ECB05/26/2023TEMPORARY CONSTRUCTION EQUIPMENT ONSITE-EXPIRED PERMIT.AS NOTED:AT TIME OF INSPECTION CONSTRUCTION SITE WAS CLOSED.I OBSERVED CONSTRUCTION PLYWOOD FENCE PERMIT AND SIDEWALK SHED PERMIT HAS EXPIRED ON 05/03/2023$6K due
ECB04/29/2022CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES PER CODE.AS NOTED:AT TIME OF INSPECTION AT ACTIVE JOBSITE OBSERVED WORK BEING DONE ON MULTIPLE FLOORS INCLUDING FRAMING PLUMBING REQUEST FOR COMPETENT PERSON$10K due
ECB09/15/2021FAILURE TO DESIGNATE ALTERNATE CONSTRUCTION SUPERINTENDENT AS REQUIRED. AT TIME OF INSPECTION AT AN ACTIVE CONSTRUCTION JOB SITE, I OBSERVED THE CONSTRUCTION SUPERINTENDENT HAS NOT VISITED THE JOB SITE FOR MORE$2K due
ECB06/02/20213301.2 CONTROL ACCESS ZONE(CAZ)3 FLOOR FORMING LEVEL.AT TIME OF INSPECTION OF THIS PROPOSED 8 STORY NEW BUILDING,I OBSERVED NO CAZ ON 3RD FLOOR FORMING LEVEL.NO GUARDRAIL SYSTEM IN PLACE AROUND THE FORMING STAI$12K due
ECB06/02/20213309.14 WINDOW PROTECTION.AT TIME OF INSPECTION,I OBSERVED CONCRETE FORMWORK WITHING 5FT FROM ADJOINING PROPERTY WINDOWS AT EXP2.ALSO ROOF PROTECTION DOES NOT EXTEND 20FT FROM CORNER OF EXP3 AND 4.NO WORK ALLOW$6K due
DOB03/20/2019SOIL/FDN WRK AFFECT ADJ PROP EXCAV FOR THE NEW MAT FDN UNDERMIN 40'OF LOT LINE WALL OF ADJ PROP EXP2 BY 2'DEEP HAS CAUSED SETTLE/STRL DMG RESULT IN VACATE OF 10 APTS ON 4/18/18 ADJ BEAR WALL REMAIN UNDERMINED WITH RISK OF FURTHER SETTLE/STRL DMG IMPROVE SUBGRADE COND BENEATH UND ERMIN BEAR WALL FILE PLNS BY 4/8/19 WRK BY 4/22/19 COMP WRK BY 5/10/19
ECB03/19/2019BC 3309.4 FAILURE TO MONITOR ADJOINING STRUCTURES FOR MOVEMENT IN ALL DIRECTION DURING(EXCATION) RELATED ACTIVITY THAT MAY ADVERSELY AFFECT ADJOINING STRUCTURES.8 STY NEW BUILDING UNDER CONST GROUND LVL ACTIVE$2K due
ECB03/13/2019PERMIT HOLDER/OWNER/WORKER EMPLOYER FAILED TO ENSURE EACH CONSTRUCTIONOR DEMOLITION WORKER SUCCESSFULLY COMPLETED THE REQUIRED TRAINING UNDER BC3321.1. DURING MY INSPECTION I OBSERVED MIGUEL MALDONOLDO GERONIMO$5K due
ECB03/13/2019PERMIT HOLDER/OWNER/WORKER EMPLOER FAILED TO ENSURE EACH CONSTRUCTION OR DEMOLITION WORKER SUCCESSFULLY COMPLETED THE REQUIRED TRAINING UNDER 3321.1. DURING MY INSPECTION I OBSERVED ANDRES LOPEZ ANDRES AT JOBSI$5K due
ECB03/13/2019PERMIT HOLDER/OWNER/WORKER EMPLOYER FAILED TO ENSURE EACH CONSTRUCTION OR DEMOLITION WORKER SUCCESSFULLY COMPLETED THE REQUIRED TRAINING UNDER 3321.10. DURING MY INSPECTION I OBSERVED JORGE L OLVERA ALRCON AT$5K due
ECB06/18/2018FAIURE TO PROVIDE WEATHER PROOFING INTEGRITY OF ADJ BLDG.AT TIME OF INSPECTION OBSERVED A CONSTRUCTION SITE AT FOUNDATION STAGE.DURING INSPECTION OBSERVED THAT THE CONTRACTOR DID NOT PROVIDE WEATHER PROOFING FO$6K due
ECB04/24/2018FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. THERE ARE MULTIPLE CRACKS IN THE FACADE & SEVERAL APTS AT 312 E 106 ST DUE TO CONSTRUCTION ACTIVIES AT THE JOB SITE. STRUCTURAL$-10,000 due
ECB10/04/2023AT THE TIME OF INSPECTION, OBSERVED INACTIVE 8 STORY NEW BUILDING CONSTRUCTION JOBSITE. I OBSERVED STANDPIPE GAUGE WAS INDICATING 0 PSI WHILE CODE SECTION 3303.8 REQUIRES THE STANDPIPE TO BE PRESSURIZED AT ALLNothing owed — awaiting certificate of correction
ECB08/29/2022UPON REQUEST, THE FOLLOWING DOCUMENTS WERE NOT PROVIDED: 1. FDNY WAIVER (OBSERVED NO ELEVATOR IN A STATE OF READINESS AND HOIST HAD BEEN REMOVED). 2. GC UNABLE TO PROVIDE LOADS-IMPOSED LETTER FOR EXPOSURE 2 OHPNothing owed — awaiting certificate of correction
ECB08/29/2022SUPPORTED PIPE SCAFFOLD (ALL EXPOSURES) FOUND TO BE CONTRARY TO APPROVED DRAWINGS. EXPOSURE #1 JUNIOR BEAMS UTILIZED AS FOOTING WERE NOT ON PLAN, PIPE SCAFFOLD OBSERVED INSTALLED ON BALCONY CONTRARY TO DRAWINGSNothing owed — awaiting certificate of correction
ECB11/13/2020TEMPORARY CONSTRUCTION EQUIPMENT ON-SITE: EXPIRED PERMIT: NOTED: OBSERVED AT LOCATION A TEMPORARY CONSTRUCTION FENCE ERECTED FOR A NEW BUILDING. PERMIT #122965416 WAS ISSUED FOR A TEMPORARY CONSTRUCTION FENCE.Nothing owed — awaiting certificate of correction
ECB03/13/2019PERMIT HOLDER/OWNER/WORKER EMPLOYER FAILED TO ENSURE EACH CONSTRUCTIONOR DEMOLITION WORKER SUCCESSFULLY COMPLETED THE REQUIRED TRAINING UNDER 3321.1. DURING MY INSPECTION I OBSERVED ANDRES LOPEZ ANDRES AT JOBSINothing owed — awaiting certificate of correction
ECB03/13/2019PERMIT HOLDER/OWNER/WORKERS ENPLOYER FAILED TO ENSURE EACH CONSTRUCTION OR DEMOLITION WORKER SUCCESSFULLY COMPLETED THE REQUIRED TRAINING UNDER BC3321.1. DURING MY INSPECTION I OBSERVED CARLOS CHUQUIRA AT JOBSINothing owed — awaiting certificate of correction
ECB03/13/2019PERMIT HOLDER/OWNER/WORKER EMPLOYER FAILED TO ENSURE EACH CONSTRUCTIONOR DEMOLITION WORKERS SUCCESSFULLY COMPLETED THE REQUIRED TRAINING UNDER BC3321.1. DURING MY INSPECTION I OBSERVED MIGUEL MALDONADO GERONIMONothing owed — awaiting certificate of correction
ECB03/13/2019PERMIT HOLDER/OWNER/WORKERS EMPLOYER FAILED TO ENSURE EACH CONSTRUCTION OR DEMOLITION WORKER SUCCESSFULLY COMPLETED THE REQUIRED TRAINING UNDER 3321.10. DURING MY INSPECTION I OBSERVED JORGE L ONERA ALRCON ATNothing owed — awaiting certificate of correction
ECB09/05/2017SEC. 3304.4.4 FAILURE TO PROVIDE 3 FOOT 6 INCH GUARDRAIL OR SOLID ENCLOSURE AROUND OPEN & ACCESSIBLE SIDES OF EXCAVATION. AT THE TIME OF INSPECTION IT WAS OBSERVED THAT ON A ACTIVE EXCAVATION SIDE CONTRACTORNothing owed — awaiting certificate of correction
ECB08/24/2017JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION. AT TIME OF INSPECTION JOB SITE FENCE @ EXPO #2 IS ENCROACHING ON ADJOINING PROPERTY MEANS OF EGRESS, FIRE ESCAPE. FENCE IS DIRECTLY BELOW FIRE ESCAPE LADDENothing owed — awaiting certificate of correction
ECB08/24/2017FAILURE TO PROVIDE APROVED/ACCEPTED CONSTRUCTION DOC AT JOB SITE AT TIME OF INSPECTION.AT TIME OF INSPECTION DESIGN DRAWINGS FOR JOB SITE FENCE NOT AVAILABLE FOR INSPECTION ACCORDING TO WORKER ON SITE PRODUCINGNothing owed — awaiting certificate of correction
ECB08/24/2017CONSTRUCTION SUPERINTENDANT FAIL TO MAINTAIN OR MAKE JOB SITE LOGS AVAILABLE.AT TIME OF INSPECTION ASKED FOR SUPERS LOG BOOK.THERE WERE NONE AVAILABE AT JOB SITE FOR INSPECTION.REM:PSWO PROVIDE SUPERS LOGS ATNothing owed — awaiting certificate of correction