← Back
Elevator apt, semi-fireproof without stores
3160 VILLA AVENUE
BRONX · BIN 2017331
💬 Discuss this project
2021Year Built
11Stories
D1Building Class
R8Zoning
49,563 sfGross Floor Area
66Units
LL97 CoveredRent Stabilized7 Open Violations ▸
Elevator apt, semi-fireproof without stores · Owner of record: 1 HOLLAND VILLA, LLC · 7,500 sf lot · 6.61 FAR built · Flood zone X
Locations of Work
StructuralMechanicalFire Protection
Roof4p · 3 filings · 16 docs
Floor 113p · 3 filings · 16 docs
Floor 101p · 2 filings · 4 docs
Floor 93p · 3 filings · 16 docs
Floor 82p · 3 filings · 16 docs
Floor 71p · 2 filings · 4 docs
Floor 61p · 2 filings · 4 docs
Floor 53p · 3 filings · 12 docs
Floor 41p · 2 filings · 4 docs
Floor 31p · 2 filings · 4 docs
Floor 23p · 3 filings · 16 docs
Floor 11p · 2 filings · 4 docs
Cellar1p · 2 filings · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
LAQUILA GROUP3207/08/2026
RELIABLE ENTERPRISES2003/22/2026
REPUBLIC EXTERIOR SERVICES1303/22/2026
PARTNER MICHAEL WALSH103/22/2026
CLASS ONE CONSTRUCTION303/22/2026
BRONX103/22/2026
1 HOLLAND403/21/2026
3160 VILLA AVENUE303/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/11/2019$959K—— → —— not available
06/28/2019$750K—Private party → 3160 VILLA AVENUE, LLC— not available
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PATUXENT ENGINEERING1203/21/2026
KATARIA BUILDERS403/21/2026
ARCOMETRIC DESIGN203/21/2026
A1 EXPEDITING SERVICE203/21/2026
T F CUSANELLI FILLETTI ARCHITECT203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RELIABLE ENTERPRISES INCGeneral Contractor1503/21/2026
CLASS ONE CONSTRUCTION LTGeneral Contractor1507/08/2026
REPUBLIC EXTERIOR SERVICEGeneral Contractor1007/08/2026
REPUBLIC SCAFFOLD&HOIST CGeneral Contractor603/21/2026
A & H INSTALLATION INCGeneral Contractor607/08/2026
SANO WRECKING LLCGeneral Contractor307/08/2026
ROCK E SMALL PLBG&HTG INCPlumbing203/22/2026
PRIME PIPING & HEATING INFire Protection207/08/2026
RICHARD NEUElectrical203/22/2026
WCK ELECTRIC CORP.Electrical103/22/2026
UNIVERSAL FIRE SPR LLCFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PATUXENT ENGINEERING, LLC1893505/01/2023
METRIC CONSULTING AND INS1803209/21/2020
Building Lifecycle
All (91)Filed (20)Permit Issued (28)Signed Off (9)Violation (4)Inspection (2)Objection (16)Special Inspection (12)
01/08/2025
Signed off — Alteration
X00826684-I1
01/08/2025
Signed off — Alteration
INSTALLATION OF SINGLE 6000 # CAPACITY PERSONNEL/MATERIAL HOIST DURING NB CONST, FILED SEP. HOIST SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. ELEVATOR APPLICATION SUBMITTED SEPARATELY
X00515701-I1
01/08/2025
Signed off — Alteration
X00492153-I1
11/13/2024
Signed off — Alteration
INSTALLATION OF CANTLIEVER BEAM SCAFFOLD DURING NEW BUILDING CONTRUCTION FOR WORKER ACCESS. CANTLIEVER BEAM SCAFFOLD IS DESIGNED IN ACCORDANCE WITH NYCC 2014 CHAPTER 33 BUILDING CODE. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
X00606783-I1
08/14/2024
Signed off — Alteration
X00545227-I1
02/05/2024
Permit issued — Construction Fence
X00373307-I1-FN
02/05/2024
Permit issued — Standpipe
X00366016-I1-EW-SD
01/09/2024
Permit issued — Sidewalk Shed
X00492153-I1-SH
12/22/2023
Permit issued — Protection and Mechanical Methods
X00826684-I1-PMM
08/25/2023
Permit issued — Protection and Mechanical Methods
X00515701-I1-PM
08/23/2023
Permit issued — Protection and Mechanical Methods
X00515701-I1-PM
07/18/2023
Permit issued — Supported Scaffold
X00545227-I1-SF
05/23/2023
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments)
Certified
View inspection ↗
05/02/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2023
Special inspection requirement — Post-installed Anchors
JOHN O'CONNOR, P.E.
05/01/2023
Filed — Alteration
INSTALLATION OF CANTLIEVER BEAM SCAFFOLD DURING NEW BUILDING CONTRUCTION FOR WORKER ACCESS. CANTLIEVER BEAM SCAFFOLD IS DESIGNED IN ACCORDANCE WITH NYCC 2014 CHAPTER 33 BUILDING CODE. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
X00606783-P3
05/01/2023
Special inspection requirement — Post-installed Anchors
JOHN O'CONNOR, P.E.
04/27/2023
Permit issued — Supported Scaffold
X00545227-I1-SF
03/27/2023
Filed — Alteration
X00826684-I1
03/27/2023
Permit issued — Protection and Mechanical Methods
X00826684-I1-PMM
02/24/2023
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)
Certified
View inspection ↗
02/02/2023
Permit issued — Protection and Mechanical Methods
X00515701-I1-PM
01/26/2023
Permit issued — Construction Fence
X00373307-I1-FN
01/17/2023
Permit issued — Standpipe
X00366016-I1-EW-SD
01/13/2023
Filed — Alteration
INSTALLATION OF CANTLIEVER BEAM SCAFFOLD DURING NEW BUILDING CONTRUCTION FOR WORKER ACCESS. CANTLIEVER BEAM SCAFFOLD IS DESIGNED IN ACCORDANCE WITH NYCC 2014 CHAPTER 33 BUILDING CODE. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
X00606783-P2
01/12/2023
Filed — Alteration
X00545227-P1
01/11/2023
Permit issued — Sidewalk Shed
X00492153-I1-SH
01/05/2023
Special inspection requirement — Post-installed Anchors
JOHN O'CONNOR, P.E.
12/19/2022
Permit issued — Construction Fence
X00373307-I1-FN
10/17/2022
Permit issued — Protection and Mechanical Methods
X00606783-I1-PM
04/04/2022
Permit issued — Supported Scaffold
X00545227-I1-SF
02/23/2022
Permit issued — Construction Fence
X00373307-I1-FN
10/22/2021
Filed — Alteration
INSTALLATION OF CANTLIEVER BEAM SCAFFOLD DURING NEW BUILDING CONTRUCTION FOR WORKER ACCESS. CANTLIEVER BEAM SCAFFOLD IS DESIGNED IN ACCORDANCE WITH NYCC 2014 CHAPTER 33 BUILDING CODE. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
X00606783-P1
10/15/2021
Permit issued — Protection and Mechanical Methods
X00606783-I1-PM
10/06/2021
Filed — Alteration
INSTALLATION OF CANTLIEVER BEAM SCAFFOLD DURING NEW BUILDING CONTRUCTION FOR WORKER ACCESS. CANTLIEVER BEAM SCAFFOLD IS DESIGNED IN ACCORDANCE WITH NYCC 2014 CHAPTER 33 BUILDING CODE. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
X00606783-I1
06/25/2021
Permit issued — Supported Scaffold
X00545227-I1-SF
06/24/2021
Filed — Alteration
X00545227-I1
05/26/2021
Permit issued — Standpipe
X00366016-I1-EW-SD
05/19/2021
Permit issued — Construction Fence
X00373307-I1-FN
05/11/2021
Filed — Alteration
INSTALLATION OF SINGLE 6000 # CAPACITY PERSONNEL/MATERIAL HOIST DURING NB CONST, FILED SEP. HOIST SHALL COMPLY WITH CH #33 OF THE NYC BC. NO CHANGE IN USE, OCCUPANCY OR EGRESS UNDER THIS APPLICATION. ELEVATOR APPLICATION SUBMITTED SEPARATELY
X00515701-I1
05/11/2021
Permit issued — Protection and Mechanical Methods
X00515701-I1-PM
04/14/2021
Filed — Alteration
X00492153-P2
04/07/2021
Filed — Alteration
X00492153-P1
03/25/2021
Permit issued — Sidewalk Shed
X00492153-I1-SH
03/24/2021
Filed — Alteration
X00492153-I1
02/10/2021
Permit issued — Construction Fence
X00373307-I1-FN
10/15/2020
Signed off — Alteration
installation of 8 ft. high construction fence around the perimeter of the property.
X00231457-I1
10/15/2020
Signed off — Alteration
INSTALLATION OF 8 FT CONSTRUCTION FENCE AROUND THE PERIMETER OF THE PROPERTY.
X00231462-I1
10/15/2020
Signed off — Alteration
INSTALLATION OF CONSTRUCTION FENCE AROUND THE PERIMETER OF THE PROPERTY.
X00231425-I1
09/28/2020
Signed off — Alteration
INSTALL 8 FEET HIGH CONSTRUCTION FENCE AROUND THE PERIMETER OF THE PROPERTY
X00231450-I1
09/21/2020
Filed — Alteration
Proposed structure for 11 story residential building.
X00401514-I1
09/21/2020
Filed — Alteration
Proposed 8' high construction fence at perimeter of property.
X00373307-I1
09/21/2020
Permit issued — Construction Fence
X00373307-I1-FN
09/18/2020
Special inspection requirement — Masonry
SAMI HAJJAR P.E
09/18/2020
Special inspection requirement — Final
Victor Filletti
09/18/2020
Special inspection requirement — Structural Cold-Formed Steel
SAMI HAJJAR P.E
09/18/2020
Special inspection requirement — Concrete - Cast-In-Place
SAMI HAJJAR P.E
07/08/2020
Filed — Alteration
X00366260-I1
07/02/2020
Filed — Alteration
X00366016-I1
06/25/2020
Objection raised — Structural
Latest 60 of 91 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedCLASS ONE CONSTRUCTION LT02/05/2024
DOB NOWStandpipeSigned-offA M B MECHANICAL INC02/05/2024
DOB NOWSidewalk ShedSigned-offRELIABLE ENTERPRISES INC01/09/2024
DOB NOWProtection and Mechanical MethodsSigned-offRELIABLE ENTERPRISES INC12/22/2023
DOB NOWProtection and Mechanical MethodsSigned-offA H INSTALLATION08/25/2023
DOB NOWProtection and Mechanical MethodsSigned-offA H INSTALLATION08/23/2023
DOB NOWSupported ScaffoldSigned-offREPUBLIC EXTERIOR SERVICE07/18/2023
DOB NOWSupported ScaffoldSigned-offREPUBLIC EXTERIOR SERVICE04/27/2023
DOB NOWProtection and Mechanical MethodsSigned-offRELIABLE ENTERPRISES INC03/27/2023
DOB NOWProtection and Mechanical MethodsSigned-offA H INSTALLATION02/02/2023
DOB NOWConstruction FencePermit IssuedCLASS ONE CONSTRUCTION LT01/26/2023
DOB NOWStandpipeSigned-offA M B MECHANICAL INC01/17/2023
DOB NOWSidewalk ShedSigned-offRELIABLE ENTERPRISES INC01/11/2023
DOB NOWConstruction FencePermit IssuedCLASS ONE CONSTRUCTION LT12/19/2022
DOB NOWProtection and Mechanical MethodsSigned-offREPUBLIC EXTERIOR SERVICE10/17/2022
DOB NOWSupported ScaffoldSigned-offREPUBLIC EXTERIOR SERVICE04/04/2022
DOB NOWConstruction FencePermit IssuedCLASS ONE CONSTRUCTION LT02/23/2022
DOB NOWProtection and Mechanical MethodsSigned-offREPUBLIC SCAFFOLD&HOIST C10/15/2021
DOB NOWSupported ScaffoldSigned-offREPUBLIC SCAFFOLD&HOIST C06/25/2021
DOB NOWStandpipeSigned-offUNIVERSAL FIRE SPR LLC05/26/2021
DOB NOWConstruction FencePermit IssuedCLASS ONE CONSTRUCTION LT05/19/2021
DOB NOWProtection and Mechanical MethodsSigned-offA H INSTALLATION05/11/2021
DOB NOWSidewalk ShedSigned-offRELIABLE ENTERPRISES INC03/25/2021
DOB NOWConstruction FencePermit IssuedCLASS ONE CONSTRUCTION LT02/10/2021
DOB NOWConstruction FencePermit IssuedCLASS ONE CONSTRUCTION LT09/21/2020
DOB NOWConstruction FenceSigned-offSANO WRECKING LLC02/21/2020
DOB NOWConstruction FenceSigned-offSANO WRECKING LLC10/18/2019
DOB NOWConstruction FenceSigned-offSANO WRECKING LLC10/07/2019
BIS—ISSUEDCLASS ONE CONSTRUCTION LT01/07/2025
BIS—ISSUEDCLASS ONE CONSTRUCTION LT08/08/2024
BIS—ISSUEDCLASS ONE CONSTRUCTION LT07/09/2024
BIS—ISSUEDCLASS ONE CONSTRUCTION LT07/02/2024
BISPLISSUEDROCK E SMALL PLBG&HTG INC02/05/2024
BIS—ISSUEDCLASS ONE CONSTRUCTION LT10/31/2023
BIS—ISSUEDCLASS ONE CONSTRUCTION LT05/26/2023
BISPLISSUEDROCK E SMALL PLBG&HTG INC01/18/2023
BIS—ISSUEDCLASS ONE CONSTRUCTION LT01/13/2023
BIS—ISSUEDCLASS ONE CONSTRUCTION LT12/27/2022
BIS—ISSUEDCLASS ONE CONSTRUCTION LT02/22/2022
BISPLISSUEDWATERMARK PLUMBING CORP01/14/2021
+ 4 more permits on file
4 projects · most recent 06/21/2021
General Wiring
FiledStatusContractorScope
06/21/2021Permit IssuedWCK ELECTRIC CORP.General Wiring
05/12/2021CompleteRICHARD NEU—
03/30/2021CompleteRICHARD NEU—
03/29/2021Permit IssuedWCK ELECTRIC CORP.General Wiring
1 project · most recent 09/21/2020
Concrete
FiledStatusContractorScope
09/21/2020——Concrete
1 project · most recent 09/21/2020
Fence
FiledStatusContractorScope
09/21/2020Permit IssuedCLASS ONE CONSTRUCTION LTFence
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
05/23/2023Certified StandPipe - SD - Hydrostatic 63/09 Test (100 Foot Increments)CertifiedView ↗
02/24/2023Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
05/02/2023Post-installed AnchorsJOHN O'CONNOR, P.E.special
05/01/2023Post-installed AnchorsJOHN O'CONNOR, P.E.special
01/05/2023Post-installed AnchorsJOHN O'CONNOR, P.E.special
09/18/2020MasonrySAMI HAJJAR P.Especial
09/18/2020FinalVictor Fillettiprogress
09/18/2020Structural Cold-Formed SteelSAMI HAJJAR P.Especial
09/18/2020Concrete - Cast-In-PlaceSAMI HAJJAR P.Especial
06/19/2020Standpipe Systems—special
09/19/2019FinalVICTOR GORDONprogress
09/19/2019FinalVICTOR GORDONprogress
09/19/2019FinalVICTOR GORDONprogress
09/19/2019FinalVICTOR GORDONprogress
▾Documents — 213 on file (BIS + DOB NOW)
▸Plans & Drawings21
▸DOB NOWPlans/Sketch11
08/25/2026X00492153-P2Request digital key ↗
08/25/2026X00492153-I1Request digital key ↗
08/25/2026X00492153-P1Request digital key ↗
Showing 3 of 11 on file for this type
▸DOB NOWPlans/Sketch - Construction Fence6
08/26/2026X00231425-I1Request digital key ↗
08/26/2026X00231457-I1Request digital key ↗
08/26/2026X00231462-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸DOB NOWPlans/Sketch - Structural2
08/26/2026X00401514-I1Request digital key ↗
08/15/2026X00401514-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Standpipe2
08/26/2026X00360524-I1Request digital key ↗
08/26/2026X00366016-I1Request digital key ↗
▸Applications & Permits31
▸BISPLAN / WORK APPROVAL APPLICATION15
01/14/2025220696432Open ↗
12/09/2024220696432Open ↗
12/03/2024220696432Open ↗
Showing 3 of 15 on file for this type
▸BISWORK PERMIT APPLICATION13
10/28/2024220696432Open ↗
07/15/2024220696432Open ↗
11/02/2023220696432Open ↗
Showing 3 of 13 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation2
03/13/2024220715581Open ↗
09/23/2019220715581Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
12/17/2024220696432Open ↗
▸Zoning, Tax Lot & Property Records4
▸BISZONING DIAGRAM2
11/21/2019220696432Open ↗
11/19/2019220696432Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
03/13/2024220715581Open ↗
▸BISFLOOD ZONE COMPLIANCE1
07/13/2020220696432Open ↗
▸Seals & Professional Certifications41
▸DOB NOWDPL-1: Design Professional Seal & Signature21
08/26/2026X00231425-I1Open ↗
08/26/2026X00231457-I1Open ↗
08/26/2026X00231462-I1Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/27/2026X00231450-I1Open ↗
09/14/2026X00401514-I1Open ↗
08/29/2026X00231425-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/14/2026X00401514-I1Open ↗
09/14/2026X00401514-I1Open ↗
09/14/2026X00401514-I1Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
09/24/2020240286793Open ↗
06/18/2020240275340Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
09/24/2020240286793Open ↗
06/18/2020240275340Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
09/24/2020240286793Open ↗
06/18/2020240275340Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
02/27/2020220711004Open ↗
04/08/2019220696432Open ↗
▸Trade Schedules & Equipment7
▸BISSCHEDULE B - PLUMBING2
01/14/2025220696432Open ↗
05/27/2021220696432Open ↗
▸BISHVAC & SERVICE WATER HEATING SYSTEM CONTROLS1
01/21/2025220696432Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
04/08/2019220696432Open ↗
▸BISSPRINKLER SYSTEMS1
11/20/2024220696432Open ↗
▸BISPROVIDE HYDRAULIC CALCS FOR STANDPIPESYSTEM SIGNED AND SEALED1
07/27/2020220696432Open ↗
▸BISSTANDPIPE SYSTEMS1
12/16/2024220696432Open ↗
▸Safety & Tenant Protection6
▸BISSTREET TREE CHECKLIST3
03/13/2024220715581Open ↗
09/23/2019220715581Open ↗
04/08/2019220696432Open ↗
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
07/06/2020220696432Open ↗
▸BISBPP: STREET TREES SITE PLAN1
03/13/2024220715581Open ↗
▸BISSRO MD ANTI-HARASSMENT CHECKLIST1
02/27/2020220711004Open ↗
▸Energy Compliance12
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
07/06/2020220696432Open ↗
06/18/2020240275340Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
01/21/2025220696432Open ↗
▸BISFENESTRATION AREAS1
01/21/2025220696432Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
01/21/2025220696432Open ↗
▸BISLIGHTING IN DWELLING UNITS1
01/21/2025220696432Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
01/21/2025220696432Open ↗
▸BISELECTRIC MOTORS1
01/21/2025220696432Open ↗
▸BISLIGHTING CONTROLS1
01/21/2025220696432Open ↗
▸BIS* HVAC INSULATION AND SEALING1
01/21/2025220696432Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
04/08/2019220696432Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
01/21/2025220696432Open ↗
▸Inspections & Test Reports19
▸BISTECHNICAL REPORT: RESPONSIBILITY6
02/03/2021220696432Open ↗
09/24/2020240286793Open ↗
07/06/2020220696432Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX3
02/08/2023220696432Open ↗
02/16/2021220696432Open ↗
07/06/2020220696432Open ↗
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
07/06/2020220696432Open ↗
07/06/2020220696432Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
01/21/2025220696432Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
01/21/2025220696432Open ↗
▸BISFOOTING AND FOUNDATION INSPECTION1
01/21/2025220696432Open ↗
▸BISMASONRY1
01/21/2025220696432Open ↗
▸BISDIR-14 ID OF RESPONSIBILITY (TR1)1
07/02/2020240275340Open ↗
▸BISHYDRO FLOW TEST LETTER1
11/18/2019220696432Open ↗
▸BISSOIL REPORT1
09/24/2020240286793Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
10/03/2019220696432Open ↗
▸Approvals, Objections & Sign-offs26
▸BISLETTERS - SUPPORTING DOCUMENTATION14
05/13/2021220696432Open ↗
05/13/2021220696432Open ↗
09/18/2020220696432Open ↗
Showing 3 of 14 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE7
12/09/2024220696432Open ↗
12/03/2024220696432Open ↗
02/03/2021220696432Open ↗
Showing 3 of 7 on file for this type
▸BISSUPERSEDING LETTER5
07/15/2024220696432Open ↗
07/03/2024220696432Open ↗
11/02/2023220696432Open ↗
Showing 3 of 5 on file for this type
▸Cost, Insurance & Ownership7
▸BISPROJECT-SPECIFIC GL INSURANCE4
10/31/2023220696432Open ↗
01/13/2023220696432Open ↗
12/29/2022220696432Open ↗
Showing 3 of 4 on file for this type
▸BISCOST AFFIDAVIT2
09/24/2020240286793Open ↗
06/18/2020240275340Open ↗
▸BISINSURANCE: LIABILITY1
10/30/2024220715581Open ↗
▸Filing & Intake Forms11
▸BISBOROUGH INTAKE FORM4
01/13/2023220696432Open ↗
12/29/2022220696432Open ↗
05/13/2021220696432Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING COVER SHEET3
09/23/2019220715581Open ↗
07/23/2019220711004Open ↗
04/08/2019220696432Open ↗
▸BISADDITIONAL INFORMATION2
12/03/2024220696432Open ↗
05/27/2021220696432Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
09/24/2020240286793Open ↗
06/18/2020240275340Open ↗
▸Other Documents8
▸BISBPP - SUPPORTING DOCUMENTATION2
03/13/2024220715581Open ↗
03/13/2024220715581Open ↗
▸BISPROVIDE REQUIRED EXHIBITS AND INDICATECRFN NUMBERS ON PW1 LINE 9 AND SCHEDULEA NOTES SECT1
07/13/2020220696432Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
03/13/2024220715581Open ↗
▸BISVESTIBULES1
01/21/2025220696432Open ↗
▸BISMAINTENANCE INFORMATION1
01/21/2025220696432Open ↗
▸BISPROTECTION OF EXPOSED FOUNDATION INSULATION1
01/21/2025220696432Open ↗
▸BISPLOT DIAGRAM1
04/08/2019220696432Open ↗