← Back
BuildNYC
Two stories - detached, small or mid-size
3187 PARSIFAL PLACE
BRONX · BIN 2075244
💬 Discuss this project
1940Year Built
2Stories
A1Building Class
R3AZoning
1,280 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,120 sf lot · 0.6 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 213p · 1 filing · 20 docs
Floor 112p · 1 filing · 20 docs
Cellar12p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/22/2022$550K—Private party → Private party$430/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Gino O. Longo, Architect401/17/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JS Concrete & Masonryspecialty_contractor303/21/2026
Empire Electric NYCElectrical203/22/2026
New Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Gino O. Longo Architetct331401/17/2024
Building Lifecycle
02/15/2024
Signed off — Alteration
APPLICATION HEREWITH FILED FOR PROPOSED MINOR GUT-REHAB OF EXISTING ONE-FAMILY DWELLING. NO CHANGE IN OCCUPANCY, USE, OR EGRESS. NO CHANGE IN BULK.
X00801451-I1
02/15/2024
Signed off — Alteration
APPLICATION HEREWITH FILED FOR PROPOSED MINOR GUT-REHAB OF EXISTING ONE-FAMILY DWELLING. NO CHANGE IN OCCUPANCY, USE, OR EGRESS. NO CHANGE IN BULK.
X00801451-S1
02/07/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
02/06/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
GINO LONGO
02/06/2024
Special inspection requirement — Fire-Resistance Rated Construction
GINO LONGO
34 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offNew Plumbing & Heating05/02/2023
DOB NOWGeneral ConstructionSigned-offJS Concrete & Masonry03/31/2023
1 project · most recent 10/23/2023
General Wiring
FiledStatusContractorScope
10/23/2023Permit IssuedEmpire Electric NYCGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
02/07/2024Pass-Final General Construction Non-Directive 14PassView ↗
10/17/2023Fail-Final General Construction Non-Directive 14FailView ↗
10/16/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/09/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/09/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/24/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
02/06/2024Fire-Resistant Penetrations and JointsGINO LONGOspecial
02/06/2024Fire-Resistance Rated ConstructionGINO LONGOprogress
02/06/2024Energy Code Compliance InspectionsGINO LONGOprogress
02/06/2024Fenestration air leakageGINO LONGOenergy_progress
02/06/2024Fenestration and door U-factor and product ratingsGINO LONGOenergy_progress
02/06/2024Fenestration areasGINO LONGOenergy_progress
02/06/2024Air barrier - visual inspectionGINO LONGOenergy_progress
12/26/2023Fire-Resistant Penetrations and JointsGINO LONGOspecial
12/26/2023Energy Code Compliance InspectionsGINO LONGOprogress
12/26/2023Fire-Resistance Rated ConstructionGINO LONGOprogress
12/26/2023Fenestration air leakageGINO LONGOenergy_progress
12/26/2023Fenestration areasGINO LONGOenergy_progress
12/26/2023Air barrier - visual inspectionGINO LONGOenergy_progress
12/26/2023Fenestration and door U-factor and product ratingsGINO LONGOenergy_progress
07/28/2023Fire-Resistant Penetrations and JointsGINO LONGOspecial
07/28/2023Energy Code Compliance InspectionsGINO LONGOprogress
28 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account