← Back
Convent
310 PROSPECT PARK WEST
BROOKLYN · BIN 3017300
💬 Discuss this project
1968Year Built
4Stories
M4Building Class
R5BZoning
98,112 sfGross Floor Area
1Units
LL97 Covered1 Open Violation ▸FDNY Report ↗
Convent · Owner of record: ROCKLYN ECCLESIASTICAL CORP. · 28,546 sf lot · 3.44 FAR built · Flood zone X
Locations of Work
ElectricalMechanicalPlumbing
Roof4p · 5 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ROCKLYN ASSET CORP503/22/2026
ROCKLYN ECCLESIASTICAL CORP.503/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYPL303/21/2026
LEWSAN CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BONDEE ENTERPRISES INCPlumbing407/08/2026
CRAINE AIR CONDITIONING INCGeneral Contractor203/21/2026
ALED TECHNOLOGIES INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
EC SPECIAL INSPECTIONS8355112/13/2023
HOWARD L ZIMMERMAN ARCHIT1712305/24/2022
Building Lifecycle
All (67)Filed (8)Permit Issued (4)Signed Off (4)Violation (31)Special Inspection (20)
01/30/2024
Signed off — Alteration
Replace seven (7) Split ductless HVAC Systems and install a new Air Handler on 3rd floor
B00962343-I1
12/20/2023
Permit issued — Mechanical Systems
B00962343-I1-MS
12/13/2023
Filed — Alteration
Replace seven (7) Split ductless HVAC Systems and install a new Air Handler on 3rd floor
B00962343-I1
11/29/2023
Special inspection requirement — Energy Code Compliance Inspections
Steven Bendoraitis
11/29/2023
Special inspection requirement — HVAC-R and service water heating equipment
Steven Bendoraitis
11/29/2023
Special inspection requirement — Maintenance information
Steven Bendoraitis
11/29/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ABDALLAH ELCHERBINI
11/29/2023
Special inspection requirement — Tenant Protection Plan Compliance
ABDALLAH ELCHERBINI
11/29/2023
Special inspection requirement — HVAC-R and service water heating system controls
Steven Bendoraitis
11/29/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Steven Bendoraitis
11/14/2023
Special inspection requirement — Final
Steven Bendoraitis
11/14/2023
Special inspection requirement — Mechanical Systems
ABDALLAH ELCHERBINI
06/22/2023
Signed off — Alteration
Install (2) new low pressure gas boilers. No change in use, egress, or occupancy under this application.
B00419305-I1
06/21/2023
Signed off — Alteration
Remove gas pipe from ex. S.O. valves to chillers (chiller work under B00430074). Install new gas pipe from ex. valves and connect to (2) boilers filed under B00419305. Cap & remove water piping. No change in use egress occupancy under this application.
B00419341-I1
06/10/2022
Signed off — Alteration
B00430074-I1
06/03/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jon Colatrella
06/03/2022
Special inspection requirement — Mechanical Systems
Jon Colatrella
06/03/2022
Special inspection requirement — Final
Jon Colatrella
06/03/2022
Special inspection requirement — HVAC insulation and sealing
Jon Colatrella
06/03/2022
Special inspection requirement — Electrical motors
Jon Colatrella
05/24/2022
Filed — Alteration
B00430074-P1
05/17/2021
Special inspection requirement — HVAC and service water heating equipment
Brad Cohen
05/17/2021
Special inspection requirement — Maintenance information
Brad Cohen
05/17/2021
Special inspection requirement — HVAC and service water heating system controls
Brad Cohen
05/13/2021
Filed — Alteration
Install (2) new low pressure gas boilers. No change in use, egress, or occupancy under this application.
B00419305-P1
05/13/2021
Filed — Alteration
Remove gas pipe from ex. S.O. valves to chillers (chiller work under B00430074). Install new gas pipe from ex. valves and connect to (2) boilers filed under B00419305. Cap & remove water piping. No change in use egress occupancy under this application.
B00419341-P1
05/06/2021
Special inspection requirement — Maintenance information
Brad Cohen
05/06/2021
Special inspection requirement — HVAC and service water heating system controls
Brad Cohen
05/06/2021
Special inspection requirement — HVAC and service water heating equipment
Brad Cohen
03/22/2021
Permit issued — Mechanical Systems
B00430074-I1-MS
12/10/2020
Permit issued — Boiler Equipment
B00419305-I1-BE
12/09/2020
Permit issued — Plumbing
B00419341-I1-PL
12/07/2020
Filed — Alteration
Install (2) new low pressure gas boilers. No change in use, egress, or occupancy under this application.
B00419305-I1
12/07/2020
Filed — Alteration
Remove gas pipe from ex. S.O. valves to chillers (chiller work under B00430074). Install new gas pipe from ex. valves and connect to (2) boilers filed under B00419305. Cap & remove water piping. No change in use egress occupancy under this application.
B00419341-I1
12/07/2020
Filed — Alteration
B00430074-I1
12/07/2020
Filed — Alteration
B00430071-I1
09/06/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/19/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/02/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/02/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/02/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/02/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/02/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/01/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/01/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/15/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/01/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/04/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
11/14/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
11/09/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/19/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/08/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/17/2000
Violation issued (ECB, closed)
Elevators
11/08/2000
Violation issued (ECB, closed)
Elevators
03/10/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/22/1999
Violation issued (ECB, closed)
Elevators
01/20/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Latest 60 of 67 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offCRAINE AIR CONDITIONING I12/20/2023
DOB NOWMechanical SystemsSigned-offALED TECHNOLOGIES INC03/22/2021
DOB NOWBoiler EquipmentSigned-offBONDEE ENTERPRISES INC12/10/2020
DOB NOWPlumbingSigned-offBONDEE ENTERPRISES INC12/09/2020
BISOTISSUEDRANSHAW PLUMBING & HEATIN12/11/2020
BISMHISSUEDG & E MECHANICAL CORP12/21/2009
BISFPISSUEDLUND FIRE PRODUCTS CO INC06/01/2004
BISPLISSUEDJ.E.S. PLBG & HTG CORP01/31/2001
BISBLRE-ISSUEDJ.E.S. PLBG & HTG CORP01/24/2001
BISSDISSUEDJ.E.S. PLBG & HTG CORP01/24/2001
BISSDISSUEDJ.E.S. PLBG & HTG CORP10/23/2000
BISPLISSUEDJ.E.S. PLBG & HTG CORP09/21/1999
BISFPISSUEDFIRE COMMAND CO., INC.09/08/1999
BIS—ISSUEDFRANK CORIGLIANO CONTRACTING INC08/10/1999
BIS—ISSUEDFRANK CORIGLIANO CONTRACTING INC04/01/1999
BISFPISSUEDSAFETY CONSULTANTS INC01/19/1993
2 projects · most recent 03/26/2020
General Wiring
FiledStatusContractorScope
03/26/2020CompleteALL CITY ELECTL CONTS INCGeneral Wiring
12/07/2018CompleteWILLDAN ELECTRICAL OF NYGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 20
DateRequirementInspectorRole
11/29/2023Energy Code Compliance InspectionsSteven Bendoraitisprogress
11/29/2023HVAC-R and service water heating equipmentSteven Bendoraitisenergy_progress
11/29/2023Maintenance informationSteven Bendoraitisenergy_progress
11/29/2023Fire-Resistant Penetrations and JointsABDALLAH ELCHERBINIspecial
11/29/2023Tenant Protection Plan ComplianceABDALLAH ELCHERBINIspecial
11/29/2023HVAC-R and service water heating system controlsSteven Bendoraitisenergy_progress
11/29/2023HVAC-R and service water piping design and insulationSteven Bendoraitisenergy_progress
11/14/2023FinalSteven Bendoraitisprogress
11/14/2023Mechanical SystemsABDALLAH ELCHERBINIspecial
06/03/2022Fire-Resistant Penetrations and JointsJon Colatrellaspecial
06/03/2022Mechanical SystemsJon Colatrellaspecial
06/03/2022FinalJon Colatrellaprogress
06/03/2022HVAC insulation and sealing Jon Colatrellaenergy_progress
06/03/2022Electrical motorsJon Colatrellaenergy_progress
05/17/2021HVAC and service water heating equipment Brad Cohenenergy_progress
05/17/2021Maintenance informationBrad Cohenenergy_progress
05/17/2021HVAC and service water heating system controls Brad Cohenenergy_progress
05/06/2021Maintenance informationBrad Cohenenergy_progress
05/06/2021HVAC and service water heating system controls Brad Cohenenergy_progress
05/06/2021HVAC and service water heating equipment Brad Cohenenergy_progress
▾Documents — 82 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch - Plumbing3
09/02/2026B00430071-I1Request digital key ↗
09/02/2026B00419341-I1Request digital key ↗
09/02/2026B00419341-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems2
09/02/2026B00430074-P1Request digital key ↗
09/02/2026B00430074-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Boiler Equipment2
09/02/2026B00419305-P1Request digital key ↗
09/02/2026B00419305-I1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/26/2026B00962343-I1Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION2
12/10/2020340795358Open ↗
12/22/2009320103124Open ↗
▸BISWORK PERMIT APPLICATION2
12/11/2020340795358Open ↗
12/22/2009320103124Open ↗
▸Seals & Professional Certifications34
▸DOB NOWProgress Inspector Seal & Signature15
09/23/2026B00419305-I1Open ↗
09/23/2026B00419305-I1Open ↗
09/23/2026B00419305-I1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
09/02/2026B00419305-I1Open ↗
09/02/2026B00419305-P1Open ↗
09/02/2026B00430074-I1Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
02/02/2010320103124Open ↗
12/22/2009320103124Open ↗
12/22/2009320103124Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026B00430074-I1Open ↗
09/01/2026B00430074-I1Open ↗
08/22/2026B00962343-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
12/10/2020340795358Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
12/22/2009320103124Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
12/10/2020340795358Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
12/22/2009320103124Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
12/10/2020340795358Open ↗
▸Trade Schedules & Equipment2
▸BISEQUIPMENT USE APPLICATION/PERMIT1
02/02/2010320103124Open ↗
▸BISEQUIPMENT USE PERMITS1
02/08/2010320103124Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
09/02/2026B00419305-I1Open ↗
09/02/2026B00419305-P1Open ↗
09/02/2026B00430074-I1Open ↗
Showing 3 of 8 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
12/22/2009320103124Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/10/2020340795358Open ↗
▸Energy Compliance3
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
06/22/2023340795358Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
12/10/2020340795358Open ↗
▸DOB NOWPreliminary Commissioning Report Certification1
09/02/2026B00419305-I1Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
06/29/2023340795358Open ↗
06/27/2023340795358Open ↗
06/26/2023340795358Open ↗
▸Approvals, Objections & Sign-offs12
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter8
09/02/2026B00419305-I1Open ↗
09/02/2026B00419305-P1Open ↗
09/02/2026B00430074-P1Open ↗
Showing 3 of 8 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
08/28/2023340795358Open ↗
02/02/2010320103124Open ↗
▸BISFINAL1
06/22/2023340795358Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
12/22/2009320103124Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT3
12/10/2020340795358Open ↗
02/02/2010320103124Open ↗
12/22/2009320103124Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
06/22/2023340795358Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
12/22/2009320103124Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
12/10/2020340795358Open ↗