DOB05/16/2001WORK WITHOUT PERMIT. NOTED: AT FRONT OF BLDG THE GROUND HAS BEEN EXCAVATED 36"X 8' CREATING A FLIGHT OF CONCRETE STAIRS WITH A TOTAL RISE OF APPROX 72" LEADING TO A 3'X 7' METAL RIGHT HANDED DOOR. NOTE: DOOR HAS BEEN INSTALLED THRU THE STRUCTURAL WALL SUPPORTING BRICK FACE REMEDY: PROVIDE ENGINEERS REPORT AS TO THE STRUCTURAL STABILITY
DOB12/09/1999V-DOB VIOLATION - ACTIVE
DOB12/09/1999V-DOB VIOLATION - ACTIVE
ECB01/14/2000SECOND MEANS OF EGRESS FOR FOUR -STORY BUILDING,CONSTRUCTION CLASS 2B. IS NOT PROVIDED AS PER SECTION 27-366 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/14/2000STAIR ENCLOSURE DOES NOT COMPLY WITH THE REQUIRED FIRE RESISTANCE RATING, IN THAT THE BUILDING IS BUILT AS A FOUR-STORY, OCCUPANCY GROUPJ-2, WHICH REQUIRES A TWO-HOUR FIRE RATED ENCLOSURES AS PER SECTIONNothing owed — awaiting certificate of correction
ECB01/14/2000HANDICAP ACCESS TO THE BUILDING IS NOT PROVIDED AS PER SECTION 27-292.5(A) OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/14/2000FIRE STOPPING AT PARTY WALLS OF BUILDING IS NOT PROVIDED, CONTRARY TO REQUIREMENTS OF SECTION 27-332 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/14/2000SKYLIGHT AND VENTILATORS FOR STAIR ENCLOSURE ARE NOT PROVIDED AS PER SECTION 27-375 (I) (4) C OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/14/2000ROOF ACCESS IS MISSING IN THAT BUILDING MORE THAN THREE STORIES OR FORTY FEET HIGH SHALL HAVE AN ACCESS TO THE ROOF BY AT LEAST ONE INTERIOR STAIR AS PER SECTION 27-375 (I) (4) K OF THE BUILDING CODE . REMEDY:FNothing owed — awaiting certificate of correction
ECB01/14/2000EXISTING APARTMENT DOORS OPEN DIRECTLY INTO STAIR ENCLOSURE CONTRARY TO SECTION 27-375 (J) .REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/14/2000PARAPET ON EXTERIOR WALL OF BUILDING IS NOT PROVIDED AT THE ROOF OF THE FOURTH FLOOR AS PER SECTION 27-333 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/14/2000BUILDING DOES NOT COMPLY WITH QUALITY HOUSING PROGRAM AS PER SECTIONS X8-12 AND 28-22 OF THE ZONING RESOLUTION IN THAT THERE ARE NO DOUBLE- GLAZED WINDOWS NOR REQUIRED PLANTINGS. REMEDY: FILE PLANS TO LEGALIZE.Nothing owed — awaiting certificate of correction
ECB01/14/2000STRUCTURAL DEFECTS WHICH VIOLATE REFERENCE STANDARD RS10-5B WERE OBSERVED, IN THAT: 1) NO STRAP BRACING FOR "C" JOISTS PRESENT. 2) AN- CHORAGE BETWEEN JOIST AND BEARING OR NON-BEARING WALL WAS NOT PROVIDEDNothing owed — awaiting certificate of correction
ECB01/14/2000WOOD STAIR BETWEEN CELLAR AND FIRST FLOOR IS NOT PERMITTED AS PER SECTION 27-375 (H) REMEDY: MAKE STAIR OF NON -COMBUSTIBLE MATERIAL AS REQUIRED BY CODE AND OBTAIN INSPECTIONNothing owed — awaiting certificate of correction
ECB01/14/2000BULKHEAD OF FIRE RESISTANT CONSTRUCTION MEETING THE REQUIREMENTS OF SUBCHAPTER FIVE OF THE BUILDING CODE IS NOT PROVIDED AS PER 27-375(K) (1). REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/13/2000EXISTING APARTMENT DOORS OPEN DIRECTLY INTO STAIR ENCLOSURE CONTRARY TO SECTION 27-375(J) OF THE BUILDING CODE. FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/13/2000SKYLIGHT AND VENTILATORS FOR STAIR ENCLOSURE ARE NOT PROVIDED AS PER SECTION 37-375(I)(4)C OF THE BUILDING CODE. FILE PLANS TO LEGALIZE ID FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/13/2000BULKHEAD OF FIRE RESISTANT CONSTRUCTION MEETING THE REQUIREMENTS OF SUBCHAPTER FIVE OF THE BUILDING VODE IS NOT PROVIDED AS PER 27-375 (K)(1). FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/13/2000STAIR ENCLOSURE DOES NOT COMPLY WITH THE REQUIRED FIRE RESISTANCE RATING IN THAT THE BUILDING IS BUILT AS A FOUR STORY, OCCUPANCY GROUP J-2 ,WHICH REQUIRES A TWO-HOUR FIRE RATED ENCLOSURE AS PER SECTION 27-375Nothing owed — awaiting certificate of correction
ECB01/13/2000HANDICAP ACCESS TO THE BUILDINF IS NOT PROVIDED AS PER SECTION 27-292.5(A) OF THE BUILDING CODE. FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/13/2000PARAPET ON EXTERIOR WALL OF BUILDING IS NOT PROVIDED AT THE ROOF OF THE FOURTH FLOOR AS PER SECTION 27-333 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/13/2000ROOF ACCESS IS MISSING IN THAT BUILDING MORE THAN THREE STORIES OR FOURTY FEET HIGH SHALL HAVE AN ACCESS TO THE ROOF BY AT LEAST ONE INTERIOR STAIR AS OER SECTION 27-375 (K) OF THE BUILDING CODE. FILE TO LEGNothing owed — awaiting certificate of correction
ECB01/13/2000FIRE STOPPING AT PARTY WALLS OF BUILDING IS NOT PROVIDED , CONTRARY TO REQUIREMENTS OF SECTION 27-332 OF THE BUILDING CODE. REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLENothing owed — awaiting certificate of correction
ECB01/13/2000STRUCTURAL DEFECTS WHICH VIOLATES REFERENCE STANDARD RS10-5B WERE OBSERVED , IN THAT : (I) NO STRAP BRACING FOR "C" JOISTS PRESENT . (II) ANCHORAGE BETWEEN JOIST AND BEARING AND NON-BEARING WALL WAS NOT PROVIDNothing owed — awaiting certificate of correction
ECB01/13/2000BUILDING DOES NOT COMPLY WITH QUALITY HOUSING PROGRAM AS PER SECTIONS 28-12 AND 28-22OF THE ZONING RESOLUTION IN THAT THERE ARE NO DOUBLE GLAZED WINDOWS NOR REQUIRED PLANTINGS. FILE PLANS TO LEGALIZE.Nothing owed — awaiting certificate of correction
ECB01/13/2000REAR EXTENSION AT REAR YARD. (MIKVA) IS NOT A PERMITTED OBSERVATION AT REAR YARD AS PER ZONING RESOLUTION 23-44. REMEDY: FILE PLANS TO LEGALIZENothing owed — awaiting certificate of correction
ECB01/13/2000SECOND MEANS OF EGRESS FOR FOUR STORY BUILDING CONSTRUCTION CLASS IIB,IS NOT PROVIDED AS PR SECTION 27-366 OF THE BUILDING CODE. FILE PLANS TO LEGALIZE IF FEASIBLE.Nothing owed — awaiting certificate of correction
ECB01/13/2000WOOD STAIR BETWEEN CELLAR AND FIRST FLOOR IS NOT PERMITTED: AS PER SECTION 27-375 (H) REMEDY: MAKE STAIR OF NON-COMBUSTIBLE MATERIAL , AS REQUIRED BY CODE , AND OBTAIN D.O.B INSPECTIONNothing owed — awaiting certificate of correction
ECB01/06/2000NO SECOND MEAN OF EGRESS WAS PROVIDED FOR THE SYNAGOGUE AS PER SECTION 27-366 REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE - NO DAILY PENALTIESNothing owed — awaiting certificate of correction
ECB01/06/2000HANDICAP ACCESS TO SYNAGOGUE IS NOT PROVIDE AS PER 27-292 5(A) REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE - NO DAILY PENALTIESNothing owed — awaiting certificate of correction
ECB01/06/2000SPRINKLER SYSTEM FOR THE SYNAGOGUE IS NOT PROVIDED AS PER 27-954(2). REMEDY: FILE PLANS TO LEGALIZE IF FEASIBLE - NO DAILY PANALTIES.Nothing owed — awaiting certificate of correction
ECB01/06/2000CELLAR WAS CONVERTED INTO SYNAGOUGE WITHOUT PROPER FILING AND WITHOUT PERMIT AS PER SECTION 27-147 OF THE BUILDING CODE. REMEDY; FILE PLANS TO LEGALIZE IF FEASIBLE - NO DAILY PENALTIESNothing owed — awaiting certificate of correction