← Back
Two family brick
317 95 STREET
BROOKLYN · Bay Ridge · BIN 3155511
💬 Discuss this project
1915Year Built
2Stories
B1Building Class
R5BZoning
1,952 sfGross Floor Area
2Units
1 Open Violation 0 unresolved · 1 paperwork only ▸
Two family brick · 2,000 sf lot · 0.98 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
CellarUnder Construction5p · 1 filing · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
VKW DESIGN308/29/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VKW DESIGN INC206/01/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CUBE BUILD GROUPSGeneral Contractor107/14/2026
GREGG NY PLUMBING, INCPlumbing107/10/2026
Building Lifecycle
All (26)Filed (2)Permit Issued (2)Violation (3)Inspection (6)Objection (2)Special Inspection (11)
09/08/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/13/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/13/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/30/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/30/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/28/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/13/2026
Permit issued — General Construction
B01409823-I1-GC
07/08/2026
Permit issued — Plumbing
B01409823-S1-PL
06/08/2026
Objection resolved — Addressed
06/04/2026
Objection raised — Other
06/01/2026
Filed — Alteration
PROPOSED CONSTRUCTION RENOVATION AT CELLAR FILED TO ADDRESS ECB VIOLATION 39188583L AND 39188584N. WORK AS PER PLAN. NO CHANGE TO USE, EGRESS, OR OCCUPANCY. NO CHANGE TO BUILDING ENVELOPE OF FLOOR AREA
B01409823-I1
06/01/2026
Filed — Alteration
PROPOSED CONSTRUCTION RENOVATION AT CELLAR FILED TO ADDRESS ECB VIOLATION 39188583L AND 39188584N. WORK AS PER PLAN. NO CHANGE TO USE, EGRESS, OR OCCUPANCY. NO CHANGE TO BUILDING ENVELOPE OF FLOOR AREA
B01409823-S1
06/01/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Yuxuan Liu
06/01/2026
Special inspection requirement — Tenant Protection Plan Compliance
Yuxuan Liu
06/01/2026
Special inspection requirement — Energy Code Compliance Inspections
Yuxuan Liu
06/01/2026
Special inspection requirement — Fire-Resistance Rated Construction
Yuxuan Liu
06/01/2026
Special inspection requirement — Interior lighting power
Yuxuan Liu
06/01/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Yuxuan Liu
06/01/2026
Special inspection requirement — Tenant Protection Plan Compliance
Yuxuan Liu
06/01/2026
Special inspection requirement — Energy Code Compliance Inspections
Yuxuan Liu
06/01/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Yuxuan Liu
06/01/2026
Special inspection requirement — HVAC-R and service water heating equipment
Yuxuan Liu
06/01/2026
Special inspection requirement — HVAC-R and service water heating system controls
Yuxuan Liu
05/14/2026
Violation issued (ECB, closed)
Construction
05/14/2026
Violation issued (ECB, closed)
Unknown
05/14/2026
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedCUBE BUILD GROUPS INC07/13/2026
DOB NOWPlumbingPermit IssuedGREGG NY PLUMBING, INC07/08/2026
1 project · most recent 06/01/2026
Gas Water/Sanitary
FiledStatusContractorScope
06/01/2026Permit IssuedGREGG NY PLUMBING, INCGas, Water/Sanitary
1 project · most recent 06/01/2026
General Wiring
FiledStatusContractorScope
06/01/2026Permit IssuedJ Y ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
09/08/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/13/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/13/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/30/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/30/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/28/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
06/01/2026Fire-Resistant Penetrations and JointsYuxuan Liuspecial
06/01/2026Tenant Protection Plan ComplianceYuxuan Liuspecial
06/01/2026Energy Code Compliance InspectionsYuxuan Liuprogress
06/01/2026Fire-Resistance Rated ConstructionYuxuan Liuprogress
06/01/2026Interior lighting powerYuxuan Liuenergy_progress
06/01/2026Fire-Resistant Penetrations and JointsYuxuan Liuspecial
06/01/2026Tenant Protection Plan ComplianceYuxuan Liuspecial
06/01/2026Energy Code Compliance InspectionsYuxuan Liuprogress
06/01/2026HVAC-R and service water piping design and insulationYuxuan Liuenergy_progress
06/01/2026HVAC-R and service water heating equipmentYuxuan Liuenergy_progress
06/01/2026HVAC-R and service water heating system controlsYuxuan Liuenergy_progress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/16/2026B01409823-S1Request digital key ↗
08/15/2026B01409823-I1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature5
08/29/2026B01409823-I1Open ↗
08/29/2026B01409823-I1Open ↗
08/29/2026B01409823-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/29/2026B01409823-I1Open ↗
08/29/2026B01409823-I1Open ↗
08/25/2026B01409823-S1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/16/2026B01409823-I1Open ↗
08/16/2026B01409823-S1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/16/2026B01409823-S1Open ↗
08/15/2026B01409823-I1Open ↗