← Back
Primarily 2 family with 1 store or office
32-03 31 AVENUE
QUEENS · BIN 4008586
💬 Discuss this project
1931Year Built
3Stories
S2Building Class
R6AZoning
4,400 sfGross Floor Area
3Units
Rent Stabilized0 Open Violations
Primarily 2 family with 1 store or office · 1,200 sf lot · 3.67 FAR built · Flood zone X
Locations of Work
Mechanical
Floor 12p · 1 filing · 16 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ORPHEUS ASSOCIATES101/31/2024
ALBERTO ROMAN212/30/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUPERIOR FIRE CONTROL203/21/2026
ACS ENVIRONMENTAL CONSTRUCTION203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUPERIOR FIRE CONTROL INCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AR-TECH ENGINEERING, P.C.6659212/30/2019
Building Lifecycle
All (28)Filed (3)Permit Issued (1)Violation (15)Special Inspection (9)
01/31/2024
Filed — Alteration
Q00994244-I1
01/22/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
12/04/2023
Violation issued (HPD, closed)
I
12/03/2023
Violation issued (HPD, closed)
C
12/03/2023
Violation issued (HPD, closed)
C
12/03/2023
Violation issued (HPD, closed)
A
12/03/2023
Violation issued (HPD, closed)
B
12/03/2023
Violation issued (HPD, closed)
B
12/31/2019
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALBERTO ROMAN
12/31/2019
Special inspection requirement — Final
ALBERTO ROMAN
12/31/2019
Special inspection requirement — Duct leakage testing
ALBERTO ROMAN
12/31/2019
Special inspection requirement — Mechanical Systems
ALBERTO ROMAN
12/30/2019
Filed — Alteration
INSTALL THE KITCHEN EXHAUST SYSTEM S/S DUCT TO THE ROF FOR COMMERCIAL SPACE.
Q00269649-P1
12/30/2019
Special inspection requirement — Mechanical Systems
ALBERTO ROMAN
12/30/2019
Special inspection requirement — Final
ALBERTO ROMAN
12/30/2019
Special inspection requirement — Duct leakage testing
ALBERTO ROMAN
12/30/2019
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALBERTO ROMAN
12/23/2019
Permit issued — Mechanical Systems
Q00269649-I1-MS
12/18/2019
Filed — Alteration
INSTALL THE KITCHEN EXHAUST SYSTEM S/S DUCT TO THE ROF FOR COMMERCIAL SPACE.
Q00269649-I1
04/06/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/18/2015
Violation issued (HPD, closed)
B
12/18/2015
Violation issued (HPD, closed)
B
11/05/2015
Violation issued (ECB, closed)
Construction
10/01/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedSUPERIOR FIRE CONTROL INC12/23/2019
BISFPISSUEDMASTER FIRE SYSTEMS, INC12/29/2015
1 project · most recent 12/30/2019
Others
FiledStatusContractorScopeMake / Model / Capacity
12/30/2019Permit IssuedSUPERIOR FIRE CONTROL INCOthers
Other
Pen Vent USB118DD 5,600 CFM · Kitchen Exhaust ×2
2 projects · most recent 05/23/2018
General Wiring
FiledStatusContractorScope
05/23/2018CompleteACG ELEC'L CONTR'S INC.General Wiring
05/23/2018Permit IssuedACG ELEC'L CONTR'S INC.4 meters, 4 new_meters
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
01/22/2024Fire-Resistant Penetrations and Joints—special
12/31/2019Fire-Resistant Penetrations and JointsALBERTO ROMANspecial
12/31/2019FinalALBERTO ROMANprogress
12/31/2019Duct leakage testing ALBERTO ROMANenergy_progress
12/31/2019Mechanical SystemsALBERTO ROMANspecial
12/30/2019Mechanical SystemsALBERTO ROMANspecial
12/30/2019FinalALBERTO ROMANprogress
12/30/2019Duct leakage testing ALBERTO ROMANenergy_progress
12/30/2019Fire-Resistant Penetrations and JointsALBERTO ROMANspecial
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Mechanical Systems2
08/28/2026Q00269649-I1Request digital key ↗
08/15/2026Q00269649-P1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/23/2026Q00994244-I1Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION2
11/14/2019421907609Open ↗
12/12/2015421189458Open ↗
▸BISWORK PERMIT APPLICATION2
11/14/2019421907609Open ↗
12/30/2015421189458Open ↗
▸Seals & Professional Certifications18
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026Q00269649-P1Open ↗
09/01/2026Q00269649-P1Open ↗
08/27/2026Q00269649-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026Q00269649-P1Open ↗
09/01/2026Q00269649-P1Open ↗
08/27/2026Q00269649-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
11/14/2019421907609Open ↗
12/30/2015421189458Open ↗
12/12/2015421189458Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/28/2026Q00269649-I1Open ↗
08/23/2026Q00994244-I1Open ↗
08/13/2026Q00269649-P1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
11/14/2019421907609Open ↗
12/12/2015421189458Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
11/14/2019421907609Open ↗
12/12/2015421189458Open ↗
▸Safety & Tenant Protection3
▸DOB NOWTenant Protection Plan2
08/28/2026Q00269649-I1Open ↗
08/13/2026Q00269649-P1Open ↗
▸BISTenant Protection Plan and Notes1
11/14/2019421907609Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/28/2026Q00269649-I1Open ↗
08/23/2026Q00994244-I1Open ↗
08/13/2026Q00269649-P1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/14/2019421907609Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
11/14/2019421907609Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
11/14/2019421907609Open ↗
12/12/2015421189458Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
11/14/2019421907609Open ↗
12/12/2015421189458Open ↗