| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 09/22/2021 | $995K | — | — → — | $513/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| FLUSHING ENGINEERING SERVICE PC | 4 | 07/12/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| M2 DESIGN | 8 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| RONG MAINTENANCE INC | General Contractor | 1 | 07/08/2026 |
| CATMAN PLUMBING INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| FLUSHING ENGINEERING SERV | 4373 | 4 | 07/12/2022 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Signed-off | RONG MAINTENANCE INC | 11/16/2021 |
| DOB NOW | Plumbing | Signed-off | CATMAN PLUMBING INC | 11/15/2021 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/08/2022 | Complete | FIRST STAR ELECTRIC INC | 5 meters, 5 new_meters |
| Date | Type | Result | Report |
|---|---|---|---|
| 08/15/2022 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 08/11/2022 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 08/09/2022 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 06/13/2022 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 06/13/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 06/13/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/12/2022 | Structural Stability – Alterations of existing buildings | KY FU | special |
| 07/12/2022 | Fire-Resistant Penetrations and Joints | KY FU | special |
| 07/12/2022 | Lighting in dwelling units | KY FU | energy_progress |
| 07/12/2022 | HVAC-R and service water piping design and insulation | KY FU | energy_progress |
| 05/24/2022 | Fire-Resistant Penetrations and Joints | KY FU | special |
| 05/24/2022 | HVAC-R and service water piping design and insulation | KY FU | energy_progress |
| 05/24/2022 | Energy Code Compliance Inspections | KY FU | progress |
| 05/24/2022 | HVAC-R and service water heating system controls | KY FU | energy_progress |
| 05/24/2022 | HVAC-R and service water heating equipment | KY FU | energy_progress |
| 05/13/2022 | HVAC-R and service water piping design and insulation | KY FU | energy_progress |
| 05/13/2022 | Energy Code Compliance Inspections | KY FU | progress |
| 05/13/2022 | HVAC-R and service water heating equipment | KY FU | energy_progress |
| 05/13/2022 | HVAC-R and service water heating system controls | KY FU | energy_progress |
| 05/13/2022 | HVAC-R and service water piping design and insulation | KY FU | energy_progress |
| 05/13/2022 | Fire-Resistant Penetrations and Joints | KY FU | special |
| 05/13/2022 | Structural Stability – Alterations of existing buildings | KY FU | special |
| 05/13/2022 | Lighting in dwelling units | KY FU | energy_progress |
| 05/13/2022 | Fire-Resistant Penetrations and Joints | KY FU | special |