| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 08/21/2025 | $1.2M | — | Private party → C3104 LLC | $417/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| CQ&J CORPORATION | 7 | 07/30/2026 |
| KNF SERVICES CROP | 1 | 10/06/2020 |
| GREEN DESIGN | 1 | 09/23/2020 |
| Representative | Filings | Most Recent |
|---|---|---|
| WM ARCH | 6 | 03/21/2026 |
| DANICO SERVICES | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| MEDITERRANEAN CONSTRUCTION CORP | General Contractor | 3 | 04/09/2026 |
| LAKHI GENERAL CONTRACTOR | General Contractor | 2 | 07/08/2026 |
| ARKENSTONE BUILDERS INC | General Contractor | 1 | 04/09/2026 |
| G.N. CONSTRUCTION INC | General Contractor | 1 | 07/08/2026 |
| PLBG P & H INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| SIMON | 7555 | 4 | 03/19/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Signed-off | ARKENSTONE BUILDERS INC | 03/30/2026 |
| DOB NOW | General Construction | Signed-off | MEDITERRANEAN CONSTRUCTIO | 12/16/2025 |
| DOB NOW | Plumbing | Signed-off | PLBG P & H INC | 09/11/2025 |
| DOB NOW | General Construction | Signed-off | MEDITERRANEAN CONSTRUCTIO | 09/11/2025 |
| DOB NOW | Sidewalk Shed | Signed-off | LAKHI GENERAL CONTRACTOR | 06/03/2021 |
| DOB NOW | Sidewalk Shed | Signed-off | LAKHI GENERAL CONTRACTOR | 10/07/2020 |
| DOB NOW | Construction Fence | Signed-off | EMPIRE CONSTRUCTION ASSOC | 09/24/2020 |
| BIS | OT | ISSUED | ELITE QUALITY CONSTRUCTIO | 01/29/2021 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/30/2026 | Signed-off | ARKENSTONE BUILDERS INC | Heating and Air Conditioning Systems | Heat / Cool Cooper & Hunter CH-RVHP36M-230VO 42,000 BTU · Condensing Unit ×2 CH-RVHP28-230VO 36,000 BTU · Heat Pump Outdoor ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/30/2026 | Signed-off | PLBG P & H INC | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/15/2025 | Permit Issued | BDS ELECTRIC CORP. | General Wiring, Lighting |
| 08/25/2020 | Permit Issued | K.N.C ELECTRIC INC | — |
| Date | Type | Result | Report |
|---|---|---|---|
| 06/11/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 04/23/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 04/13/2026 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 11/20/2025 | Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments) | Certified | View ↗ |
| 11/18/2025 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 10/22/2025 | Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet) | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/31/2026 | Maintenance information | CALVIN TRAN | energy_progress |
| 07/31/2026 | Energy Code Compliance Inspections | CALVIN TRAN | progress |
| 07/31/2026 | HVAC-R and service water heating equipment | CALVIN TRAN | energy_progress |
| 07/31/2026 | HVAC-R and service water piping design and insulation | CALVIN TRAN | energy_progress |
| 07/31/2026 | HVAC-R and service water heating system controls | CALVIN TRAN | energy_progress |
| 07/30/2026 | HVAC-R and service water piping design and insulation | CALVIN TRAN | energy_progress |
| 07/30/2026 | HVAC-R and service water heating system controls | CALVIN TRAN | energy_progress |
| 07/30/2026 | HVAC-R and service water heating equipment | CALVIN TRAN | energy_progress |
| 07/30/2026 | Maintenance information | CALVIN TRAN | energy_progress |
| 07/30/2026 | Energy Code Compliance Inspections | CALVIN TRAN | progress |
| 03/19/2026 | HVAC-R and service water piping design and insulation | CALVIN TRAN | energy_progress |
| 03/19/2026 | Maintenance information | CALVIN TRAN | energy_progress |
| 03/19/2026 | HVAC-R and service water heating equipment | CALVIN TRAN | energy_progress |
| 03/19/2026 | HVAC-R and service water heating system controls | CALVIN TRAN | energy_progress |
| 03/19/2026 | Energy Code Compliance Inspections | CALVIN TRAN | progress |
| 03/18/2026 | Metering | CALVIN TRAN | energy_progress |
| 03/18/2026 | Air barrier - visual inspection | CALVIN TRAN | energy_progress |
| 03/18/2026 | Insulation placement and R values | CALVIN TRAN | energy_progress |
| 03/18/2026 | Fire-Resistant Penetrations and Joints | SIMON JIANG | special |
| 03/18/2026 | Fenestration air leakage | CALVIN TRAN | energy_progress |
| 03/18/2026 | Mechanical Systems | SIMON JIANG | special |
| 03/18/2026 | Final | CALVIN TRAN | progress |
| 03/18/2026 | Energy Code Compliance Inspections | CALVIN TRAN | progress |
| 03/18/2026 | Fire-Resistance Rated Construction | CALVIN TRAN | progress |
| 03/18/2026 | Fenestration and door U-factor and product ratings | CALVIN TRAN | energy_progress |