ECB04/09/2026OBSERVED FENCE PERMIT Q00900489-I1-FN EXPIRED ON 08/15/24. LACK OF SUPERVISION IS POTENTIAL HAZARD FOR THE SITE AND THE PUBLIC.$6K due
DOB03/07/2024BASED ON COMMISSIONERS SUSPENSION NOTIFICATION ON 2/28/2024 INTENDS TO REVOKE ALL PLUMBING APPROVALS AND PERMIT ISSUED UNDER JOB #421623951 DUE TO SUSPENSION OF LICENSE MASTER PLUMBER # 002245 STOP ALL PLUMBING WORK UNDER ABOVE MENTIONED PERMIT IMMEDIATELY.
ECB06/17/2024BC 3301.13 FAILURE TO HAVE CONSTRUCTION SUPERINTENDENT/COMPETENT PERSON ON SITE AS REQUIRED. OBSVD 4 STR ALT1 JOB W/ CS STILL ASSIGNED TO THE JOB/APP- W/ 2 WORKERS ON SITE PERFORMING HVAC WORK. UPON ASKING WORKNothing owed — awaiting certificate of correction
ECB06/17/2024OBSERVED TWO 6-8FT WIDE SECTION OF CONSTRUCTION/JOBSITE FENCE MISSING IN THE EXP#3 REAR YARD, 1 SECTION ALONG THE EXP#2 PROPERTY LINE, AND THE OTHER ALONG THE EXP#4 PROPERTY LINE- WITH THE BUILDING UNDER ALTERANothing owed — awaiting certificate of correction
ECB06/17/2024OBSERVE VARIOUS DEBRIS/MATERIAL SCATTERED THROUGHOUT MULTIPLE FLOORS, AS WELL AS EXTENSION CORDS RUNNING THROUGH STAIRCASES AND ON TOP OF THE STEPS. THESE CONDITIONS CREATE TRIPPING HAZARDS FOR ALL PERSONNEL ONNothing owed — awaiting certificate of correction
ECB06/17/2024OBSERVED UNFINISHED WORK ON THE EXP#3 BALCONIES, LOCATED OVER AND WITHIN 5FT OF THE EXP#4 ADJ PROPERTY- PERMANENT RAILING NOT INSTALLED, BOTTOM OF BALCONY SLABS NOT FINISHED- WHILE NO ADEQUATE PROTECTION HAD BENothing owed — awaiting certificate of correction
ECB09/28/2023TIME OF INSPECTION AT 4 STORY ALTERATION SITE OBSERVED EXTERIOR AND INTERIOR WORK IN PROGRESS , UPON FURTHER OBSERVED INADEQUATE HOUSE KEEPING AT EXPOSURE 1, 1ST FLOOR AND EXPOSURE 3 REAR OF THE BUILDING BLOCKINothing owed — awaiting certificate of correction
ECB09/28/2023AT TIME OF MY INSPECTION 4 STORY ALTERATION ACTIVE SITE OBSERVED EXTERIOR AND INTERIOR WORK IN PROGRESS. UPON REQUEST TO SEE DOB APPROVED STRUCTURAL DRAWING, COLD FORM STREEL JOIST SPECIAL ENGINEER REPORT AND MNothing owed — awaiting certificate of correction
ECB09/27/2023TIME OF INSPECTION AT 4 STORY ALTERATION ACTIVE SITE OBSERVED EXTERIOR AND INTERIOR WORK IN PROGRESS, UPON FURTHER OBSERVED UNSAFE SCAFFOLD AT EXPOSURE 1 AND 3-MISSING GUARD RAILS, TOE-BOARD, INADEQUATE NETTINGNothing owed — awaiting certificate of correction
ECB06/16/2023OBSERVED INADEQUATE SCAFFOLD WITH MISSING MIDRAILS,UNSAFE PLANKING PLATFORM NOT TIED DOWN IN BC3314.5.5, CREATES HAZARD TO WORKERS OF FALLS FROM HEIGHT OF 35 FEET LEADS TO INJURIES OR FATAL. STOP ALL EXTERIOR WNothing owed — awaiting certificate of correction
ECB09/16/2021FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33-SSP-C.S. LOG BOOK. NOTED: AT TIME OF MY INSPECTION OF AN ALTERATION TYPE 1,CONSTRUCTION IN PROGRESS AT THE UNDERPINNING STAGE,UPON ENTERINNothing owed — awaiting certificate of correction
ECB09/16/2021SEC. BC 3301.1.2 NO ADEQUATE FIRE EXTINGUISHERS ON SITE. NOTED: AT TIME OF MY INSPECTION OF AN ALTERATION TYPE 1,4 STY BLDG CONSTRUCTION IN PROGRESS AT THE UNDERPINNING/FOUNDATION PHASE,UPON ENTERING THE SITE,INothing owed — awaiting certificate of correction
ECB09/16/2021CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES PER CODE. NOTED: AT TIME OF MY INSPECTION OF AN ALT-1,4 STY BLDG FOR WHICH THE ABOVE MENTIONED RESPONDENT IS THE CONSTRUCTION SUPERINTENDENT I OBSERVED THENothing owed — awaiting certificate of correction