← Back
Three families
31-58 31 STREET
QUEENS · BIN 4007565
💬 Discuss this project
1940Year Built
2Stories
C0Building Class
C4-3Zoning
2,100 sfGross Floor Area
3Units
Three families · Owner of record: ART HAUS 31, LLC · 2,205 sf lot · 0.95 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 1 filing · 20 docs
BulkheadUnder Construction1p · 1 filing · 20 docs
Floor 5Under Construction2p · 1 filing · 20 docs
Floor 4
Floor 3
Floor 2
Floor 1Under Construction1p · 1 filing · 20 docs
CellarUnder Construction1p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ART HAUS 31, LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/30/2015$1.2M—Private party → ART HAUS 31, LLC$571/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STROH ENGINEERING SERVICES, P.C.208/10/2026
HCN DESIGN507/30/2026
SIDERIS KEFALAS ENGINEERS PC303/20/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HCN DESIGN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
N.Y. PREFERRED DEVELOPMENTGeneral Contractor309/25/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
STROH ENGINEERING SERVICE3316208/10/2026
Building Lifecycle
All (108)Filed (10)Permit Issued (3)Objection (65)Special Inspection (30)
09/24/2026
Permit issued — Construction Fence
Q01254688-Z2-FN
08/10/2026
Filed — Full Demolition
THIS IS A FULL DEMOLITION OF 2 STORY RESIDIENTIAL HOUSE. GARAGE FILED UNDER DOB NOW JOB #Q01290838-I1. FENCE FILED UNDER SEPARATE APPLICATION .
Q01290836-P1
07/30/2026
Filed — New Building
Herewith filing for the installation of sprinkler systems for proposed 6-story, mixed use, new building.
Q01254688-S3
05/22/2026
Permit issued — Full Demolition
Q01290836-I1-FD
05/19/2026
Permit issued — Construction Fence
Q01254688-Z2-FN
05/08/2026
Objection raised — Structural
05/08/2026
Objection resolved — Addressed
05/08/2026
Objection raised — Mechanical
05/08/2026
Objection raised — Structural
05/08/2026
Objection resolved — Addressed
05/08/2026
Objection raised — Mechanical
05/08/2026
Objection raised — Admin
05/08/2026
Objection raised — Structural
05/08/2026
Objection resolved — Addressed
05/08/2026
Objection raised — Mechanical
05/08/2026
Objection raised — Structural
05/08/2026
Objection resolved — Addressed
05/08/2026
Objection raised — Scope
05/08/2026
Objection raised — Admin
05/08/2026
Objection resolved — Addressed
05/08/2026
Objection raised — Structural
05/08/2026
Objection resolved — Addressed
05/06/2026
Filed — New Building
Herewith filing for the installation of sprinkler systems for proposed 6-story, mixed use, new building.
Q01254688-Z2
04/18/2026
Objection raised — Scope
04/18/2026
Objection resolved — Addressed
04/15/2026
Objection raised — Structural
04/15/2026
Objection raised — Structural
04/15/2026
Objection raised — Scope
04/15/2026
Objection raised — Structural
04/15/2026
Objection raised — Structural
04/15/2026
Objection resolved — Resolved
04/13/2026
Objection raised — Inspections
04/13/2026
Objection resolved — Addressed
04/13/2026
Objection raised — Plumbing
04/13/2026
Objection resolved — Addressed
04/13/2026
Objection raised — Fire_Protection
03/30/2026
Objection raised — Structural
03/30/2026
Objection raised — Structural
03/30/2026
Objection raised — Structural
03/30/2026
Objection raised — Inspections
03/30/2026
Objection raised — Structural
03/20/2026
Filed — New Building
Herewith filing for the installation of sprinkler systems for proposed 6-story, mixed use, new building.
Q01254688-S6
03/18/2026
Filed — New Building
Herewith filing for the installation of sprinkler systems for proposed 6-story, mixed use, new building.
Q01254688-S5
03/17/2026
Filed — New Building
Herewith filing for the installation of sprinkler systems for proposed 6-story, mixed use, new building.
Q01254688-S7
03/13/2026
Objection resolved — Addressed
03/13/2026
Objection resolved — Addressed
03/13/2026
Objection resolved — Addressed
03/13/2026
Objection resolved — Addressed
03/13/2026
Objection resolved — Addressed
03/11/2026
Objection raised — Zoning
03/04/2026
Filed — New Building
Herewith filing for the installation of sprinkler systems for proposed 6-story, mixed use, new building.
Q01254688-S1
02/18/2026
Filed — New Building
Herewith filing for the installation of sprinkler systems for proposed 6-story, mixed use, new building.
Q01254688-S2
02/11/2026
Special inspection requirement — Structural Cold-Formed Steel
02/10/2026
Objection resolved — Addressed
01/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/20/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
01/20/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
01/20/2026
Special inspection requirement — HVAC-R and service water heating equipment
01/20/2026
Special inspection requirement — HVAC-R and service water heating system controls
Latest 60 of 108 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedN.Y. PREFERRED DEVELOPMENT09/24/2026
DOB NOWFull DemolitionPermit IssuedN.Y. PREFERRED DEVELOPMENT05/22/2026
DOB NOWConstruction FencePermit IssuedN.Y. PREFERRED DEVELOPMENT05/19/2026
1 project · most recent 07/30/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/30/2026Permit IssuedN.Y. PREFERRED DEVELOPMENHeating and Air Conditioning Systems
Heat / Cool
Daikin RTXA24AAVJU 23,000 BTU · Condensing Unit ×10
1 project · most recent 07/30/2026
Sprinkler System
FiledStatusContractorScope
07/30/2026——Sprinkler System
1 project · most recent 07/30/2026
Storm Water/Sanitary
FiledStatusContractorScope
07/30/2026——Storm, Water/Sanitary
1 project · most recent 04/28/2021
FiledStatusContractorScope
04/28/2021Permit IssuedHYLAN DATACOM & ELECL LLC—
1 project · most recent 07/30/2026
Concrete
FiledStatusContractorScope
07/30/2026Permit IssuedN.Y. PREFERRED DEVELOPMENConcrete
▾Special Inspection Requirements (DOB NOW) — 46
DateRequirementInspectorRole
02/11/2026Structural Cold-Formed Steel—special
01/20/2026Fire-Resistant Penetrations and Joints—special
01/20/2026Fire-Resistant Penetrations and Joints—special
01/20/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
01/20/2026HVAC-R and service water piping design and insulation—energy_progress
01/20/2026HVAC-R and service water heating equipment—energy_progress
01/20/2026HVAC-R and service water heating system controls—energy_progress
01/20/2026Maintenance information—energy_progress
01/20/2026Maintenance information—energy_progress
01/20/2026Duct leakage testing, insulation and design—energy_progress
01/20/2026Shutoff dampers—energy_progress
01/20/2026HVAC-R and service water piping design and insulation—energy_progress
01/20/2026HVAC-R and service water heating system controls—energy_progress
01/20/2026HVAC-R and service water heating equipment—energy_progress
12/30/2025Final—progress
12/30/2025Mechanical Systems—special
11/21/2025Post-installed Anchors—special
11/21/2025Concrete - Cast-In-Place—special
11/21/2025Subsurface Investigations (Borings/Test Pits)—special
11/21/2025Concrete - Cast-In-Place—special
11/21/2025Masonry—special
11/21/2025Post-installed Anchors—special
11/21/2025Subgrade Inspections—special
10/27/2025Designated Seismic System—special
10/27/2025Final—progress
Latest 25 of 46.
▾Documents — 42 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/18/2026Q01290836-P1Request digital key ↗
08/18/2026Q01290836-I1Request digital key ↗
08/16/2026Q01254688-Z2Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/15/2026Q01254688-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/15/2026Q01254688-I1Open ↗
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/18/2026Q01290836-P1Open ↗
08/18/2026Q01290836-I1Open ↗
08/16/2026Q01254688-S1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
08/31/2026Q01290836-I1Open ↗
▸Trade Schedules & Equipment4
▸DOB NOWElectric Cut-Off1
08/18/2026Q01290836-I1Open ↗
▸DOB NOWWater Cut-Off1
08/18/2026Q01290836-I1Open ↗
▸DOB NOWGas Cut-Off1
08/18/2026Q01290836-I1Open ↗
▸DOB NOWSewer Cut-Off1
08/18/2026Q01290836-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/15/2026Q01254688-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/15/2026Q01254688-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/18/2026Q01290836-I1Open ↗
08/18/2026Q01290836-P1Open ↗
▸DOB NOWRodent Control1
08/18/2026Q01290836-I1Open ↗
▸Inspections & Test Reports1
▸DOB NOWSOIL REPORT1
08/15/2026Q01254688-S2Open ↗
▸Other Documents9
▸DOB NOWProperty Ownership Certification3
08/18/2026Q01290836-P1Open ↗
08/18/2026Q01290836-I1Open ↗
08/15/2026Q01254688-I1Open ↗
▸DOB NOWStructure Photographs2
08/18/2026Q01290836-P1Open ↗
08/13/2026Q01290836-I1Open ↗
▸DOB NOWCommunity Board Notification1
08/18/2026Q01290836-I1Open ↗
▸DOB NOWFull Demo: 10-Day Notice1
08/18/2026Q01290836-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/15/2026Q01254688-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/15/2026Q01254688-I1Open ↗