← Back
One family attached or semi-detached
32-53 87 STREET
QUEENS · BIN 4034814
💬 Discuss this project
1925Year Built
2Stories
A5Building Class
R4Zoning
1,480 sfGross Floor Area
1Units
One family attached or semi-detached · 1,840 sf lot · 0.8 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
URENA CONSTRUCTION & DESIGN1007/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FANG ARCHITECT309/06/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
URENA CONST & DESIGN INCGeneral Contractor207/08/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FANG ARCHITECT5513309/06/2022
Building Lifecycle
All (23)Filed (3)Permit Issued (3)Signed Off (1)Inspection (8)Special Inspection (8)
10/24/2022
Signed off — Alteration
INTERIOR RENOVATION FOR 1-FAMILY BUILDING, NO CHANGE EGRESS, IN USE OR OCCUPANCY.
Q00651822-I1
10/20/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
09/28/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/13/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/06/2022
Filed — Alteration
INTERIOR RENOVATION FOR 1-FAMILY BUILDING, NO CHANGE EGRESS, IN USE OR OCCUPANCY.
Q00651822-P1
09/06/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
DEZHANG FANG
09/06/2022
Special inspection requirement — Energy Code Compliance Inspections
DEZHANG FANG
09/06/2022
Special inspection requirement — Fire-Resistance Rated Construction
DEZHANG FANG
09/06/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
DEZHANG FANG
09/06/2022
Special inspection requirement — Fenestration air leakage
DEZHANG FANG
09/06/2022
Special inspection requirement — Insulation placement and R values
DEZHANG FANG
09/06/2022
Special inspection requirement — Fenestration areas
DEZHANG FANG
09/06/2022
Special inspection requirement — Interior lighting power
DEZHANG FANG
08/08/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/22/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/16/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/16/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/16/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/09/2022
Permit issued — Plumbing
Q00651904-I1-PL
02/28/2022
Filed — Alteration
FILED PLUMBING WORK FOR 1-FAMILY DWELLING.
Q00651904-I1
02/08/2022
Permit issued — General Construction
Q00651822-I1-GC
01/12/2022
Permit issued — General Construction
Q00651822-I1-GC
01/04/2022
Filed — Alteration
INTERIOR RENOVATION FOR 1-FAMILY BUILDING, NO CHANGE EGRESS, IN USE OR OCCUPANCY.
Q00651822-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR03/09/2022
DOB NOWGeneral ConstructionSigned-offURENA CONST & DESIGN INC02/08/2022
DOB NOWGeneral ConstructionSigned-offURENA CONST & DESIGN INC01/12/2022
1 project · most recent 02/28/2022
Gas Water/Sanitary
FiledStatusContractorScope
02/28/2022Signed-offINFINITI ESC PLUMBING CORGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
10/20/2022Pass-Final General Construction Non-Directive 14PassView ↗
09/28/2022Fail-Final General Construction Non-Directive 14FailView ↗
09/13/2022Fail-Final General Construction Non-Directive 14FailView ↗
08/08/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/22/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/16/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/16/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/16/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
09/06/2022Fire-Resistant Penetrations and JointsDEZHANG FANGspecial
09/06/2022Energy Code Compliance InspectionsDEZHANG FANGprogress
09/06/2022Fire-Resistance Rated ConstructionDEZHANG FANGprogress
09/06/2022Fenestration and door U-factor and product ratingsDEZHANG FANGenergy_progress
09/06/2022Fenestration air leakageDEZHANG FANGenergy_progress
09/06/2022Insulation placement and R valuesDEZHANG FANGenergy_progress
09/06/2022Fenestration areasDEZHANG FANGenergy_progress
09/06/2022Interior lighting powerDEZHANG FANGenergy_progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/26/2026Q00651904-I1Request digital key ↗
08/25/2026Q00651822-P1Request digital key ↗
08/25/2026Q00651822-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/25/2026Q00651822-P1Open ↗
08/25/2026Q00651822-I1Open ↗
08/13/2026Q00651904-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/22/2026Q00651822-P1Open ↗
08/22/2026Q00651822-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026Q00651822-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/25/2026Q00651822-P1Open ↗
08/25/2026Q00651822-I1Open ↗
08/13/2026Q00651904-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026Q00651822-I1Open ↗