← Back
Two family brick
3083 YATES AVENUE
BRONX · Pelham Gardens · BIN 2055955
💬 Discuss this project
1965Year Built
2Stories
B1Building Class
R5Zoning
2,508 sfGross Floor Area
2Units
Two family brick · 5,000 sf lot · 0.5 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 17 docs
Floor 11p · 1 filing · 17 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC212/06/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAMTECH RESTORATION CORP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAMTECH RESTORATION CORPGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854212/06/2024
Building Lifecycle
All (14)Filed (2)Permit Issued (1)Signed Off (1)Special Inspection (10)
01/30/2025
Signed off — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
X01147924-I1
12/10/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
12/10/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
12/10/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
12/10/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
12/10/2024
Special inspection requirement — Final
TOM PETERSEN
12/06/2024
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
X01147924-P1
12/06/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
12/06/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
12/06/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
12/06/2024
Special inspection requirement — Final
TOM PETERSEN
12/06/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
11/29/2024
Permit issued — Solar
X01147924-I1-SL
11/26/2024
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
X01147924-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP11/29/2024
1 project · most recent 11/04/2024
FiledStatusContractorScope
11/04/2024CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
12/10/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
12/10/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
12/10/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
12/10/2024Energy Code Compliance InspectionsTOM PETERSENprogress
12/10/2024FinalTOM PETERSENprogress
12/06/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
12/06/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
12/06/2024Energy Code Compliance InspectionsTOM PETERSENprogress
12/06/2024FinalTOM PETERSENprogress
12/06/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/20/2026X01147924-P1Request digital key ↗
08/20/2026X01147924-I1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature6
08/25/2026X01147924-I1Open ↗
08/25/2026X01147924-I1Open ↗
08/25/2026X01147924-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/25/2026X01147924-I1Open ↗
08/25/2026X01147924-I1Open ↗
08/23/2026X01147924-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/20/2026X01147924-I1Open ↗
08/20/2026X01147924-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/20/2026X01147924-P1Open ↗
08/20/2026X01147924-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026X01147924-I1Open ↗