← Back
Zoned residential, not Manhattan
3073 VILLA AVENUE
BRONX · BIN 2017638
💬 Discuss this project
0Year Built
—Stories
V0Building Class
R8Zoning
0 sfGross Floor Area
0Units
Rent Stabilized29 Open Violations 26 unresolved · 3 paperwork only ▸
Zoned residential, not Manhattan · Owner of record: 3073 VILLA LLC · 2,500 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionEquipmentCivil
Permit Issued — active, not yet Signed-off
RoofUnder Construction68p · 8 filings · 20 docs
Bulkhead1p · 1 filing · 3 docs
Floor 16Under Construction62p · 4 filings · 20 docs
Floor 15Under Construction61p · 4 filings · 20 docs
Floor 14Under Construction61p · 4 filings · 20 docs
Floor 13Under Construction61p · 4 filings · 20 docs
Floor 12Under Construction61p · 4 filings · 20 docs
Floor 11Under Construction61p · 4 filings · 20 docs
Floor 10Under Construction62p · 4 filings · 20 docs
Floor 9Under Construction64p · 4 filings · 20 docs
Floor 8Under Construction143p · 5 filings · 20 docs
Floor 7Under Construction143p · 5 filings · 20 docs
Floor 6Under Construction145p · 6 filings · 20 docs
Floor 5Under Construction143p · 5 filings · 20 docs
Floor 4Under Construction143p · 5 filings · 20 docs
Floor 3Under Construction143p · 5 filings · 20 docs
Floor 2Under Construction145p · 6 filings · 20 docs
Floor 1Under Construction147p · 6 filings · 20 docs
CellarUnder Construction10p · 4 filings · 17 docs
BasementUnder Construction87p · 2 filings · 20 docs
Sub-BasementUnder Construction61p · 5 filings · 20 docs
1 job · most recent 12/02/2025
Heating and Air Conditioning Systems Others Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
12/02/2025Permit IssuedSELCA CONSTRUCTION INCHeating and Air Conditioning Systems, Others, Ventilation Systems
Heat / Cool
Islandaire Islandaire EZGS12K4P1S46AL 1 tons · Ptac ×120
Renewaire RHD10240-10 10 kW · Electric Heater ×120
Lg KNSAE121A 1 tons · Split System ×2
KUSAE121A 1 tons · Heat Pump Outdoor ×2
Ventilation
Renewaire HE-2XJRTH-S15UU-DVNT-L 1,050 CFM · Erv ×120
Indeeco INDEECO 934IW-D1512-W 15 kW · Electric Heater ×8
Other
Greenheck SQ-7-VG 500 CFM · Exhaust Fan ×120
CUBE-220HP-30 4,000 CFM · Exhaust Fan ×2
CUE-100HP-VG 800 CFM · Exhaust Fan ×2
USF-6, USF-12 1,000 CFM ×2
1 job · most recent 08/17/2026
FiledStatusContractorScope
08/17/2026Permit IssuedPRIME PIPING & HEATING IN1,262 heads, 38 outlets
1 job · most recent 08/17/2026
FiledStatusContractorScope
08/17/2026———
6 jobs · most recent 08/26/2026
General Wiring
FiledStatusContractorScope
08/26/2026CompleteFUSED ELECTRIC CONTNG CORGeneral Wiring
08/13/2026CompleteFUSED ELECTRIC CONTNG CORGeneral Wiring
05/04/2026CompleteSOLAS ELECTRICAL CORP—
11/04/2025CompleteSOLAS ELECTRICAL CORP—
09/27/2025CancelledFUSED ELECTRIC CONTNG CORGeneral Wiring
07/08/2022CompleteHIGH QUALITY ELECTRIC OF—
5 jobs · most recent 08/27/2025
Concrete Masonry
FiledStatusContractorScope
08/27/2025Permit IssuedSELCA CONSTRUCTION INC1 scope_items
08/27/2025Permit IssuedSELCA CONSTRUCTION INCConcrete, Masonry
08/26/2025Permit IssuedSELCA CONSTRUCTION INC2 scope_items
08/09/2022——Concrete, Masonry
04/27/2022——1 scope_items
3 jobs · most recent 07/14/2026
Fence Scaffold Sidewalk Shed
FiledStatusContractorScope
07/14/2026Permit IssuedSELCA CONSTRUCTION INCFence
12/19/2025Signed-offCORE SCAFFOLD SYSTEMS INCScaffold
12/12/2025Signed-offCORE SCAFFOLD SYSTEMS INCSidewalk Shed
2 jobs · most recent 03/03/2026
Suspended Scaffold Earthwork
FiledStatusContractorScope
03/03/2026Permit IssuedDORIA SCAFFOLDING LLCSuspended Scaffold
08/26/2025Permit IssuedSELCA CONSTRUCTION INCEarthwork
1 job · most recent 03/03/2026
Suspended Scaffold (SC)
FiledStatusContractorScope
03/03/2026Permit IssuedDORIA SCAFFOLDING LLCSuspended Scaffold (SC)
Building Lifecycle
All (218)Filed (31)Permit Issued (31)Signed Off (8)Violation (22)Inspection (13)Objection (80)Special Inspection (30)Tax Incentive (3)
01/01/2027
421-a(16) construction completed
09/01/2026
Inspection — Certified StandPipe - SD - Alarm Sys 64/09 - Finish
Certified
View inspection ↗
09/01/2026
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)
Certified
View inspection ↗
08/31/2026
Permit issued — Standpipe
X01277434-I1-EW-SD
08/31/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/27/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/22/2026
Signed off — Alteration
X00716188-I1
08/17/2026
Filed — Alteration
Sprinkler & Standpipe Application in Conjunction with NB Application
X01318156-P1
08/13/2026
Special inspection requirement — Post-installed Anchors
MINA HANNA
08/13/2026
Special inspection requirement — Sprinkler Systems
MINA HANNA
08/13/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MINA HANNA
08/13/2026
Special inspection requirement — Standpipe Systems
MINA HANNA
08/10/2026
Permit issued — Plumbing
X01318468-I1-PL
08/07/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY OVERHEAD PROTECTION AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X01311190-I1
08/07/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X01311174-I1
08/07/2026
Signed off — Alteration
X01343937-I1
08/07/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X01336095-I1
08/07/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY ROOF PROTECTION AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X01337522-I1
07/30/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY PERSONNEL HOIST AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
X01343224-I1
07/24/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
MINA HANNA
07/24/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
MINA HANNA
07/24/2026
Special inspection requirement — Fenestration areas
MINA HANNA
07/24/2026
Special inspection requirement — Metering
MINA HANNA
07/24/2026
Special inspection requirement — Insulation placement and R values
MINA HANNA
07/24/2026
Special inspection requirement — Fire-Resistance Rated Construction
MINA HANNA
07/24/2026
Special inspection requirement — Interior lighting power
MINA HANNA
07/24/2026
Special inspection requirement — Fenestration air leakage
MINA HANNA
07/24/2026
Special inspection requirement — Air barrier — testing
MINA HANNA
07/24/2026
Special inspection requirement — Exterior lighting power
MINA HANNA
07/24/2026
Special inspection requirement — Vestibules
MINA HANNA
07/24/2026
Special inspection requirement — Maintenance information
MINA HANNA
07/24/2026
Special inspection requirement — Electrical motors and elevators
MINA HANNA
07/24/2026
Special inspection requirement — Lighting controls
MINA HANNA
07/24/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
MINA HANNA
07/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MINA HANNA
07/24/2026
Special inspection requirement — Concrete - Cast-In-Place
MINA HANNA
07/24/2026
Special inspection requirement — Energy Code Compliance Inspections
MINA HANNA
07/24/2026
Special inspection requirement — Lighting in dwelling units
MINA HANNA
07/24/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
MINA HANNA
07/24/2026
Special inspection requirement — Air barrier - visual inspection
MINA HANNA
07/24/2026
Special inspection requirement — Protection of exposed foundation insulation
MINA HANNA
07/14/2026
Filed — New Building
PROPOSED CONSTRUCTION FENCE, NO CHANGE TO USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
X00684422-P3
07/14/2026
Special inspection requirement — Concrete - Cast-In-Place
MINA HANNA
07/14/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
MINA HANNA
07/14/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
MINA HANNA
07/14/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MINA HANNA
07/01/2026
Violation issued (ECB, open)
Construction
06/30/2026
Violation issued (ECB, open)
Construction
06/26/2026
Permit issued — General Construction
X00684422-I1-GC
06/15/2026
Permit issued — Earth Work
X01274933-I1-FO-EA
05/08/2026
Permit issued — Structural
X01275018-I1-ST
05/08/2026
Permit issued — Mechanical Systems
X01318118-I1-MS
05/01/2026
Permit issued — Sprinklers
X01318156-I1-EW-SD
04/30/2026
Permit issued — Sprinklers
X01318156-I1-EW-SP
04/15/2026
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
04/13/2026
Objection resolved — Addressed
04/03/2026
Permit issued — Suspended Scaffold
X01366389-I1-SC
03/26/2026
Permit issued — Suspended Scaffold
X01366389-I1-SC
03/24/2026
Inspection — Pass-Final PL - More than 10 Requested Floors
Pass
View inspection ↗
03/24/2026
Objection resolved — Addressed
Latest 60 of 218 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
EURO TECH DEVELOPERS5809/15/2026
OWNERS REP1407/08/2026
SELCA CONSTRUCTION703/22/2026
B SOSA ENTERPRISES203/22/2026
3073 VILLA203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/18/2020$790K—Private party → 3073 VILLA LLC— not available
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SALLY LOVE ASSOCIATES3803/21/2026
AE DESIGN SOLUTION1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SELCA CONSTRUCTION INCGeneral Contractor1707/08/2026
CORE SCAFFOLD SYSTEMS INC.General Contractor607/08/2026
PRIME PIPING & HEATING INFire Protection309/01/2026
DORIA SCAFFOLDING LLCGeneral Contractor204/09/2026
B SOSA ENTERPRISES CORPGeneral Contractor204/09/2026
A. M. PLUMBING COMPANYPlumbing208/11/2026
DYNAMIX SCAFFOLD GROUP LLGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CONCRETE SOLUTIONS LAB CO53441808/17/2026
SKYLINE RIGGING7880103/03/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStandpipePermit IssuedPRIME PIPING & HEATING IN08/31/2026
DOB NOWPlumbingPermit IssuedA. M. PLUMBING COMPANY08/10/2026
DOB NOWGeneral ConstructionPermit IssuedSELCA CONSTRUCTION INC06/26/2026
DOB NOWEarth WorkPermit IssuedSELCA CONSTRUCTION INC06/15/2026
DOB NOWStructuralPermit IssuedSELCA CONSTRUCTION INC05/08/2026
DOB NOWMechanical SystemsPermit IssuedSELCA CONSTRUCTION INC05/08/2026
DOB NOWSprinklersPermit IssuedPRIME PIPING & HEATING IN05/01/2026
DOB NOWSprinklersPermit IssuedPRIME PIPING & HEATING IN04/30/2026
DOB NOWSuspended ScaffoldPermit IssuedDORIA SCAFFOLDING04/03/2026
DOB NOWSuspended ScaffoldPermit IssuedDORIA SCAFFOLDING03/26/2026
DOB NOWPlumbingPermit IssuedA. M. PLUMBING COMPANY03/13/2026
DOB NOWProtection and Mechanical MethodsSigned-offCORE SCAFFOLD SYSTEMS INC03/03/2026
DOB NOWSupported ScaffoldSigned-offCORE SCAFFOLD SYSTEMS INC02/02/2026
DOB NOWProtection and Mechanical MethodsSigned-offCORE SCAFFOLD SYSTEMS INC02/02/2026
DOB NOWProtection and Mechanical MethodsSigned-offCORE SCAFFOLD SYSTEMS INC01/30/2026
DOB NOWProtection and Mechanical MethodsSigned-offCORE SCAFFOLD SYSTEMS INC10/31/2025
DOB NOWSidewalk ShedSigned-offCORE SCAFFOLD SYSTEMS INC10/31/2025
DOB NOWFoundationPermit IssuedSELCA CONSTRUCTION09/29/2025
DOB NOWSupport of ExcavationPermit IssuedSELCA CONSTRUCTION09/25/2025
DOB NOWConstruction FencePermit IssuedSELCA CONSTRUCTION09/22/2025
DOB NOWEarth WorkPermit IssuedSELCA CONSTRUCTION06/30/2025
DOB NOWConstruction FenceSigned-offSELCA CONSTRUCTION06/18/2025
DOB NOWFoundationPermit IssuedSELCA CONSTRUCTION04/19/2024
DOB NOWConstruction FenceSigned-offSELCA CONSTRUCTION04/19/2024
DOB NOWConstruction FenceSigned-offSELCA CONSTRUCTION01/11/2024
DOB NOWEarth WorkPermit IssuedSELCA CONSTRUCTION02/07/2023
DOB NOWFoundationPermit IssuedSELCA CONSTRUCTION10/20/2022
DOB NOWConstruction FenceSigned-offSELCA CONSTRUCTION09/30/2022
DOB NOWSidewalk ShedSigned-offDYNAMIX SCAFFOLD GROUP LL07/06/2022
DOB NOWFoundationPermit IssuedB SOSA ENTERPRISES CORP06/07/2022
DOB NOWConstruction FenceSigned-offB SOSA ENTERPRISES CORP04/26/2022
BIS—ISSUEDB SOSA ENTERPRISES CORP06/14/2022
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
09/01/2026Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
09/01/2026Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
08/31/2026Pass-Final CND-Occupancy InspectionPassView ↗
08/27/2026Pass-Final CND-Occupancy InspectionPassView ↗
04/15/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
03/24/2026Pass-Final PL - More than 10 Requested FloorsPassView ↗
02/05/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/11/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/11/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
12/03/2025Pass-Final PL - Up to 9 Requested FloorsPassView ↗
07/18/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/18/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/15/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 128
DateRequirementInspectorRole
08/13/2026Fire-Resistant Penetrations and JointsMINA HANNAspecial
08/13/2026Post-installed AnchorsMINA HANNAspecial
08/13/2026Sprinkler SystemsMINA HANNAspecial
08/13/2026Standpipe SystemsMINA HANNAspecial
07/24/2026Exterior Insulation and Finish Systems (EIFS)MINA HANNAspecial
07/24/2026Energy Code Compliance InspectionsMINA HANNAprogress
07/24/2026Concrete - Cast-In-PlaceMINA HANNAspecial
07/24/2026MeteringMINA HANNAenergy_progress
07/24/2026Maintenance informationMINA HANNAenergy_progress
07/24/2026Fenestration and door U-factor and product ratingsMINA HANNAenergy_progress
07/24/2026Lighting controlsMINA HANNAenergy_progress
07/24/2026Insulation placement and R valuesMINA HANNAenergy_progress
07/24/2026Electrical motors and elevatorsMINA HANNAenergy_progress
07/24/2026VestibulesMINA HANNAenergy_progress
07/24/2026Interior lighting powerMINA HANNAenergy_progress
07/24/2026Air barrier — testing MINA HANNAenergy_progress
07/24/2026Exterior lighting powerMINA HANNAenergy_progress
07/24/2026Fenestration areasMINA HANNAenergy_progress
07/24/2026Fenestration air leakageMINA HANNAenergy_progress
07/24/2026Air barrier - visual inspectionMINA HANNAenergy_progress
07/24/2026Protection of exposed foundation insulationMINA HANNAenergy_progress
07/24/2026Lighting in dwelling unitsMINA HANNAenergy_progress
07/24/2026Fire-Resistance Rated ConstructionMINA HANNAprogress
07/24/2026Fire-Resistant Penetrations and JointsMINA HANNAspecial
07/24/2026Structural Stability – Alterations of existing buildingsMINA HANNAspecial
Latest 25 of 128.
▾Documents — 216 on file (BIS + DOB NOW)
▸Plans & Drawings31
▸DOB NOWPlans/Sketch31
08/24/2026X00690012-I1Contact architect ↗
08/24/2026X00689986-I1Contact architect ↗
08/24/2026X00689878-I1Contact architect ↗
Showing 3 of 31 on file for this type
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION3
05/04/2022240316001Open ↗
02/03/2022220741963Open ↗
02/03/2022220741963Open ↗
▸BISWORK PERMIT APPLICATION1
06/21/2022220741963Open ↗
▸Zoning, Tax Lot & Property Records9
▸DOB NOWZoning Exhibit form (1-5)4
08/18/2026X00684422-P3Open ↗
08/18/2026X00684422-P1Open ↗
08/18/2026X00684422-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram4
08/18/2026X00684422-P3Open ↗
08/18/2026X00684422-I1Open ↗
08/13/2026X00684422-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026X00684422-I1Open ↗
▸Seals & Professional Certifications121
▸DOB NOWProgress Inspector Seal & Signature57
09/23/2026X01318118-I1Open ↗
09/23/2026X01318118-I1Open ↗
09/02/2026X00684422-P3Open ↗
Showing 3 of 57 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature31
08/24/2026X00690012-I1Open ↗
08/24/2026X00689986-I1Open ↗
08/24/2026X00716188-I1Open ↗
Showing 3 of 31 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature31
09/23/2026X01318118-I1Open ↗
09/23/2026X01318156-I1Open ↗
09/23/2026X01318118-I1Open ↗
Showing 3 of 31 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
05/04/2022240316001Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
05/04/2022240316001Open ↗
▸Trade Schedules & Equipment9
▸DOB NOWFDNY: Letter of No Objection4
08/17/2026X01318156-P1Open ↗
08/13/2026X00689878-I1Open ↗
08/13/2026X01318156-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/18/2026X00684422-I1Open ↗
08/13/2026X00684422-P1Open ↗
▸BISGAS CUT-OFF1
06/21/2022220741963Open ↗
▸BISSEWER/HOUSE CON SIGNOFF: DEP HC 0211
06/21/2022220741963Open ↗
▸DOB NOWStandpipe Alarms Drawings1
08/18/2026X00684422-I1—
▸Safety & Tenant Protection8
▸DOB NOWStreet Tree Checklist4
08/18/2026X00684422-P3Open ↗
08/18/2026X00684422-I1Open ↗
08/13/2026X00684422-P1Open ↗
Showing 3 of 4 on file for this type
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE1
06/21/2022220741963Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
06/21/2022220741963Open ↗
▸BISSRO MD ANTI-HARASSMENT CHECKLIST1
06/21/2022220741963Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X00684422-I1Open ↗
▸Environmental & Asbestos2
▸BISRODENT CONTROL1
06/21/2022220741963Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
06/21/2022220741963Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/13/2026X00693256-I1Open ↗
08/13/2026X01274933-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026X00693256-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026X00693256-I1Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION3
06/21/2022220741963Open ↗
06/21/2022220741963Open ↗
06/17/2022220741963Open ↗
▸BISTAP LETTER - DOM SVC : DEP-DOM1
06/21/2022220741963Open ↗
▸Cost, Insurance & Ownership1
▸BISPROJECT-SPECIFIC GL INSURANCE1
06/21/2022220741963Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
05/04/2022240316001Open ↗
▸BISEFILING COVER SHEET1
02/03/2022220741963Open ↗
▸Other Documents21
▸DOB NOWAdjoining Owners Notification4
08/18/2026X01274933-I1Open ↗
08/13/2026X00716166-I1Open ↗
08/13/2026X01275443-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlot Diagram4
08/13/2026X00716166-I1Open ↗
08/13/2026X00726589-I1Open ↗
08/13/2026X01275443-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSite Survey: Initial3
08/18/2026X00684422-P3Open ↗
08/18/2026X00684422-I1Open ↗
08/13/2026X00684422-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/18/2026X00684422-P3Open ↗
08/18/2026X00684422-I1Open ↗
08/13/2026X00684422-P1Open ↗
▸DOB NOWProperty Ownership Certification3
08/18/2026X00684422-P3Open ↗
08/18/2026X00684422-I1Open ↗
08/13/2026X00684422-P1Open ↗
▸BISCOMMUNITY BOARD NOTIFICATION1
06/21/2022220741963Open ↗
▸DOB NOWManufacturer's Specifications1
08/13/2026X01366389-I1Open ↗
▸DOB NOWEvaluation of Adjacent Building Report (BC 1817.3)1
08/13/2026X01275490-I1Open ↗
▸DOB NOWCalculations1
08/13/2026X01366389-I1Open ↗