← Back
Primarily 3 family with 1 store or office
315 7 AVENUE
BROOKLYN · BIN 3025853
💬 Discuss this project
1888Year Built
4Stories
S3Building Class
R6AZoning
5,440 sfGross Floor Area
4Units
Rent Stabilized3 Open Violations 2 unresolved · 1 paperwork only ▸FDNY Report ↗
Primarily 3 family with 1 store or office · Owner of record: M & V PROPERTIES · 1,817 sf lot · 2.99 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction5p · 1 filing · 20 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
M V PROPERTIES303/22/2026
7TH AVE PARK SLOPE STATIONERS & COPY INC103/22/2026
C/O PHIL TANELLA (OWNERS REP)103/21/2026
C O PHIL TANELLA OWNERS REP103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
INGA CONSULTING ENGINEERS307/01/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LAVB DESIGN CONSULTANTS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
D'AMBROSIA, LENARDElectrical103/21/2026
KHAN, ROBERTElectrical103/21/2026
WILLDAN ELECTRICAL OF NYElectrical103/22/2026
ROBERT MICHAEL DESIGN & CGeneral Contractor104/09/2026
JNR PLUMBING INC DBAPlumbing107/04/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781307/01/2026
Building Lifecycle
All (54)Filed (3)Permit Issued (2)Violation (27)Inspection (7)Special Inspection (15)
07/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
07/02/2026
Special inspection requirement — Energy Code Compliance Inspections
Andrew Inga
07/02/2026
Special inspection requirement — HVAC-R and service water heating equipment
Andrew Inga
07/02/2026
Special inspection requirement — Maintenance information
Andrew Inga
07/02/2026
Special inspection requirement — HVAC-R and service water heating system controls
Andrew Inga
07/02/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Andrew Inga
07/01/2026
Filed — Alteration
HEREWITH FILING TO CAP AND REMOVE ALL EXISTING PLUMBING FIXTURES, ALONG WITH THE INSTALLATION OF ALL ELECTRIC PLUMBING FIXTURES AS PER PLANS FOR EXISTING APARTMENT #1 AT SECOND FLOOR NEW PLUMBING FIXTURES AS PER PLAN
B01233551-P1
05/06/2026
Special inspection requirement — Maintenance information
Andrew Inga
05/06/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Andrew Inga
05/06/2026
Special inspection requirement — HVAC-R and service water heating equipment
Andrew Inga
05/06/2026
Special inspection requirement — HVAC-R and service water heating system controls
Andrew Inga
05/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
05/06/2026
Special inspection requirement — Energy Code Compliance Inspections
Andrew Inga
02/18/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/13/2026
Permit issued — Plumbing
B01233551-S1-PL
01/30/2026
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
11/18/2025
Permit issued — General Construction
B01233551-I1-GC
10/31/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
10/31/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
10/31/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/31/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/28/2025
Filed — Alteration
HEREWITH FILING TO CAP AND REMOVE ALL EXISTING PLUMBING FIXTURES, ALONG WITH THE INSTALLATION OF ALL ELECTRIC PLUMBING FIXTURES AS PER PLANS FOR EXISTING APARTMENT #1 AT SECOND FLOOR NEW PLUMBING FIXTURES AS PER PLAN
B01233551-S1
10/16/2025
Filed — Alteration
HEREWITH FILING TO CAP AND REMOVE ALL EXISTING PLUMBING FIXTURES, ALONG WITH THE INSTALLATION OF ALL ELECTRIC PLUMBING FIXTURES AS PER PLANS FOR EXISTING APARTMENT #1 AT SECOND FLOOR NEW PLUMBING FIXTURES AS PER PLAN
B01233551-I1
05/29/2025
Special inspection requirement — Final
Andrew Inga
05/29/2025
Special inspection requirement — Energy Code Compliance Inspections
Andrew Inga
05/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
06/20/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/20/2022
Violation issued (HPD, open)
A
10/20/2022
Violation issued (HPD, closed)
B
10/20/2022
Violation issued (HPD, closed)
B
10/20/2022
Violation issued (HPD, closed)
B
10/20/2022
Violation issued (HPD, closed)
A
10/20/2022
Violation issued (HPD, closed)
B
10/20/2022
Violation issued (HPD, closed)
C
10/20/2022
Violation issued (HPD, open)
B
10/20/2022
Violation issued (HPD, closed)
C
10/20/2022
Violation issued (HPD, closed)
B
10/20/2022
Violation issued (HPD, closed)
B
10/20/2022
Violation issued (HPD, closed)
B
10/20/2022
Violation issued (HPD, closed)
B
10/20/2022
Violation issued (HPD, closed)
A
10/20/2022
Violation issued (HPD, closed)
A
10/20/2022
Violation issued (HPD, closed)
C
10/20/2022
Violation issued (HPD, closed)
B
10/20/2022
Violation issued (HPD, closed)
B
10/20/2022
Violation issued (HPD, closed)
B
10/20/2022
Violation issued (HPD, closed)
B
02/18/2022
Violation issued (HPD, closed)
A
04/05/2021
Violation issued (HPD, closed)
A
04/05/2021
Violation issued (HPD, closed)
I
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/02/1993
Violation issued (ECB, closed)
Construction
11/19/1991
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/21/1990
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedJNR PLUMBING INC DBA02/13/2026
DOB NOWGeneral ConstructionPermit IssuedROBERT MICHAEL DESIGN & C11/18/2025
BISPLISSUEDGAS APPROVED SERVICE CORP06/02/2017
BISOTISSUEDRESIDENTIAL RESTORATION S01/04/2017
BISFBISSUEDBAYSIDE FUEL08/02/2005
BIS—ISSUEDULTIMATE SIGNS & DESIGNS CORP.03/10/1992
1 project · most recent 07/01/2026
Gas Water/Sanitary
FiledStatusContractorScope
07/01/2026Permit IssuedJNR PLUMBING INC DBAGas, Water/Sanitary
1 project · most recent 03/04/2019
General Wiring
FiledStatusContractorScope
03/04/2019CompleteWILLDAN ELECTRICAL OF NYGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
02/18/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/30/2026Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
10/31/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
10/31/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
10/31/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/31/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/20/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
07/02/2026Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
07/02/2026Energy Code Compliance InspectionsAndrew Ingaprogress
07/02/2026HVAC-R and service water heating equipmentAndrew Ingaenergy_progress
07/02/2026Maintenance informationAndrew Ingaenergy_progress
07/02/2026HVAC-R and service water heating system controlsAndrew Ingaenergy_progress
07/02/2026HVAC-R and service water piping design and insulationAndrew Ingaenergy_progress
05/06/2026Maintenance informationAndrew Ingaenergy_progress
05/06/2026HVAC-R and service water piping design and insulationAndrew Ingaenergy_progress
05/06/2026HVAC-R and service water heating equipmentAndrew Ingaenergy_progress
05/06/2026HVAC-R and service water heating system controlsAndrew Ingaenergy_progress
05/06/2026Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
05/06/2026Energy Code Compliance InspectionsAndrew Ingaprogress
05/29/2025FinalAndrew Ingaprogress
05/29/2025Energy Code Compliance InspectionsAndrew Ingaprogress
05/29/2025Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/20/2026B01233551-S1Request digital key ↗
08/20/2026B01233551-P1Request digital key ↗
08/20/2026B01233551-I1Request digital key ↗
▸Applications & Permits6
▸DOB NOWLPC Approval/Permit3
08/20/2026B01233551-P1Open ↗
08/13/2026B01233551-S1Open ↗
08/13/2026B01233551-I1Open ↗
▸BISWORK PERMIT APPLICATION2
06/12/2017321500951Open ↗
01/05/2017321500951Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
12/29/2016321500951Open ↗
▸Seals & Professional Certifications14
▸DOB NOWProgress Inspector Seal & Signature5
08/27/2026B01233551-P1Open ↗
08/27/2026B01233551-P1Open ↗
08/24/2026B01233551-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/20/2026B01233551-P1Open ↗
08/13/2026B01233551-I1Open ↗
08/13/2026B01233551-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
08/27/2026B01233551-P1Open ↗
08/24/2026B01233551-I1Open ↗
08/23/2026B01233551-S1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
12/29/2016321500951Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
12/29/2016321500951Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
12/29/2016321500951Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
12/29/2016321500951Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
12/29/2016321500951Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/20/2026B01233551-P1Open ↗
08/13/2026B01233551-S1Open ↗
08/13/2026B01233551-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/29/2016321500951Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
12/29/2016321500951Open ↗
▸Approvals, Objections & Sign-offs1
▸BISLANDMARKS APPROVAL1
12/29/2016321500951Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
12/29/2016321500951Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
12/27/2016321500951Open ↗