← Back
Elevator apt, miscellaneous
311 EAST 72 STREET
💬 Discuss this project
1929Year Built
17Stories
D9Building Class
R10AZoning
121,234 sfGross Floor Area
131Units
LL97 CoveredRent Stabilized17 Open Violations ▸FISP: UNSAFE
Elevator apt, miscellaneous · 11,749 sf lot · 10.32 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbingFire ProtectionEquipmentCivilGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction1p · 1 filing · 14 docs
Cellar4p · 1 filing · 15 docs
Site & exteriorUnder Construction21p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PLATINUM SERVICES NY2809/29/2026
81 REALTY1203/21/2026
EIGHTY ONE REALTY1103/21/2026
81 REALTY CO C O THE ALPERT OFFC303/21/2026
311 REALTY CORP103/21/2026
PARCEL 242 CO C/O THE ALPERT OFC103/21/2026
PARCEL 242 CO C O THE ALPERT OFC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOORE ASSOCIATES, LLC310/01/2025
ASHRAF CORP504/30/2025
MSM ENGINEERING SERVICES, PLLC110/09/2024
G.R.E.E.N.209/18/2024
ROGER DE ELECTRIC CO.206/07/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
E-Z SAFETY NY403/21/2026
SALAMON ENGINEERING PLLC403/21/2026
KD DESIGNS303/21/2026
PLATINUM SERVICES NY203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PLATINUM SERVICES NY LLCGeneral Contractor1809/29/2026
BULADO GENERAL CONTRACTORGeneral Contractor308/18/2026
ADVANCED PLBG, MECH & SPRFire Protection207/08/2026
KONE ELEVATORSElectrical103/21/2026
MURPHY, DANIELElectrical103/21/2026
FORD, GUYElectrical103/21/2026
ADVANCED PLUMBING MECHPlumbing107/08/2026
GELLIS, IRWINElectrical103/21/2026
GUY FORDElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MOORE ASSOCIATES, LLC3408310/01/2025
O'ROURKE ENGINEERING, LLC5873310/01/2025
SALAMON ENGINEERING PLLC1264206/07/2024
CITY SAFETY COMPLIANCE CO8919107/12/2023
Building Lifecycle
All (138)Filed (15)Permit Issued (21)Facade (FISP) (15)Violation (60)Inspection (7)Objection (8)Special Inspection (12)
09/28/2026
Permit issued — Protection and Mechanical Methods
M01123751-I1-PMM
08/20/2026
Violation issued (HPD, open)
C
08/17/2026
Permit issued — General Construction
M00897033-I1-GC
06/18/2026
Permit issued — Suspended Scaffold
M01411876-I1-SC
06/04/2026
Filed — Alteration
MATERIAL HOIST. FOR MATERIALS ONLY. NO WORK FROM HOIST.
M01411876-I1
05/19/2026
Violation issued (HPD, open)
B
05/19/2026
Violation issued (HPD, open)
A
05/19/2026
Violation issued (HPD, closed)
B
05/15/2026
Violation issued (ECB, closed)
Unknown
05/15/2026
Violation issued (ECB, closed)
Unknown
05/08/2026
Cycle 10 facade report submitted
04/23/2026
Permit issued — Suspended Scaffold
M00897033-S1-SC
04/23/2026
Cycle 10 facade inspection completed
04/23/2026
Cycle 10 facade report signed — UNSAFE
04/13/2026
Filed — Alteration
FACADE RESTORATION, INSPECTIONS
M00897033-S1
10/21/2025
Objection resolved — Addressed
10/08/2025
Objection raised — Plumbing
10/07/2025
Permit issued — Protection and Mechanical Methods
M01123751-I1-PMM
10/07/2025
Permit issued — Supported Scaffold
M01123749-I1-SF
10/01/2025
Filed — Alteration
INSTALL 10 CLOTHES WASHER MACHINES, 10 ELECTRIC CLOTHES DRYERS WITH VENTING, WATER AND WASTE WATER PIPING, THREE SPRINKLER HEADS OFF EXISTING WET STANDPIPE. NO CHANGE IN EGREE, USE OR OCUPANCY.
M07997643-P2
09/16/2025
Permit issued — General Construction
M00897033-I1-GC
09/15/2025
Permit issued — Sidewalk Shed
M00647040-I1-SH
09/12/2025
Violation issued (ECB, closed)
Construction
07/17/2025
Permit issued — Suspended Scaffold
M01068416-I1-SC
05/21/2025
Permit issued — Suspended Scaffold
M01068416-I1-SC
04/30/2025
Filed — Alteration
INSTALLATION OF 300 psf SIDEWALK SHED AS PER PLANS, SIDEWALK SHED SHALL COMPLY WITH THE CHAPTER # 33 OF THE CODE 2014, NO CHANGES IN USE EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M00647040-P3
10/16/2024
Permit issued — General Construction
M00897033-I1-GC
10/09/2024
Filed — Alteration
M01123751-I1
10/09/2024
Filed — Alteration
INSTALLATION OF PIPE SCAFFOLDING AS PER PLANS. PIPE SCAFFOLDING SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE 2022. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M01123749-I1
10/09/2024
Permit issued — Protection and Mechanical Methods
M01123751-I1-PMM
10/09/2024
Permit issued — Supported Scaffold
M01123749-I1-SF
10/08/2024
Filed — Alteration
INSTALLATION OF 300 psf SIDEWALK SHED AS PER PLANS, SIDEWALK SHED SHALL COMPLY WITH THE CHAPTER # 33 OF THE CODE 2014, NO CHANGES IN USE EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
M00647040-P2
09/30/2024
Violation issued (HPD, open)
B
09/24/2024
Permit issued — Sidewalk Shed
M00647040-I1-SH
09/18/2024
Filed — Alteration
FACADE RESTORATION, INSPECTIONS
M01068416-P1
09/12/2024
Violation issued (HPD, open)
B
08/02/2024
Violation issued (HPD, open)
B
08/02/2024
Violation issued (HPD, open)
B
06/24/2024
Permit issued — Suspended Scaffold
M01068416-I1-SC
06/19/2024
Filed — Alteration
FACADE RESTORATION, INSPECTIONS
M01068416-I1
06/18/2024
Special inspection requirement — Masonry
David Salamon
06/18/2024
Special inspection requirement — Final
David Salamon
06/18/2024
Special inspection requirement — Tenant Protection Plan Compliance
EUGENIA MASUCCI
06/12/2024
Objection raised — Scope
06/12/2024
Objection resolved — Addressed
06/07/2024
Filed — Alteration
FACADE RESTORATION, INSPECTIONS
M00897033-P1
06/07/2024
Special inspection requirement — Masonry
David Salamon
06/07/2024
Special inspection requirement — Tenant Protection Plan Compliance
06/07/2024
Special inspection requirement — Final
David Salamon
10/04/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/27/2023
Permit issued — Sidewalk Shed
M00647040-I1-SH
07/18/2023
Objection resolved — Addressed
07/18/2023
Objection resolved — Addressed
07/17/2023
Objection raised — Inspections
07/17/2023
Objection raised — Structural
07/12/2023
Filed — Alteration
FACADE RESTORATION, INSPECTIONS
M00897033-I1
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/24/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
JAMES MOORE
Latest 60 of 138 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWProtection and Mechanical MethodsPermit IssuedPLATINUM SERVICES NY LLC09/28/2026
DOB NOWGeneral ConstructionPermit IssuedBULADO GENERAL CONTRACTOR08/17/2026
DOB NOWSuspended ScaffoldSigned-offROSENWACH TANK CO.,LLC06/18/2026
DOB NOWSuspended ScaffoldSigned-offBULADO GENERAL CONTRACTOR04/23/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedPLATINUM SERVICES NY LLC10/07/2025
DOB NOWSupported ScaffoldPermit IssuedPLATINUM SERVICES NY LLC10/07/2025
DOB NOWGeneral ConstructionPermit IssuedBULADO GENERAL CONTRACTOR09/16/2025
DOB NOWSidewalk ShedPermit IssuedPLATINUM SERVICES NY LLC09/15/2025
DOB NOWSuspended ScaffoldPermit IssuedBULADO GENERAL CONTRACTOR07/17/2025
DOB NOWSuspended ScaffoldPermit IssuedBULADO GENERAL CONTRACTOR05/21/2025
DOB NOWGeneral ConstructionPermit IssuedBULADO GENERAL CONTRACTOR10/16/2024
DOB NOWProtection and Mechanical MethodsPermit IssuedPLATINUM SERVICES NY LLC10/09/2024
DOB NOWSupported ScaffoldPermit IssuedPLATINUM SERVICES NY LLC10/09/2024
DOB NOWSidewalk ShedPermit IssuedPLATINUM SERVICES NY LLC09/24/2024
DOB NOWSuspended ScaffoldPermit IssuedBULADO GENERAL CONTRACTOR06/24/2024
DOB NOWSidewalk ShedPermit IssuedPLATINUM SERVICES NY LLC09/27/2023
DOB NOWSprinklersPermit IssuedADVANCED PLBG, MECH & SPR01/24/2023
DOB NOWStandpipePermit IssuedADVANCED PLUMBING MECH01/24/2023
DOB NOWSidewalk ShedPermit IssuedPLATINUM SERVICES NY LLC01/24/2023
DOB NOWStandpipePermit IssuedADVANCED PLBG, MECH & SPR01/24/2023
DOB NOWSidewalk ShedPermit IssuedPLATINUM SERVICES NY LLC12/16/2021
BISOTISSUEDBULADO GENERAL CONTRACTOR08/09/2016
BISPLISSUEDBELL FUEL OIL, LLC05/05/2016
BISEQISSUEDROCKLEDGE SCAFFOLD CORP03/09/2016
BISFSISSUEDABILENE, INC11/30/2015
BISOTISSUEDMAXWELL PLUMB MECH CORP09/18/2015
BISPLISSUEDMAXWELL PLUMB MECH. CORP09/18/2015
BISFBISSUEDABILENE, INC08/21/2015
BISOTISSUEDABILENE INC04/23/2015
BISPLISSUEDBELL FUEL OIL, LLC04/23/2015
BISEQISSUEDROCKLEDGE SCAFFOLD CORP03/15/2013
BISOTISSUEDBULADO GENERAL CONTRACTOR03/15/2013
BISEQISSUEDROCKLEDGE SCAFFOLD CORP10/01/2012
BISSDISSUEDLOTUS PLUMBING ,HEATING02/06/2001
BISEQISSUEDFRANCO REMODELING CORP07/31/2000
BISEQISSUEDSPRING ENTERPRIS INC.07/24/2000
1 project · most recent 10/01/2025
FiledStatusContractorScope
10/01/2025Permit IssuedADVANCED PLBG, MECH & SPR3 heads, 1 outlets
1 project · most recent 10/01/2025
Gas Water/Sanitary
FiledStatusContractorScope
10/01/2025Permit IssuedADVANCED P,MECH & SPR CORGas, Water/Sanitary
4 projects · most recent 07/14/2026
General Wiring
FiledStatusContractorScope
07/14/2026Permit IssuedRICHARD NEU—
03/09/2022Permit IssuedIRWIN ELECTR'L CONTR'S, IGeneral Wiring
03/09/2022Permit IssuedIRWIN ELECTR'L CONTR'S, IGeneral Wiring
12/13/2021CompleteILLUMINOUS ELECTRIC CORP.General Wiring
2 projects · most recent 04/30/2025
Sidewalk Shed Scaffold
FiledStatusContractorScope
04/30/2025Permit IssuedPLATINUM SERVICES NY LLCSidewalk Shed
10/09/2024Permit IssuedPLATINUM SERVICES NY LLCScaffold
3 projects · most recent 06/04/2026
Suspended Scaffold (SC)
FiledStatusContractorScope
06/04/2026Signed-offROSENWACH TANK CO.,LLCSuspended Scaffold (SC)
04/13/2026Permit IssuedBULADO GENERAL CONTRACTORSuspended Scaffold (SC)
09/18/2024Permit IssuedBULADO GENERAL CONTRACTORSuspended Scaffold (SC)
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
03/23/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/23/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/23/2023Pass-Final SD - Up to 3 Requested FloorsPassView ↗
03/23/2023Pass-Final SP - Up to 3 Requested FloorsPassView ↗
03/20/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
03/20/2023Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
02/01/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
06/18/2024MasonryDavid Salamonspecial
06/18/2024FinalDavid Salamonprogress
06/18/2024Tenant Protection Plan ComplianceEUGENIA MASUCCIspecial
06/07/2024MasonryDavid Salamonspecial
06/07/2024Tenant Protection Plan Compliance—special
06/07/2024FinalDavid Salamonprogress
03/24/2023Fire-Resistant Penetrations and JointsJAMES MOOREspecial
03/24/2023Standpipe SystemsBRIAN O'ROURKEspecial
03/24/2023Sprinkler SystemsBRIAN O'ROURKEspecial
02/08/2023Fire-Resistant Penetrations and JointsJAMES MOOREspecial
02/08/2023Sprinkler SystemsBRIAN O'ROURKEspecial
02/08/2023Standpipe SystemsBRIAN O'ROURKEspecial
▾Documents — 178 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch15
08/26/2026M01068416-I1Request digital key ↗
08/26/2026M01068416-P1Request digital key ↗
08/26/2026M01123751-I1Request digital key ↗
Showing 3 of 15 on file for this type
▸Applications & Permits27
▸BISPLAN / WORK APPROVAL APPLICATION13
08/08/2016140526893Open ↗
08/05/2016122807061Open ↗
07/01/2016122807061Open ↗
Showing 3 of 13 on file for this type
▸BISWORK PERMIT APPLICATION13
10/13/2016122807061Open ↗
08/11/2016122807061Open ↗
03/08/2016140467402Open ↗
Showing 3 of 13 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
09/11/2015122218929Open ↗
▸Seals & Professional Certifications54
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION17
05/24/2017122807061Open ↗
04/11/2017140467402Open ↗
01/03/2017122807061Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature13
08/26/2026M01123751-I1Open ↗
08/24/2026M00647040-I1Open ↗
08/24/2026M00647040-P1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
08/28/2026M00897033-I1Open ↗
08/28/2026M00897033-I1Open ↗
08/25/2026M00897033-P1Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT4
08/08/2016140526893Open ↗
03/08/2016140467402Open ↗
05/04/2015122364351Open ↗
Showing 3 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION3
08/08/2016140526893Open ↗
03/08/2016140467402Open ↗
03/14/2013140062312Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
08/08/2016140526893Open ↗
03/08/2016140467402Open ↗
03/14/2013140062312Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
05/04/2015122364351Open ↗
10/01/2012121395784Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026M00897033-I1Open ↗
08/25/2026M00897033-P1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
10/01/2012121395784Open ↗
▸Trade Schedules & Equipment11
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE5
12/04/2015122218929Open ↗
11/30/2015122218929Open ↗
10/19/2015122218929Open ↗
Showing 3 of 5 on file for this type
▸BISSELF-CERT PLUMBING NOTICE4
12/21/2015122218929Open ↗
12/21/2015122218929Open ↗
11/16/2015122218929Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
05/04/2015122364351Open ↗
05/04/2015122364351Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
07/01/2016122807061Open ↗
▸Environmental & Asbestos11
▸BISASBESTOS: CERTIFICATION (DEP ACP5)6
09/11/2015122218929Open ↗
09/11/2015122218929Open ↗
05/04/2015122364351Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/21/2026M07997643-P1Open ↗
08/21/2026M07997643-P2Open ↗
08/21/2026M07997643-I1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance13
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS7
07/20/2016122364351Open ↗
07/01/2016122807061Open ↗
06/10/2016122364351Open ↗
Showing 3 of 7 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS4
07/20/2016122364351Open ↗
06/10/2016122364351Open ↗
01/19/2016122218929Open ↗
Showing 3 of 4 on file for this type
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
03/08/2016140467402Open ↗
▸BISTR8: Energy Code Progress Inspections1
03/18/2013121424823Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
03/08/2016140467402Open ↗
03/14/2013140062312Open ↗
▸Approvals, Objections & Sign-offs17
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST11
05/24/2017122807061Open ↗
04/11/2017140467402Open ↗
01/03/2017122807061Open ↗
Showing 3 of 11 on file for this type
▸BISADMINISTRATIVE OBJECTIONS2
11/14/2012121424823Open ↗
10/01/2012121395784Open ↗
▸BISCCD1-Construction Code Determination2
07/30/2013121424823Open ↗
02/25/2013121424823Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
07/20/2016122364351Open ↗
▸BISLETTERS - APPROVED FABRICATION CERTIFICATIONS1
04/23/2013121424823Open ↗
▸Cost, Insurance & Ownership10
▸BISCOST AFFIDAVIT10
12/13/2016122807061Open ↗
08/08/2016140526893Open ↗
07/20/2016122364351Open ↗
Showing 3 of 10 on file for this type
▸Filing & Intake Forms9
▸BISEFILING COVER SHEET4
07/01/2016122807061Open ↗
09/11/2015122218929Open ↗
05/04/2015122364351Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET4
08/08/2016140526893Open ↗
03/08/2016140467402Open ↗
03/14/2013140062312Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION1
11/10/2015122364351Open ↗
▸Other Documents8
▸DOB NOWCalculations4
08/16/2026M01411876-I1Open ↗
08/13/2026M00897033-S1Open ↗
08/13/2026M01068416-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWManufacturer's Specifications4
08/16/2026M01411876-I1Open ↗
08/13/2026M00897033-S1Open ↗
08/13/2026M01068416-P1Open ↗
Showing 3 of 4 on file for this type