| Owner | Filings | Most Recent |
|---|---|---|
| WEBSTER 204 REALTY | 2 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 07/29/2020 | $1.2M | — | ALBANY CRESCENT HOLDING LLC → BAILEY DEVELOPMENT LLC | $912/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| BEST ENGINEERING TECHNOLOGY DESIGN | 8 | 10/02/2024 |
| SHARON ENGINEERING, P.C | 6 | 09/03/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| BEST ENGINEERING | 12 | 03/21/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| BIS | — | ISSUED | RJ STAHL ARCHITECT, PC | 01/25/2019 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 10/02/2024 | — | — | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Daikin 3MXS24NMVJU 24,000 BTU · Condensing Unit ×20 4MXS36NMVJU 36,000 BTU · Condensing Unit ×12 RMXS48LVJU 48,000 BTU · Condensing Unit ×1 Heating Daikin 3MXS24NMVJU 24,000 BTU · Heat Pump Outdoor ×20 4MXS36NMVJU 36,000 BTU · Heat Pump Outdoor ×12 RMSX48LVJU 54,000 BTU · Vrf Outdoor ×1 Ventilation Broan ×55 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/02/2024 | — | — | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/02/2024 | — | — | Steel, Concrete |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/02/2024 | — | — | Fence |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 12/26/2024 | Mechanical Systems | — | special |
| 12/26/2024 | Final | — | progress |
| 12/26/2024 | HVAC-R and service water heating equipment | — | energy_progress |
| 12/26/2024 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 12/26/2024 | Shutoff dampers | — | energy_progress |
| 12/26/2024 | HVAC-R and service water heating system controls | — | energy_progress |
| 09/18/2024 | Final | — | progress |
| 09/18/2024 | Footing and Foundation | — | progress |
| 09/18/2024 | Subsurface Investigations (Borings/Test Pits) | — | special |
| 09/18/2024 | Subsurface Conditions – Fill Placement & In-Place Density | — | special |
| 09/18/2024 | Post-installed Anchors | — | special |
| 09/18/2024 | Subgrade Inspections | — | special |
| 09/18/2024 | Concrete - Cast-In-Place | — | special |
| 08/09/2024 | Subsurface Investigations (Borings/Test Pits) | — | special |
| 08/09/2024 | Fire-Resistant Penetrations and Joints | — | special |
| 08/09/2024 | Footing and Foundation | — | progress |
| 08/09/2024 | Final | — | progress |
| 08/09/2024 | On-Site Private Sewage Disposal Systems Installation | — | special |
| 08/09/2024 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | — | special |
| 08/09/2024 | Energy Code Compliance Inspections | — | progress |
| 08/09/2024 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 08/09/2024 | Metering | — | energy_progress |
| 08/09/2024 | HVAC-R and service water heating system controls | — | energy_progress |
| 08/09/2024 | Maintenance information | — | energy_progress |
| 08/09/2024 | HVAC-R and service water heating equipment | — | energy_progress |