air Conditioning Systems
Cooling
Fujitsu ×16
1 project · most recent 12/17/2025
General Wiring
FiledStatusContractorScope
12/17/2025Permit IssuedBRIGHT LIGHT ELECTRICAL CGeneral Wiring
3 projects · most recent 12/23/2025
Wood
FiledStatusContractorScope
12/23/2025Permit IssuedYAFE MEOD CORPWood
07/18/2025——Wood
11/26/2024Permit IssuedSAPPHIRE CONSTRUCTION GR*1 scope_items
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
03/03/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/03/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/08/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
07/21/2025FinalPRAMODRAY SHAHprogress
07/18/2025Wood – Prefabricated I-Joists—special
07/18/2025Wood – Seismic Resistance—special
02/16/2025Structural Stability – Alterations of existing buildings—special
02/16/2025Final—progress
02/16/2025Mechanical Systems—special
02/16/2025Energy Code Compliance Inspections—progress
02/16/2025Final—progress
02/16/2025HVAC-R and service water piping design and insulation—energy_progress
02/16/2025HVAC-R and service water heating equipment—energy_progress
02/16/2025Maintenance information—energy_progress
02/16/2025HVAC-R and service water heating system controls—energy_progress
02/14/2025Fire-Resistant Penetrations and Joints—special
02/14/2025Structural Stability – Alterations of existing buildings—special
02/14/2025Energy Code Compliance Inspections—progress
02/14/2025Fire-Resistance Rated Construction—progress
02/14/2025Exterior lighting power—energy_progress
02/14/2025Fenestration and door U-factor and product ratings—energy_progress
02/14/2025Air barrier — testing —energy_progress
02/14/2025Insulation placement and R values—energy_progress
02/14/2025Fenestration air leakage—energy_progress
02/14/2025Fenestration areas—energy_progress
02/14/2025Air barrier - visual inspection—energy_progress
02/14/2025Lighting controls—energy_progress
02/14/2025Interior lighting power—energy_progress
Latest 25 of 26.
▾Documents — 36 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/23/2026B01146266-I1Request digital key ↗
08/21/2026B01182018-I1Request digital key ↗
08/21/2026B01200069-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits2
▸BISWORK PERMIT APPLICATION1
04/15/2010320015844Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
05/14/2009320015844Open ↗
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/21/2026B01182018-I1Open ↗
08/21/2026B01200069-I1Open ↗
08/21/2026B01200069-P1Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
07/13/2010320015844Open ↗
04/15/2010320015844Open ↗
05/14/2009320015844Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/24/2026B01200069-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/21/2026B01182018-I1Open ↗
08/21/2026B01200069-I1Open ↗
08/21/2026B01200069-P1Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
05/14/2009320015844Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
07/13/2010320015844Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
05/14/2009320015844Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
07/13/2010320015844Open ↗
05/14/2009320015844Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
05/14/2009320015844Open ↗