| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 01/21/2022 | $2.2M | — | Private party → Private party | $611/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| NEW YORK ENGINEERS LLC | 8 | 01/16/2025 |
| ARCHETYPE ARCHITECTURE | 3 | 08/22/2024 |
| CRAFT ENGINEERING STUDIO PLLC | 2 | 06/21/2023 |
| STRUCTURES & FOUNDATIONS PC | 1 | 06/13/2023 |
| JOSH MANES ARCHITECTURE, DPC | 1 | 05/03/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| JENNY FLORES EXPEDITING | 14 | 03/21/2026 |
| KX CONSULTING | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| DESIGN SMART NYC INC | General Contractor | 14 | 07/08/2026 |
| ALEXANDRE NOSSOULENKO | Electrical | 10 | 03/21/2026 |
| NONSTOP PLUMBERS CORP | Fire Protection | 2 | 07/08/2026 |
| AUTHENTIC PLBG CORP | Plumbing | 2 | 07/08/2026 |
| KENNEDY CONSTRUCTION SERV | General Contractor | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| AR ARCHITECT P.C. | 1171 | 6 | 01/16/2025 |
| NORMAN C. LOK | 818 | 5 | 12/30/2024 |
| STRUCTURES & FOUNDATIONS | 7714 | 1 | 06/13/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Sprinklers | Signed-off | NONSTOP PLUMBERS CORP | 11/18/2024 |
| DOB NOW | General Construction | Permit Issued | DESIGN SMART NYC INC | 11/18/2024 |
| DOB NOW | Mechanical Systems | Permit Issued | DESIGN SMART NYC INC | 11/18/2024 |
| DOB NOW | Sprinklers | Signed-off | AUTHENTIC PLBG CORP | 11/18/2024 |
| DOB NOW | Construction Fence | Signed-off | DESIGN SMART NYC INC | 05/24/2024 |
| DOB NOW | Support of Excavation | Signed-off | DESIGN SMART NYC INC | 04/02/2024 |
| DOB NOW | Foundation | Signed-off | DESIGN SMART NYC INC | 03/28/2024 |
| DOB NOW | General Construction | Permit Issued | DESIGN SMART NYC INC | 11/14/2023 |
| DOB NOW | Plumbing | Signed-off | AUTHENTIC PLBG CORP | 10/26/2023 |
| DOB NOW | Structural | Signed-off | DESIGN SMART NYC INC | 10/26/2023 |
| DOB NOW | Sprinklers | Signed-off | NONSTOP PLUMBERS CORP | 10/26/2023 |
| DOB NOW | Mechanical Systems | Permit Issued | DESIGN SMART NYC INC | 10/24/2023 |
| DOB NOW | Construction Fence | Signed-off | DESIGN SMART NYC INC | 06/20/2023 |
| DOB NOW | General Construction | Signed-off | DESIGN SMART NYC INC | 06/06/2023 |
| DOB NOW | General Construction | Signed-off | KENNEDY CONSTRUCTION SERV | 05/08/2023 |
| BIS | OT | ISSUED | CARICIC CONSTRUCTION INC | 07/03/2019 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| — | — | — | Heating and Air Conditioning Systems | Heat / Cool Daikin FXSQ15TAVJU 15,000 BTU · Vrf Indoor ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| — | — | — | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/04/2025 | Complete | SD ELECTL DIVISION NYC CO | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 01/21/2025 | Certified Storm Drainage-ST-Fixtures-Finish | Certified | View ↗ |
| 01/21/2025 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 01/20/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 01/17/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 01/17/2025 | Pass-Final SP - Up to 3 Requested Floors | Pass | View ↗ |
| 12/02/2024 | Pass-Final SP - Up to 3 Requested Floors | Pass | View ↗ |
| 05/15/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 05/02/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 01/27/2025 | Fire-Resistant Penetrations and Joints | ANGEL ROJAS | special |
| 01/27/2025 | Mechanical Systems | ANGEL ROJAS | special |
| 01/27/2025 | Post-installed Anchors | ANGEL ROJAS | special |
| 01/27/2025 | Shutoff dampers | ANGEL ROJAS | energy_progress |
| 01/27/2025 | Maintenance information | ANGEL ROJAS | energy_progress |
| 01/27/2025 | HVAC-R and service water heating equipment | ANGEL ROJAS | energy_progress |
| 01/27/2025 | HVAC-R and service water piping design and insulation | ANGEL ROJAS | energy_progress |
| 01/27/2025 | HVAC-R and service water heating system controls | ANGEL ROJAS | energy_progress |
| 01/27/2025 | Duct leakage testing, insulation and design | — | energy_progress |
| 01/27/2025 | Energy Code Compliance Inspections | ANGEL ROJAS | progress |
| 01/27/2025 | Final | ANGEL ROJAS | progress |
| 12/27/2024 | Sprinkler Systems | NORMAN LOK | special |
| 11/26/2024 | Lighting controls | — | energy_progress |
| 08/21/2024 | Lighting in dwelling units | ANGEL ROJAS | energy_progress |
| 08/21/2024 | Fenestration air leakage | ANGEL ROJAS | energy_progress |
| 08/21/2024 | Energy Code Compliance Inspections | ANGEL ROJAS | progress |
| 08/21/2024 | Fenestration and door U-factor and product ratings | ANGEL ROJAS | energy_progress |
| 08/21/2024 | Fire-Resistant Penetrations and Joints | ANGEL ROJAS | special |
| 06/27/2024 | Mechanical Systems | ANGEL ROJAS | special |
| 06/27/2024 | Post-installed Anchors | ANGEL ROJAS | special |
| 06/27/2024 | Energy Code Compliance Inspections | ANGEL ROJAS | progress |
| 06/27/2024 | Final | ANGEL ROJAS | progress |
| 06/27/2024 | HVAC-R and service water piping design and insulation | ANGEL ROJAS | energy_progress |
| 06/27/2024 | Duct leakage testing, insulation and design | — | energy_progress |
| 06/27/2024 | HVAC-R and service water heating equipment | ANGEL ROJAS | energy_progress |