← Back
Two family brick
3141 KINGSLAND AVENUE
BRONX · Eastchester-Edenwald-Baychester · BIN 2114000
💬 Discuss this project
2005Year Built
2Stories
B1Building Class
R4-1Zoning
—Gross Floor Area
2Units
2 Open Violations ▸FDNY Report ↗
Two family brick · 1.3 FAR built · Flood zone X
Locations of Work
ArchitectureGeneral
Filed — no permit issued2p · 1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MARYLOU DEVELOPMENT103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC103/12/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854103/12/2026
Building Lifecycle
All (11)Filed (1)Violation (4)Objection (1)Special Inspection (5)
03/17/2026
Objection raised — Admin
03/12/2026
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONIC GENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEING APPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
X01367469-I1
03/12/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
03/12/2026
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
03/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
03/04/2026
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
03/04/2026
Special inspection requirement — Final
TOM PETERSEN
01/19/2023
Violation issued (HPD, closed)
C
01/19/2023
Violation issued (HPD, open)
C
01/19/2023
Violation issued (HPD, open)
A
01/26/2006
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDCENTURION SOLAR ENERGY10/17/2023
BISOTISSUEDNYS ESSENTIAL POWER INC08/07/2023
BIS—ISSUEDMARILOU DEVELOPMENT CO. INC.03/21/2006
BISEQISSUEDMARILOU DEVELOPMENT CO. INC.03/16/2006
BISEQISSUEDMARILOU DEVELOPMENT CO. INC.05/24/2005
1 project · most recent 09/05/2023
FiledStatusContractorScope
09/05/2023CompleteBERGER QUALITY ELEC'L CON—
1 project · most recent 03/12/2026
FiledStatusContractorScope
03/12/2026——56 panels, 20.44 kw, 539.16 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/12/2026Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
03/12/2026Air barrier - visual inspectionTOM PETERSENenergy_progress
03/04/2026Fire-Resistant Penetrations and JointsTOM PETERSENspecial
03/04/2026Energy Code Compliance InspectionsTOM PETERSENprogress
03/04/2026FinalTOM PETERSENprogress
▾Documents — 41 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/17/2026X01367469-I1Request digital key ↗
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION3
04/03/2024240354013Open ↗
09/12/2023240354013Open ↗
07/30/2023240351800Open ↗
▸BISWORK PERMIT APPLICATION2
10/17/2023240354013Open ↗
08/07/2023240351800Open ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature3
08/30/2026X01367469-I1Open ↗
08/30/2026X01367469-I1Open ↗
08/30/2026X01367469-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE2
09/12/2023240354013Open ↗
07/30/2023240351800Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/30/2026X01367469-I1Open ↗
08/30/2026X01367469-I1Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/30/2023240351800Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/17/2026X01367469-I1Open ↗
▸Safety & Tenant Protection2
▸BISTPP1: TENANT PROTECTION PLAN2
09/12/2023240354013Open ↗
08/07/2023240351800Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/30/2023240351800Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/17/2026X01367469-I1Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
09/12/2023240354013Open ↗
09/12/2023240354013Open ↗
07/30/2023240351800Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)2
09/12/2023240354013Open ↗
07/30/2023240351800Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
07/30/2023240351800Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
08/07/2023240351800Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
08/07/2023240351800Open ↗
▸Inspections & Test Reports7
▸BISTECHNICAL REPORT: RESPONSIBILITY4
09/12/2023240354013Open ↗
09/12/2023240354013Open ↗
09/12/2023240354013Open ↗
Showing 3 of 4 on file for this type
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
08/07/2023240351800Open ↗
▸BISDIR-14 ID OF RESPONSIBILITY (TR1)1
08/07/2023240351800Open ↗
▸BISSTRUCTURAL STABILITY - ALTERATIONS OF EXISTING BUILDINGS1
08/07/2023240351800Open ↗
▸Approvals, Objections & Sign-offs1
▸BISFINAL1
08/07/2023240351800Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
09/12/2023240354013Open ↗
07/30/2023240351800Open ↗
▸Filing & Intake Forms3
▸BISEFILING JOB APPLICATION COVER SHEET2
09/12/2023240354013Open ↗
07/30/2023240351800Open ↗
▸BISADDITIONAL INFORMATION1
04/03/2024240354013Open ↗
▸Other Documents1
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
09/12/2023240354013Open ↗