ECB07/28/2026REMOVED OR DEFACED A WRITTEN POSTED VACATE ORDER. NOTED: AT TIME OF INSPECTION - PVO POSTED AT FRONT ENTRY DOOR ON 05/08/2026 WAS OBSERVED REMOVED., COMPLY WITH CODE$5K due
ECB07/09/2026WORK WITHOUT A PERMIT. AT THE TIME OF INSPECTION, TEMPORARY SHORING CONSISTING OF SCREW JACKS WAS OBSERVED AT THE EXPOSURE 1 BASEMENT SUPPORTING THE MASONRY ENTRANCE STOOP. NO PERMIT WAS ON FILE FOR THE INSTALL$2K due
DOB07/09/2026REQUESTING A STRUCTURAL STABILITY REPORT DUE TO CRACKS OBSERVED AT EXPOSURE 1 MASONRY STOOP AT 1ST STORY. TEMPORARY SHORING WITH INSTALLED SCREW JACK HAS BEEN INSTALLED TO SUPPORT STRUCTURE ABOVE WITH NO PERMITS ON FILE.
HPD07/07/2026§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT VESTIBULE , 1st STORY
HPD07/07/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE METAL LANDING AT EAST AT FRONT AREAWAY
HPD07/07/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT SKYLIGHT
HPD07/07/2026§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLE CHAINED TO SCUTTLE LADDER AT PUBLIC HALL, 4th STORY
HPD07/07/2026§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIREDOOR IN THE KITCHEN LOCATED AT APT 1W, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD07/07/2026§ 27-2005 ADM CODE PROVIDE A LOWER SCREEN MESH AT SKYLIGHT
HPD07/07/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BRICK AND MORTAR AT PARAPET WALL AT EAST EXTERIOR WALL
HPD07/07/2026§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOCKABLE SLIDE BOLT AT EGRESS FIREDOOR . IN THE KITCHEN LOCATED AT APT 1W, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD07/07/2026§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT STACK AT BUILDING FRONT AT FIRE ESCAPE
HPD08/11/2025§ 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD06/10/2025§ 27-2056.4(H) AND 27-2056.17 ADM CODE -CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES.
HPD06/10/2025§ 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS.
HPD03/21/2025§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD03/21/2025§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD03/21/2025§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE (HINGE) AT APARTMENT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 3W, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD12/14/2024§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL, EAST WALL, WEST WALL, 1st WINDOW FRAME FROM EAST AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 4W, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD12/14/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4W, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD12/14/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4W, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD12/14/2024§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL, EAST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4W, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD12/14/2024§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) EAST WALL, WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4W, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD11/07/2023§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF BELL BUZZER INTERCOM SYSTEM INACCESSABLE FROM BUILDING FRONT
HPD11/07/2023§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER USING NUTS AND BOLTS AT FIRST FIRE ESCAPE FROM EAST AT BUILDING FRONT
HPD10/04/2018§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING , DOUBLE CYLINDER LOCK AT EAST GATE BUILDING FRONT
HPD04/01/2015§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK INSTALED AT GATE LEADING TO CELLAR APARTMENT AT FRONT AREAWAY
DOB05/15/2014VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
DOB01/01/2009V-DOB VIOLATION - ACTIVE
DOB01/03/2008V-DOB VIOLATION - ACTIVE
DOB01/19/2007V-DOB VIOLATION - ACTIVE
ECB07/09/2026FAILURE TO MAINTAIN ENTRANCE STOOP. AT THE TIME OF INSPECTION, THE MASONRY ENTRANCE STOOP AT EXPOSURE 1 1ST STORY EXHIBITED STRESS CRACKS, AND TEMPORARY SCREW-JACK SHORING WAS INSTALLED BELOW THE STOOP, INDICATHearing held — result not yet published$2K proposed
ECB05/07/2026W/O A PERMIT. NOTED: FULL HEIGHT PARTITION WALLS WERE REMOVED & ERECTED TO CHANGE FLOOR LAYOUT: SEE SIGNED OFF FLR PLANS FOR JOB # 220091415., OBTAIN ALL PERMITSHearing held — result not yet published$1K proposed
ECB05/07/2026W/O A PERMIT. NOTED: WATER & WASTE LINES AT CELLAR OBSERVED REMOVED FOR A 2 PC BTHRM (TOILET, SINK); INSTALLED AT REAR FOR A TOILET. SEE SIGNED OFF FLR PLANS FOR JOB # 220091415., OBTAIN ALL PERMITSHearing held — result not yet published$1K proposed
ECB05/07/2026CONTRARY TO FLR PLANS FOR SIGNED OFF JOB # 220091415 - REAR STORAGE & UTILITY RM AREA WAS OBSERVED CREATED & OCCUPIED AS A BDRM W/O NATURAL LIGHT & VENTILATION. ALSO, CONTRARY TO HPD MDR # 208821, BUILDING CREAHearing held — result not yet published$2K proposed
ECB05/07/2026FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1 (2008 CODE); 27-366; BC 102.1 (2014 CODE). NOTED: AT TIME OF INSPECTION CELLAR APTHearing held — result not yet published$12K proposed
ECB08/14/2017B254,36. 36-AS PER CLASS 254-36. BOILER NOT REGISTERED AS PER DOB RECORDS. CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION.Nothing owed — awaiting certificate of correction